Melola Discovery

← Melola Discovery

Akses terbuka Jurnal SINTA 1

The Effects of Green Open Spaces on Microclimate and Thermal Comfort in Three Integrated Campus in Yogyakarta, Indonesia

Geoplanning: Journal of Geomatics and Planning · Vol. 10 No. 1 (2023) · hlm. 37–44

DOI
10.14710/geoplanning.10.1.37-44
ISSN
2355-6544
Terbit
2023-10-31
Penerbit
Department of Urban and Regional Planning, Diponegoro University
Bahasa
eng
Lisensi
creativecommons.org/licenses/by-nc-sa/4.0

Abstrak

This study aims to assess the effect of green open space (GOS) on the microclimate and thermal comfort in three integrated campuses namely Universitas Gadjah Mada (UGM), Universitas Muhammadiyah Yogyakarta (UMY), and Universitas Pembangunan Nasional (UPN) Veteran. In order to achieve the research objective, three main steps were conducted. First, we mapped the GOS area and density of the three integrated campuses using a high-resolution satellite imagery. Second, three microclimate parameters such as air temperature, relative humidity, and wind speed were measured to each detected green spaces in the morning (08:00 am), at noon (01:00 pm), and afternoon (5:00 pm). Subsequently, the results of microclimate measurements were used to calculate the level of thermal comfort using Thermal Humidity Index (THI) method. Third, we carried out statistical analysis to investigate the correlation between the distribution and the density of GOS and the microclimate conditions. The results showed that a negative (-) correlation occurred between the pattern and density of GOS with temperature and wind speed indicating that clustered GOS significantly reduces the air temperature as well as the wind speed. On the contrary, the relative humidity has been increased. UPN campus has the highest temperature and wind speed and the lowest humidity among other campuses. According to the results of THI, a 100% of the UPN areas are uncomfortable, while at UGM and UMY 42,08% and 11,28% of their area are uncomfortable, respectively. This study found that the existence of GOS has an effect on microclimate depending on pattern and density.

Kata kunci

Jaringan kolaborasi para penulis

16 penulis · 47 tautan kepenulisan bersama · 7 lintas organisasi

Arahkan kursor atau ketuk sebuah nama untuk menyorot rekan penulisnya. Klik dua kali untuk membuka halaman penulis.

  • Universitas Gadjah Mada
  • Ministry of Environment and Forestry, Republic of Indonesia
  • Universitas Papua
  • Afiliasi tidak diketahui
  • Organisasi berbeda
  • Organisasi sama
  • Afiliasi tidak diketahui
  • Garis lebih tebal = lebih banyak artikel bersama · lingkaran lebih besar = lebih banyak artikel
Tampilkan sebagai tabel
Rekan penulisOrganisasiArtikel bersama
Ahmad MaryudiUniversitas Gadjah Mada1
M M MeilaniUniversitas Gadjah Mada1
Wahyu AndayaniUniversitas Gadjah Mada1
Fitria Dewi SusantiUniversitas Gadjah Mada1
Rodd MyersAfiliasi tidak diketahui1
Satyawan PudyatmokoUniversitas Gadjah Mada1
Arni SyawalUniversitas Gadjah Mada1
ELIESER VIKTOR SIRAMIUniversitas Papua1
Esti Gesang SetyadiAfiliasi tidak diketahui1
Pratita PuradyatmikaAfiliasi tidak diketahui1
Rendy Enggar SuwandiUniversitas Gadjah Mada1
Muhammad Ali ImronUniversitas Gadjah Mada1
Asep N KurniaAfiliasi tidak diketahui1

Afiliasi berasal dari OpenAlex; metadata OAI-PMH jurnal tidak memuatnya. Penulis tanpa ID OpenAlex dicocokkan berdasarkan nama, sehingga dua orang bisa tergabung atau satu orang bisa terpisah.

Sumber metadata: OAI-PMH (metadata jurnal) http://ejournal.undip.ac.id/index.php/geoplanning/oai, pertama di-harvest 8 Nov 2026, terakhir terlihat 8 Nov 2026.
Metadata asli (oai_dc)
<oai_dc:dc xmlns="http://www.openarchives.org/OAI/2.0/" xmlns:dc="http://purl.org/dc/elements/1.1/" xmlns:oai_dc="http://www.openarchives.org/OAI/2.0/oai_dc/" xmlns:xsi="http://www.w3.org/2001/XMLSchema-instance" xsi:schemaLocation="http://www.openarchives.org/OAI/2.0/oai_dc/  http://www.openarchives.org/OAI/2.0/oai_dc.xsd">
	<dc:title xml:lang="en-US">The Effects of Green Open Spaces on Microclimate and Thermal Comfort in Three Integrated Campus in Yogyakarta, Indonesia</dc:title>
	<dc:creator>Ambarwati, Nurwidya</dc:creator>
	<dc:creator>Faida, Lies Rahayu Wijayanti</dc:creator>
	<dc:creator>Marhaento, Hero</dc:creator>
	<dc:subject xml:lang="en-US">Green open space, microclimates, thermal comfort, university campus, yogyakarta</dc:subject>
	<dc:description xml:lang="en-US">This study aims to assess the effect of green open space (GOS) on the microclimate and thermal comfort in three integrated campuses namely Universitas Gadjah Mada (UGM), Universitas Muhammadiyah Yogyakarta (UMY), and Universitas Pembangunan Nasional (UPN) Veteran. In order to achieve the research objective, three main steps were conducted. First, we mapped the GOS area and density of the three integrated campuses using a high-resolution satellite imagery. Second, three microclimate parameters such as air temperature, relative humidity, and wind speed were measured to each detected green spaces in the morning (08:00 am), at noon (01:00 pm), and afternoon (5:00 pm). Subsequently, the results of microclimate measurements were used to calculate the level of thermal comfort using Thermal Humidity Index (THI) method. Third, we carried out statistical analysis to investigate the correlation between the distribution and the density of GOS and the microclimate conditions. The results showed that a negative (-) correlation occurred between the pattern and density of GOS with temperature and wind speed indicating that clustered GOS significantly reduces the air temperature as well as the wind speed. On the contrary, the relative humidity has been increased. UPN campus has the highest temperature and wind speed and the lowest humidity among other campuses. According to the results of THI, a 100% of the UPN areas are uncomfortable, while at UGM and UMY 42,08% and 11,28% of their area are uncomfortable, respectively. This study found that the existence of GOS has an effect on microclimate depending on pattern and density.</dc:description>
	<dc:publisher xml:lang="en-US">Department of Urban and Regional Planning, Diponegoro University</dc:publisher>
	<dc:date>2023-10-31</dc:date>
	<dc:type>info:eu-repo/semantics/article</dc:type>
	<dc:type>info:eu-repo/semantics/publishedVersion</dc:type>
	<dc:type xml:lang="en-US"></dc:type>
	<dc:format>application/pdf</dc:format>
	<dc:identifier>https://ejournal.undip.ac.id/index.php/geoplanning/article/view/49809</dc:identifier>
	<dc:identifier>10.14710/geoplanning.10.1.37-44</dc:identifier>
	<dc:source xml:lang="en-US">Geoplanning: Journal of Geomatics and Planning; Vol 10, No 1 (2023); 37-44</dc:source>
	<dc:source>2355-6544</dc:source>
	<dc:language>eng</dc:language>
	<dc:relation>https://ejournal.undip.ac.id/index.php/geoplanning/article/view/49809/pdf</dc:relation>
	<dc:rights xml:lang="en-US">Copyright (c) 2023 GJGP-UNDIP</dc:rights>
	<dc:rights xml:lang="en-US">http://creativecommons.org/licenses/by-nc-sa/4.0</dc:rights>
</oai_dc:dc>