Melola Discovery

← Melola Discovery

Akses terbuka Jurnal SINTA 1

Low-tech, high-value: Electrocardiographic markers of left ventricular dysfunction in non-ischemic cardiomyopathy

Heart Science Journal · Vol. 6 No. 4 (2025)

DOI
10.21776/ub.hsj.2025.006.04.14
ISSN
2721-9984, 2721-9976
Terbit
2025-10-31
Penerbit
Universitas Brawijaya
Bahasa
en
Lisensi
creativecommons.org/licenses/by/4.0

Abstrak

Background: Electrocardiography (ECG) is a widely accessible, cost-effective diagnostic tool, particularly valuable in resource-limited settings where echocardiography is unavailable. Identifying ECG parameters that reflect left ventricular (LV) systolic dysfunction could enable earlier detection and intervention in patients with non-ischemic cardiomyopathy (NICM). Objectives: To evaluate the correlation between ECG parameters—QTc duration, QRS duration, morphology, voltage, and axis—and left ventricular ejection fraction (LVEF) in NICM patients with reduced ejection fraction (REF), and to assess their potential as surrogate markers of LV systolic function. Methods: A cross-sectional study was conducted on 140 NICM patients (LVEF ≤40%) confirmed by echocardiography and angiography. Clinical, biochemical, and ECG data were collected. Pearson’s correlation and ANOVA were used to assess associations between ECG variables, mitral regurgitation (MR) severity, hemoglobin levels, and LVEF. Results: QTc duration showed a significant inverse correlation with LVEF (r = –0.428, p = 0.001). Hemoglobin levels were positively correlated with LVEF (r = 0.175, p = 0.039). The presence of mitral regurgitation was associated with lower LVEF (p = 0.029), with a trend toward further decline as severity increased. Conclusions: Prolonged QTc was strongly associated with reduced LVEF in patients with non-ischemic cardiomyopathy. As ECG is inexpensive and widely available, QTc may provide a simple surrogate marker to aid in identifying LV dysfunction, especially in resource-limited settings. Larger prospective studies with outcome data are needed to validate its prognostic role.

Kata kunci

Jaringan kolaborasi para penulis

6 penulis · 15 tautan kepenulisan bersama

Arahkan kursor atau ketuk sebuah nama untuk menyorot rekan penulisnya. Klik dua kali untuk membuka halaman penulis.

  • Banaras Hindu University
  • Organisasi berbeda
  • Organisasi sama
  • Afiliasi tidak diketahui
  • Garis lebih tebal = lebih banyak artikel bersama · lingkaran lebih besar = lebih banyak artikel
Tampilkan sebagai tabel
Rekan penulisOrganisasiArtikel bersama

Afiliasi berasal dari OpenAlex; metadata OAI-PMH jurnal tidak memuatnya. Penulis tanpa ID OpenAlex dicocokkan berdasarkan nama, sehingga dua orang bisa tergabung atau satu orang bisa terpisah.

Sumber metadata: OAI-PMH (metadata jurnal) https://heartscience.ub.ac.id/index.php/heartscience/oai, pertama di-harvest 8 Nov 2026, terakhir terlihat 22 Nov 2026.
Metadata asli (oai_dc)
<oai_dc:dc xmlns="http://www.openarchives.org/OAI/2.0/" xmlns:dc="http://purl.org/dc/elements/1.1/" xmlns:oai_dc="http://www.openarchives.org/OAI/2.0/oai_dc/" xmlns:xsi="http://www.w3.org/2001/XMLSchema-instance" xsi:schemaLocation="http://www.openarchives.org/OAI/2.0/oai_dc/  http://www.openarchives.org/OAI/2.0/oai_dc.xsd">
	<dc:title xml:lang="en">Low-tech, high-value: Electrocardiographic markers of left ventricular dysfunction in non-ischemic cardiomyopathy</dc:title>
	<dc:creator xml:lang="en">Ghosh, Soumik</dc:creator>
	<dc:creator xml:lang="en">Tandon, Arjun</dc:creator>
	<dc:creator xml:lang="en">Kulshreshtha, Srashti</dc:creator>
	<dc:creator xml:lang="en">Kumar A, Lava</dc:creator>
	<dc:creator xml:lang="en">Amit, Kumar</dc:creator>
	<dc:creator xml:lang="en">Agrawal, Vikas</dc:creator>
	<dc:subject xml:lang="en">Electrocardiography (ECG)</dc:subject>
	<dc:subject xml:lang="en">Heart Failure</dc:subject>
	<dc:subject xml:lang="en">left ventricular dysfunction</dc:subject>
	<dc:subject xml:lang="en">non ischemic cardiomyopathy </dc:subject>
	<dc:subject xml:lang="en">QRS duration </dc:subject>
	<dc:description xml:lang="en">Background: Electrocardiography (ECG) is a widely accessible, cost-effective diagnostic tool, particularly valuable in resource-limited settings where echocardiography is unavailable. Identifying ECG parameters that reflect left ventricular (LV) systolic dysfunction could enable earlier detection and intervention in patients with non-ischemic cardiomyopathy (NICM).
Objectives: To evaluate the correlation between ECG parameters—QTc duration, QRS duration, morphology, voltage, and axis—and left ventricular ejection fraction (LVEF) in NICM patients with reduced ejection fraction (REF), and to assess their potential as surrogate markers of LV systolic function.
Methods: A cross-sectional study was conducted on 140 NICM patients (LVEF ≤40%) confirmed by echocardiography and angiography. Clinical, biochemical, and ECG data were collected. Pearson’s correlation and ANOVA were used to assess associations between ECG variables, mitral regurgitation (MR) severity, hemoglobin levels, and LVEF.
Results: QTc duration showed a significant inverse correlation with LVEF (r = –0.428, p = 0.001). Hemoglobin levels were positively correlated with LVEF (r = 0.175, p = 0.039). The presence of mitral regurgitation was associated with lower LVEF (p = 0.029), with a trend toward further decline as severity increased.
Conclusions: Prolonged QTc was strongly associated with reduced LVEF in patients with non-ischemic cardiomyopathy. As ECG is inexpensive and widely available, QTc may provide a simple surrogate marker to aid in identifying LV dysfunction, especially in resource-limited settings. Larger prospective studies with outcome data are needed to validate its prognostic role. </dc:description>
	<dc:publisher xml:lang="en">Universitas Brawijaya</dc:publisher>
	<dc:date>2025-10-31</dc:date>
	<dc:type>info:eu-repo/semantics/article</dc:type>
	<dc:type>info:eu-repo/semantics/publishedVersion</dc:type>
	<dc:format>application/pdf</dc:format>
	<dc:identifier>https://heartscience.ub.ac.id/index.php/heartscience/article/view/20433</dc:identifier>
	<dc:identifier>10.21776/ub.hsj.2025.006.04.14</dc:identifier>
	<dc:source xml:lang="en">Heart Science Journal; Vol. 6 No. 4 (2025): The Pursuit of Precision: Navigating Risks, Refining Diagnosis, and Securing Long-Term Vascular Outcomes in Contemporary Cardiovascular Practice</dc:source>
	<dc:source>2721-9984</dc:source>
	<dc:source>2721-9976</dc:source>
	<dc:source>10.21776/ub.hsj.2025.006.04</dc:source>
	<dc:language>en</dc:language>
	<dc:relation>https://heartscience.ub.ac.id/index.php/heartscience/article/view/20433/544</dc:relation>
	<dc:rights xml:lang="en">Copyright (c) 2025 Soumik Ghosh, Arjun Tandon, Srashti Kulshreshtha, Lava Kumar A, Kumar Amit, Vikas Agrawal</dc:rights>
	<dc:rights xml:lang="en">http://creativecommons.org/licenses/by/4.0</dc:rights>
</oai_dc:dc>