Melola Discovery

← Melola Discovery

Jurnal SINTA 1

Analysis of Groundwater Advance Decline in Surakarta City

Forum Geografi · Vol. 12 No. 2 (2014)

DOI
10.23917/forgeo.v12i2.470
ISSN
2460-3945, 0852-0682
Terbit
2014-12-20
Penerbit
Universitas Muhammadiyah Surakarta
Bahasa
en

Abstrak

This research was intended to know the cause of a drawdown of artesian groundwater surface and analyze on exploiting its groundwater in Surakarta. The total amount of groundwater exploitation in Surakarta will be 69,206.4 m3 if it is compared the groundwater runoff capacity of unconfined aquifer as with 8,860.9 m3 a day and confined aquifer as 42,447.3 m3 a day. Thus, the total amount of groundwater runoff in Surakarta is 51,308.2 m3 a day. Groundwater exploitation has exceeded the capacity of groundwater runoff as 17,898.2 m3, so the reservoir of groundwater is going to reduce continually. Groundwater exploitation in the loation of the researh has caused a piezometric drawdown. In 1990, its piezometric was negative, it means that the position of the piezometric was under the surface of land, while in 1990 artesian well indicated that its piezometric was almost nearly positive. Thus, the piezometric drawdown average 9.4 m3. In the center of the ity, it happened the cone of depression at piezometric contour in 1990, so a piezometric drawdown that resulted from groundwater exploitation exceeding the runoff of groundwater was proved. As a result of groundwater exploitation excessively, it resulted in the inequilibrium of groundwater. This depession has been extending continually as a result of adding wells, so it result in a groundwater drawdown permanently, as happened in the location of the research.

Jaringan kolaborasi para penulis

8 penulis · 22 tautan kepenulisan bersama

Arahkan kursor atau ketuk sebuah nama untuk menyorot rekan penulisnya. Klik dua kali untuk membuka halaman penulis.

  • Muhammadiyah University of Surakarta
  • Afiliasi tidak diketahui
  • Organisasi berbeda
  • Organisasi sama
  • Afiliasi tidak diketahui
  • Garis lebih tebal = lebih banyak artikel bersama · lingkaran lebih besar = lebih banyak artikel
Tampilkan sebagai tabel
Rekan penulisOrganisasiArtikel bersama
Arif JauhariAfiliasi tidak diketahui1
Priyono PriyonoMuhammadiyah University of Surakarta1
‪Kuswaji Dwi PriyonoMuhammadiyah University of Surakarta1
Yuli PriyanaMuhammadiyah University of Surakarta1
Choirul AminMuhammadiyah University of Surakarta1
Alif Noor AnnaMuhammadiyah University of Surakarta1
S SuharjoMuhammadiyah University of Surakarta1

Afiliasi berasal dari OpenAlex; metadata OAI-PMH jurnal tidak memuatnya. Penulis tanpa ID OpenAlex dicocokkan berdasarkan nama, sehingga dua orang bisa tergabung atau satu orang bisa terpisah.

Sumber metadata: OAI-PMH (metadata jurnal) http://journals.ums.ac.id/index.php/fg/oai, pertama di-harvest 8 Nov 2026, terakhir terlihat 16 Nov 2026.
Metadata asli (oai_dc)
<oai_dc:dc xmlns="http://www.openarchives.org/OAI/2.0/" xmlns:dc="http://purl.org/dc/elements/1.1/" xmlns:oai_dc="http://www.openarchives.org/OAI/2.0/oai_dc/" xmlns:xsi="http://www.w3.org/2001/XMLSchema-instance" xsi:schemaLocation="http://www.openarchives.org/OAI/2.0/oai_dc/  http://www.openarchives.org/OAI/2.0/oai_dc.xsd">
	<dc:title xml:lang="en-US">Analysis of Groundwater Advance Decline in Surakarta City</dc:title>
	<dc:creator>Cholil, Munawar</dc:creator>
	<dc:description xml:lang="en-US">This research was intended to know the cause of a drawdown of artesian groundwater surface and analyze on exploiting its groundwater in Surakarta. The total amount of groundwater exploitation in Surakarta will be 69,206.4 m3  if it is compared the groundwater runoff capacity of unconfined aquifer as with 8,860.9 m3 a day and confined aquifer as 42,447.3 m3 a day. Thus, the total amount of groundwater runoff in Surakarta is 51,308.2 m3 a day. Groundwater exploitation has exceeded the capacity of groundwater runoff as 17,898.2 m3, so the reservoir of groundwater is going to reduce continually. Groundwater exploitation in the loation of the researh has caused a piezometric drawdown. In 1990, its piezometric was negative, it means that the position of the piezometric was under the surface of land, while in 1990  artesian well indicated that its piezometric was almost nearly positive. Thus, the piezometric drawdown average 9.4 m3. In the center of the ity, it happened the cone of depression at piezometric contour in 1990, so a piezometric drawdown that resulted from groundwater exploitation exceeding the runoff of groundwater was proved. As a result of groundwater exploitation excessively, it resulted in the inequilibrium of groundwater. This depession has been extending continually as a result of adding wells, so it result in a groundwater drawdown permanently, as happened in the location of the research.</dc:description>
	<dc:publisher xml:lang="en-US">Universitas Muhammadiyah Surakarta</dc:publisher>
	<dc:date>2014-12-20</dc:date>
	<dc:type>info:eu-repo/semantics/article</dc:type>
	<dc:type>info:eu-repo/semantics/publishedVersion</dc:type>
	<dc:type xml:lang="en-US"></dc:type>
	<dc:identifier>https://journals.ums.ac.id/index.php/fg/article/view/470</dc:identifier>
	<dc:identifier>10.23917/forgeo.v12i2.470</dc:identifier>
	<dc:source xml:lang="en-US">Forum Geografi; Vol 12, No 2 (1998)</dc:source>
	<dc:source>2460-3945</dc:source>
	<dc:source>0852-0682</dc:source>
	<dc:language>en</dc:language>
	<dc:rights xml:lang="en-US">Copyright (c) 2015 Forum Geografi</dc:rights>
</oai_dc:dc>