Trapping Technique for Successful Retrieval of a Ruptured Balloon Catheter Entrapped in Coronary Artery: A Case Report

Heart Science Journal · Vol. 1 No. 2 (2020) · hlm. 43–46

DOI
10.21776/ub.hsj.2020.001.02.8
ISSN
2721-9984, 2721-9976
Terbit
2020-07-22
Penerbit
Universitas Brawijaya
Bahasa
en

Abstrak

Introduction: Device entrapment during PCI is an uncommon complication with incidence of less than 1%. Percutaneous retrieval should be favored as the treatment of choice for this condition.Case Illustration: A 61-year-old patient came for an elective percutaneous coronary intervention (PCI) procedure. She suffered from chest pain while doing moderate activities for 1 month. Angiography showed a diffuse lesion with maximum stenosis 90% in the proximal LAD, stenosis 75% in the proximal of Left Circumflex Artery (LCx), and diffuse lesions in the proximal and mid of the Right Coronary Artery (RCA). We decided to perform PCI in the LAD. A transfemoral coronary intervention was performed using a Judkins Left 3.5 (7F) guiding catheter to engage the LAD. A Guidewire ( Run-through NS Floppy) was advanced to the distal LAD. Balloon angioplasty was performed with a 2.75 x 15 mm Fluydo balloon in the proximal LAD at 16 bars, but the balloon was entrapped and while withdrawing the balloon, it accidentally ruptured in the LAD artery with the remaining segment inside the guiding catheter. A second Run-through NS Floppy Guidewire was inserted across the ruptured balloon and a 2.5 x 20 mm Fluydo Balloon was passed on the second wire and was inflated at 16 atm pressure, inside the guiding catheter, trapping the ruptured balloon. The ruptured balloon was successfully removed, by withdrawing the whole system, including the guiding catheter and the wire. Finally, we re-engaged the LAD with the same guiding catheter, passed the wire, and post dilated the stent on the LAD to achieve a good result.Conclusion: Percutaneous retrieval using trapping technique could represent a safe and effective technique for ruptured and entrapment of a balloon-catheter in a coronary artery.

Kata kunci

Jaringan kolaborasi para penulis

40 penulis · 306 tautan kepenulisan bersama · menampilkan 40 yang paling banyak terhubung

Arahkan kursor atau ketuk sebuah nama untuk menyorot rekan penulisnya. Klik dua kali untuk membuka halaman penulis.

  • University of Brawijaya
  • Afiliasi tidak diketahui
  • Organisasi berbeda
  • Organisasi sama
  • Afiliasi tidak diketahui
  • Garis lebih tebal = lebih banyak artikel bersama · lingkaran lebih besar = lebih banyak artikel
Tampilkan sebagai tabel
Rekan penulisOrganisasiArtikel bersama
Setyasih AnjarwaniUniversity of Brawijaya45
Anna Fuji RahimahUniversity of Brawijaya43
Cholid Tri TjahjonoUniversity of Brawijaya41
Ardian RizalUniversity of Brawijaya38
Novi KurnianingsihUniversity of Brawijaya33
Djanggan SargowoUniversity of Brawijaya23
Sasmojo WiditoUniversity of Brawijaya23
Yoga WaranugrahaUniversity of Brawijaya12
Valerinna YogibuanaAfiliasi tidak diketahui10
Wella KarolinaUniversity of Brawijaya9
Muhammad Rizki FadlanUniversity of Brawijaya9
Hayla Iqda MillisaniUniversity of Brawijaya7
Seprian WidasmaraUniversity of Brawijaya7
Tri AstiawatiUniversity of Brawijaya6
Ayu Asri Devi AdityawatiUniversity of Brawijaya6
Valerinna Yogibuana Swastika PutriUniversity of Brawijaya6
Adhika Prastya WikanandaUniversity of Brawijaya5
Tria Yudha NugrahaUniversity of Brawijaya5
Dadang HendrawanUniversity of Brawijaya5
Fandy HazzyUniversity of Brawijaya5
Dea Arie KurniawanUniversity of Brawijaya5
Anna Fuji RahimahAfiliasi tidak diketahui5
Ratna PancasariUniversity of Brawijaya5
Lutfi Hafiz ZunardiUniversity of Brawijaya5
Fahmy RusnantaUniversity of Brawijaya4
Oktafin Srywati PamunaUniversity of Brawijaya4
Shalahuddin Suryo BaskoroUniversity of Brawijaya4
Nikhen NoverikeUniversity of Brawijaya4
Teguh AryanugrahaUniversity of Brawijaya4
Lukitasari Ayu Galuh ArdhiUniversity of Brawijaya3
Yuri AfifahUniversity of Brawijaya3
Akhmad Isna NurudinullohUniversity of Brawijaya3
Muhammad Saifur RohmanAfiliasi tidak diketahui3
Saskia Dyah HandariUniversity of Brawijaya3
Dion SetiawanUniversity of Brawijaya3

Afiliasi berasal dari OpenAlex; metadata OAI-PMH jurnal tidak memuatnya. Penulis tanpa ID OpenAlex dicocokkan berdasarkan nama, sehingga dua orang bisa tergabung atau satu orang bisa terpisah.

Sumber metadata: OAI-PMH (metadata jurnal) https://heartscience.ub.ac.id/index.php/heartscience/oai, pertama di-harvest 8 Nov 2026, terakhir terlihat 8 Nov 2026.
Metadata asli (oai_dc)
<oai_dc:dc xmlns="http://www.openarchives.org/OAI/2.0/" xmlns:dc="http://purl.org/dc/elements/1.1/" xmlns:oai_dc="http://www.openarchives.org/OAI/2.0/oai_dc/" xmlns:xsi="http://www.w3.org/2001/XMLSchema-instance" xsi:schemaLocation="http://www.openarchives.org/OAI/2.0/oai_dc/  http://www.openarchives.org/OAI/2.0/oai_dc.xsd">
	<dc:title xml:lang="en">Trapping Technique for Successful Retrieval of a Ruptured Balloon Catheter Entrapped in Coronary Artery : A Case Report</dc:title>
	<dc:creator xml:lang="en">Kamila, Putri Annisa</dc:creator>
	<dc:creator xml:lang="en">Satrijo, Budi</dc:creator>
	<dc:creator xml:lang="en">Rohman, Mohammad Saifur</dc:creator>
	<dc:creator xml:lang="en">Martini, Heny</dc:creator>
	<dc:creator xml:lang="en">Prasetya, Indra</dc:creator>
	<dc:subject xml:lang="en">balloon assisted technique</dc:subject>
	<dc:subject xml:lang="en">balloon fracture</dc:subject>
	<dc:subject xml:lang="en">coronary balloon retrieval</dc:subject>
	<dc:description xml:lang="en">Introduction: Device entrapment during PCI is an uncommon complication with incidence of less than 1%. Percutaneous retrieval should be favored as the treatment of choice for this condition.Case Illustration: A 61-year-old patient came for an elective percutaneous coronary intervention (PCI) procedure. She suffered from chest pain while doing moderate activities for 1 month. Angiography showed a diffuse lesion with maximum stenosis 90% in the proximal LAD, stenosis 75% in the proximal of Left Circumflex Artery (LCx), and diffuse lesions in the proximal and mid of the Right Coronary Artery (RCA). We decided to perform PCI in the LAD. A transfemoral coronary intervention was performed using a Judkins Left 3.5 (7F) guiding catheter to engage the LAD. A Guidewire ( Run-through NS Floppy) was advanced to the distal LAD. Balloon angioplasty was performed with a 2.75 x 15 mm Fluydo balloon in the proximal LAD at 16 bars, but the balloon was entrapped and while withdrawing the balloon, it accidentally ruptured in the LAD artery with the remaining segment inside the guiding catheter. A second Run-through NS Floppy Guidewire was inserted across the ruptured balloon and a 2.5 x 20 mm Fluydo Balloon was passed on the second wire and was inflated at 16 atm pressure, inside the guiding catheter, trapping the ruptured balloon. The ruptured balloon was successfully removed, by withdrawing the whole system, including the guiding catheter and the wire. Finally, we re-engaged the LAD with the same guiding catheter, passed the wire, and post dilated the stent on the LAD to achieve a good result.Conclusion: Percutaneous retrieval using trapping technique could represent a safe and effective technique for ruptured and entrapment of a balloon-catheter in a coronary artery.</dc:description>
	<dc:publisher xml:lang="en">Universitas Brawijaya</dc:publisher>
	<dc:date>2020-07-22</dc:date>
	<dc:type>info:eu-repo/semantics/article</dc:type>
	<dc:type>info:eu-repo/semantics/publishedVersion</dc:type>
	<dc:format>application/pdf</dc:format>
	<dc:identifier>https://heartscience.ub.ac.id/index.php/heartscience/article/view/55</dc:identifier>
	<dc:identifier>10.21776/ub.hsj.2020.001.02.8</dc:identifier>
	<dc:source xml:lang="en">Heart Science Journal; Vol. 1 No. 2 (2020): The Assessment of Diagnostic and Treatment Modality in Heart Failure; 43-46</dc:source>
	<dc:source>2721-9984</dc:source>
	<dc:source>2721-9976</dc:source>
	<dc:source>10.21776/ub.hsj.2020.001.02</dc:source>
	<dc:language>en</dc:language>
	<dc:relation>https://heartscience.ub.ac.id/index.php/heartscience/article/view/55/329</dc:relation>
	<dc:rights xml:lang="en">Copyright (c) 2020 Heart Science Journal</dc:rights>
</oai_dc:dc>