Melola Discovery

← Melola Discovery

Akses terbuka Jurnal SINTA 1

Reinforcing three-dimensional self-reinforcing self-etch adhesive and surface conditioning in immediate dentin sealing of composite resin–dentin

Dental Journal (Majalah Kedokteran Gigi) · Vol. 59 No. 2 (2026) · hlm. 141–147

DOI
10.20473/j.djmkg.v59.i2.p141-147
ISSN
2442-9740, 1978-3728
Terbit
2026-04-30
Penerbit
Faculty of Dental Medicine, Universitas Airlangga https://fkg.unair.ac.id/en
Bahasa
eng
Lisensi
creativecommons.org/licenses/by-sa/4.0

Abstrak

Background: Exposed dentin must be sealed with a dentin bonding agent immediately after tooth preparation, described as immediate dentin sealing (IDS). The purpose of IDS is to prevent dentin contamination during temporary restorations, reduce dentin hypersensitivity, and improve bond strength. Self-etch (SE) adhesive can be easily removed during surface treatment before cementation in the IDS technique. Reinforced SE adhesive with an additional layer of flowable composite significantly increases bond strength. Purpose: This study aimed to determine the effects of reinforcing one-bottle SE adhesive with a three-dimensional self-reinforcing monomer and surface conditioning with air abrasion and pumice on the bonding of composite resin to dentin in the IDS technique. Methods: Thirty-six human premolars were selected and randomly divided into three groups. Each group was divided into two sub-groups (n = 6) according to the adhesive system and surface conditioning. All samples were restored with 3 × 3 × 3 mm composite resin before being tested for shear bond strength. The data were analyzed with two-way ANOVA and Sidak’s multiple comparison test (p < 0.05). Results: There were significant differences between groups. Total-etch with pumice showed a higher mean value of shear bond strength than SE with air abrasion. Conclusion: The use of air abrasion in the IDS technique with SE adhesive affects the shear bond strength of dentin. Surface conditioning with air abrasion or pumice with SE adhesive showed the lowest mean values compared with SE adhesive with an additional layer of flowable composite resin.

Kata kunci

Jaringan kolaborasi para penulis

16 penulis · 39 tautan kepenulisan bersama · 16 lintas organisasi

Arahkan kursor atau ketuk sebuah nama untuk menyorot rekan penulisnya. Klik dua kali untuk membuka halaman penulis.

  • Universitas Trisakti
  • Thammasat University
  • Universiti Sains Malaysia
  • International Islamic University Malaysia
  • University of Yangon
  • Organisasi berbeda
  • Organisasi sama
  • Afiliasi tidak diketahui
  • Garis lebih tebal = lebih banyak artikel bersama · lingkaran lebih besar = lebih banyak artikel
Tampilkan sebagai tabel
Rekan penulisOrganisasiArtikel bersama
Tansza Setiana PutriUniversitas Trisakti2
Deviyanti PratiwiUniversitas Trisakti1
Dewi Liliany MargarettaUniversitas Trisakti1
Khairul Anuar ShariffUniversiti Sains Malaysia1
EllineUniversitas Trisakti1
Anastasia Elsa PrahastiUniversitas Trisakti1
Winny MoniagaUniversitas Trisakti1
Syuwari Azhar AzmanInternational Islamic University Malaysia1
EddyUniversitas Trisakti1
Rafhaela Johanna HalimUniversitas Trisakti1
Thet Thet SweUniversity of Yangon1

Afiliasi berasal dari OpenAlex; metadata OAI-PMH jurnal tidak memuatnya. Penulis tanpa ID OpenAlex dicocokkan berdasarkan nama, sehingga dua orang bisa tergabung atau satu orang bisa terpisah.

Sumber metadata: OAI-PMH (metadata jurnal) https://e-journal.unair.ac.id/MKG/oai, pertama di-harvest 8 Nov 2026, terakhir terlihat 8 Nov 2026.
Metadata asli (oai_dc)
<oai_dc:dc xmlns="http://www.openarchives.org/OAI/2.0/" xmlns:dc="http://purl.org/dc/elements/1.1/" xmlns:oai_dc="http://www.openarchives.org/OAI/2.0/oai_dc/" xmlns:xsi="http://www.w3.org/2001/XMLSchema-instance" xsi:schemaLocation="http://www.openarchives.org/OAI/2.0/oai_dc/  http://www.openarchives.org/OAI/2.0/oai_dc.xsd">
	<dc:title xml:lang="en-US">Reinforcing three-dimensional self-reinforcing self-etch adhesive and surface conditioning in immediate dentin sealing of composite resin–dentin</dc:title>
	<dc:creator>Andriani, Poppy </dc:creator>
	<dc:creator>Prijanti Dwisaptarini, Ade</dc:creator>
	<dc:creator>Fibryanto, Eko</dc:creator>
	<dc:creator>Tjandrawinata, Rosalina</dc:creator>
	<dc:creator>Suebnukarn, Siriwan</dc:creator>
	<dc:subject xml:lang="en-US">Dentin</dc:subject>
	<dc:subject xml:lang="en-US">dentin bonding agent</dc:subject>
	<dc:subject xml:lang="en-US">self-etching adhesive</dc:subject>
	<dc:subject xml:lang="en-US">shear bond strength</dc:subject>
	<dc:subject xml:lang="en-US">surface conditioning</dc:subject>
	<dc:description xml:lang="en-US">


Background: Exposed dentin must be sealed with a dentin bonding agent immediately after tooth preparation, described as immediate dentin sealing (IDS). The purpose of IDS is to prevent dentin contamination during temporary restorations, reduce dentin hypersensitivity, and improve bond strength. Self-etch (SE) adhesive can be easily removed during surface treatment before cementation in the IDS technique. Reinforced SE adhesive with an additional layer of flowable composite significantly increases bond strength. Purpose: This study aimed to determine the effects of reinforcing one-bottle SE adhesive with a three-dimensional self-reinforcing monomer and surface conditioning with air abrasion and pumice on the bonding of composite resin to dentin in the IDS technique. Methods: Thirty-six human premolars were selected and randomly divided into three groups. Each group was divided into two sub-groups (n = 6) according to the adhesive system and surface conditioning. All samples were restored with 3 × 3 × 3 mm composite resin before being tested for shear bond strength. The data were analyzed with two-way ANOVA and Sidak’s multiple comparison test (p &amp;lt; 0.05). Results: There were significant differences between groups. Total-etch with pumice showed a higher mean value of shear bond strength than SE with air abrasion. Conclusion: The use of air abrasion in the IDS technique with SE adhesive affects the shear bond strength of dentin. Surface conditioning with air abrasion or pumice with SE adhesive showed the lowest mean values compared with SE adhesive with an additional layer of flowable composite resin.


</dc:description>
	<dc:publisher xml:lang="en-US">Faculty of Dental Medicine, Universitas Airlangga https://fkg.unair.ac.id/en</dc:publisher>
	<dc:date>2026-04-30</dc:date>
	<dc:type>info:eu-repo/semantics/article</dc:type>
	<dc:type>info:eu-repo/semantics/publishedVersion</dc:type>
	<dc:format>text/xml</dc:format>
	<dc:format>application/pdf</dc:format>
	<dc:identifier>https://e-journal.unair.ac.id/MKG/article/view/60379</dc:identifier>
	<dc:identifier>10.20473/j.djmkg.v59.i2.p141-147</dc:identifier>
	<dc:source xml:lang="en-US">Dental Journal (Majalah Kedokteran Gigi); Vol. 59 No. 2 (2026): June; 141-147</dc:source>
	<dc:source>2442-9740</dc:source>
	<dc:source>1978-3728</dc:source>
	<dc:language>eng</dc:language>
	<dc:relation>https://e-journal.unair.ac.id/MKG/article/view/60379/37670</dc:relation>
	<dc:relation>https://e-journal.unair.ac.id/MKG/article/view/60379/37479</dc:relation>
	<dc:rights xml:lang="en-US">Copyright (c) 2026 Dental Journal (Majalah Kedokteran Gigi)</dc:rights>
	<dc:rights xml:lang="en-US">https://creativecommons.org/licenses/by-sa/4.0</dc:rights>
</oai_dc:dc>