Akses terbuka
Jurnal
SINTA 1
Visualizing the velocity fields and fluid behavior of a solution using artificial intelligence during EndoActivator activation
Dental Journal (Majalah Kedokteran Gigi) · Vol. 55 No. 3 (2022) · hlm. 125–129
ISSN 2442-9740, 1978-3728
Terbit 2022-09-01
Penerbit Faculty of Dental Medicine, Universitas Airlangga https://fkg.unair.ac.id/en
Bahasa eng
Abstrak
Background: Electrical devices driven sonically have been found in several studies to be effective to clean root canals but the effect of the EndoActivator irrigant activation flow behavior on cleaning efficacy is not completely understood. Purpose: The study aimed to provide an initial understanding of flow behavior and velocity field generation during the irrigant activation process by EndoActivator using artificial intelligence (AI). Methods: A straight glass model was filled with a solution containing 17% EDTA. Meanwhile, a medium activator tip with 22-mm polymer noncutting #25, 0.04 file driven by an electrical sonic hand-piece at 190 Hz (highest level) was used to induce velocity field to produce micro-bubbles. The physical mechanisms involved were recorded using a Miro 320S highspeed imaging system, the hydrodynamic responses were recorded, and analyzed using a motion estimation program supported by LiteFlowNet (AI). Results: The rapid fluid flow was visualized clearly in the model when it was activated by an EndoActivator tip. It was also observed that the distal end of the EndoActivator tip generated a near-wall high gradient velocity apically in all directions of the oscillation. Conclusion: The analysis showed that the proposed motion estimation program, supported by LiteFlowNet (AI), was able to capture velocity magnitude estimation of a non-PIV experiment and visualize the bubbles generated in the solution.
Jaringan kolaborasi para penulis
10 penulis ·
18 tautan kepenulisan bersama
· 7 lintas organisasi
Arahkan kursor atau ketuk sebuah nama untuk menyorot rekan penulisnya. Klik dua kali untuk membuka halaman penulis.
Bandung Institute of Technology Universitas Airlangga Maranatha Christian University Keio University Afiliasi tidak diketahui
Organisasi berbeda
Organisasi sama
Afiliasi tidak diketahui
Garis lebih tebal = lebih banyak artikel bersama · lingkaran lebih besar = lebih banyak artikel
Tampilkan sebagai tabel
Afiliasi berasal dari OpenAlex; metadata OAI-PMH jurnal tidak memuatnya. Penulis tanpa ID OpenAlex dicocokkan berdasarkan nama, sehingga dua orang bisa tergabung atau satu orang bisa terpisah.
Sumber metadata: OAI-PMH (metadata jurnal) https://e-journal.unair.ac.id/MKG/oai, pertama di-harvest 8 Nov 2026, terakhir terlihat 8 Nov 2026.
Metadata asli (oai_dc)
<oai_dc:dc xmlns="http://www.openarchives.org/OAI/2.0/" xmlns:dc="http://purl.org/dc/elements/1.1/" xmlns:oai_dc="http://www.openarchives.org/OAI/2.0/oai_dc/" xmlns:xsi="http://www.w3.org/2001/XMLSchema-instance" xsi:schemaLocation="http://www.openarchives.org/OAI/2.0/oai_dc/ http://www.openarchives.org/OAI/2.0/oai_dc.xsd">
<dc:title xml:lang="en-US">Visualizing the velocity fields and fluid behavior of a solution using artificial intelligence during EndoActivator activation</dc:title>
<dc:creator>Peeters, Harry Huiz</dc:creator>
<dc:creator>Judith, Elvira Theola</dc:creator>
<dc:creator>Silitonga, Faber Yosua</dc:creator>
<dc:creator>Zuhal, Lavi Rizki</dc:creator>
<dc:subject xml:lang="en-US">artificial intelligence</dc:subject>
<dc:subject xml:lang="en-US">EndoActivator</dc:subject>
<dc:subject xml:lang="en-US">endodontics</dc:subject>
<dc:subject xml:lang="en-US">natural frequency</dc:subject>
<dc:subject xml:lang="en-US">shear stress</dc:subject>
<dc:description xml:lang="en-US">Background: Electrical devices driven sonically have been found in several studies to be effective to clean root canals but the effect of the EndoActivator irrigant activation flow behavior on cleaning efficacy is not completely understood. Purpose: The study aimed to provide an initial understanding of flow behavior and velocity field generation during the irrigant activation process by EndoActivator using artificial intelligence (AI). Methods: A straight glass model was filled with a solution containing 17% EDTA. Meanwhile, a medium activator tip with 22-mm polymer noncutting #25, 0.04 file driven by an electrical sonic hand-piece at 190 Hz (highest level) was used to induce velocity field to produce micro-bubbles. The physical mechanisms involved were recorded using a Miro 320S highspeed imaging system, the hydrodynamic responses were recorded, and analyzed using a motion estimation program supported by LiteFlowNet (AI). Results: The rapid fluid flow was visualized clearly in the model when it was activated by an EndoActivator tip. It was also observed that the distal end of the EndoActivator tip generated a near-wall high gradient velocity apically in all directions of the oscillation. Conclusion: The analysis showed that the proposed motion estimation program, supported by LiteFlowNet (AI), was able to capture velocity magnitude estimation of a non-PIV experiment and visualize the bubbles generated in the solution. </dc:description>
<dc:publisher xml:lang="en-US">Faculty of Dental Medicine, Universitas Airlangga https://fkg.unair.ac.id/en</dc:publisher>
<dc:date>2022-09-01</dc:date>
<dc:type>info:eu-repo/semantics/article</dc:type>
<dc:type>info:eu-repo/semantics/publishedVersion</dc:type>
<dc:format>text/xml</dc:format>
<dc:format>application/pdf</dc:format>
<dc:identifier>https://e-journal.unair.ac.id/MKG/article/view/33762</dc:identifier>
<dc:identifier>10.20473/j.djmkg.v55.i3.p125-129</dc:identifier>
<dc:source xml:lang="en-US">Dental Journal (Majalah Kedokteran Gigi); Vol. 55 No. 3 (2022): September 2022; 125-129</dc:source>
<dc:source>2442-9740</dc:source>
<dc:source>1978-3728</dc:source>
<dc:language>eng</dc:language>
<dc:relation>https://e-journal.unair.ac.id/MKG/article/view/33762/40045</dc:relation>
<dc:relation>https://e-journal.unair.ac.id/MKG/article/view/33762/22203</dc:relation>
<dc:rights xml:lang="en-US">Copyright (c) 2022 Dental Journal (Majalah Kedokteran Gigi)</dc:rights>
<dc:rights xml:lang="en-US">https://creativecommons.org/licenses/by-sa/4.0</dc:rights>
</oai_dc:dc>
Sitasi dan pengindeksan
Jumlah menurut tiap indeks pada 13 Nov 2026; setiap indeks menghitung sitasi dengan cara berbeda.
OpenAlex juga mencatat karya ini di: crossref, doaj.
Sitasi artikel ini
APA 7
Peeters, H. H., Judith, E. T., Silitonga, F. Y., & Zuhal, L. R. (2022). Visualizing the velocity fields and fluid behavior of a solution using artificial intelligence during EndoActivator activation. Dental Journal (Majalah Kedokteran Gigi), 55(3), 125–129. https://doi.org/10.20473/j.djmkg.v55.i3.p125-129
Salin
IEEE
H. H. Peeters, E. T. Judith, F. Y. Silitonga, and L. R. Zuhal, “Visualizing the velocity fields and fluid behavior of a solution using artificial intelligence during EndoActivator activation,” Dental Journal (Majalah Kedokteran Gigi), vol. 55, no. 3, pp. 125–129, 2022, doi: 10.20473/j.djmkg.v55.i3.p125-129.
Salin
Dibuat dari metadata jurnal; periksa nama penulis sebelum dipakai.