Akses terbuka
Jurnal
SINTA 1
Local anesthetic systemic toxicity (LAST) during pacemaker implantation through persistent left superior vena cava (PLSVC)
Heart Science Journal · Vol. 6 No. 4 (2025)
ISSN 2721-9984, 2721-9976
Terbit 2025-10-31
Penerbit Universitas Brawijaya
Bahasa en
Abstrak
BACKGROUND: Local anesthesia is considered safe and commonly used in the pacemaker implantation procedure. However, it carries a risk of local anesthetic systemic toxicity (LAST). Although rare, LAST occurrence can be fatal. CASE PRESENTATIONS: We reported a case of a 69-year-old woman with fatigue and dizziness. The patient's ECG indicates atrial fibrillation with total AV block. Pacemaker implantation was performed under local anesthesia. Within minutes of lidocaine injection, the patient developed a seizure followed by cardiac arrest. Immediate administration of intravenous midazolam and cardiopulmonary resuscitation was done, resulting in the patient's stability. A permanent pacemaker was successfully implanted using a modified hand-shaped stylet to accommodate the presence of a persistent left superior vena cava (PLSVC). Brain computed tomography scan showed only mild brain atrophy. No clinical symptoms were documented during the outpatient visit after discharge. CONCLUSIONS: Local anesthetic systemic toxicity during pacemaker implantation is a rare but potentially catastrophic. Prompt recognition of its signs and appropriate management are crucial. In this case, a persistent left superior vena cava posed additional challenges to the pacemaker implantation.
Jaringan kolaborasi para penulis
11 penulis ·
35 tautan kepenulisan bersama
· 7 lintas organisasi
Arahkan kursor atau ketuk sebuah nama untuk menyorot rekan penulisnya. Klik dua kali untuk membuka halaman penulis.
University of Indonesia Taipei Veterans General Hospital
Organisasi berbeda
Organisasi sama
Afiliasi tidak diketahui
Garis lebih tebal = lebih banyak artikel bersama · lingkaran lebih besar = lebih banyak artikel
Tampilkan sebagai tabel
Afiliasi berasal dari OpenAlex; metadata OAI-PMH jurnal tidak memuatnya. Penulis tanpa ID OpenAlex dicocokkan berdasarkan nama, sehingga dua orang bisa tergabung atau satu orang bisa terpisah.
Sumber metadata: OAI-PMH (metadata jurnal) https://heartscience.ub.ac.id/index.php/heartscience/oai, pertama di-harvest 8 Nov 2026, terakhir terlihat 16 Nov 2026.
Metadata asli (oai_dc)
<oai_dc:dc xmlns="http://www.openarchives.org/OAI/2.0/" xmlns:dc="http://purl.org/dc/elements/1.1/" xmlns:oai_dc="http://www.openarchives.org/OAI/2.0/oai_dc/" xmlns:xsi="http://www.w3.org/2001/XMLSchema-instance" xsi:schemaLocation="http://www.openarchives.org/OAI/2.0/oai_dc/ http://www.openarchives.org/OAI/2.0/oai_dc.xsd">
<dc:title xml:lang="en">Local anesthetic systemic toxicity (LAST) during pacemaker implantation through persistent left superior vena cava (PLSVC)</dc:title>
<dc:creator xml:lang="en">Sunu Budhi Raharjo</dc:creator>
<dc:creator xml:lang="en">Gadistya Novitri Adinda</dc:creator>
<dc:creator xml:lang="en">Dony Yugo Hermanto</dc:creator>
<dc:creator xml:lang="en">Indira Aura Balqis</dc:creator>
<dc:creator xml:lang="en">Dicky Armein Hanafy</dc:creator>
<dc:subject xml:lang="en">Local anesthesia systemic toxicity</dc:subject>
<dc:subject xml:lang="en"> lidocaine toxicity</dc:subject>
<dc:subject xml:lang="en">persistent left superior vena cava</dc:subject>
<dc:subject xml:lang="en">venous anomaly</dc:subject>
<dc:subject xml:lang="en">pacemaker implantation</dc:subject>
<dc:description xml:lang="en">BACKGROUND: Local anesthesia is considered safe and commonly used in the pacemaker implantation procedure. However, it carries a risk of local anesthetic systemic toxicity (LAST). Although rare, LAST occurrence can be fatal.
CASE PRESENTATIONS: We reported a case of a 69-year-old woman with fatigue and dizziness. The patient's ECG indicates atrial fibrillation with total AV block. Pacemaker implantation was performed under local anesthesia. Within minutes of lidocaine injection, the patient developed a seizure followed by cardiac arrest. Immediate administration of intravenous midazolam and cardiopulmonary resuscitation was done, resulting in the patient's stability. A permanent pacemaker was successfully implanted using a modified hand-shaped stylet to accommodate the presence of a persistent left superior vena cava (PLSVC). Brain computed tomography scan showed only mild brain atrophy. No clinical symptoms were documented during the outpatient visit after discharge.
CONCLUSIONS: Local anesthetic systemic toxicity during pacemaker implantation is a rare but potentially catastrophic. Prompt recognition of its signs and appropriate management are crucial. In this case, a persistent left superior vena cava posed additional challenges to the pacemaker implantation.</dc:description>
<dc:publisher xml:lang="en">Universitas Brawijaya</dc:publisher>
<dc:date>2025-10-31</dc:date>
<dc:type>info:eu-repo/semantics/article</dc:type>
<dc:type>info:eu-repo/semantics/publishedVersion</dc:type>
<dc:format>application/pdf</dc:format>
<dc:identifier>https://heartscience.ub.ac.id/index.php/heartscience/article/view/20480</dc:identifier>
<dc:identifier>10.21776/ub.hsj.2025.006.04.18</dc:identifier>
<dc:source xml:lang="en">Heart Science Journal; Vol. 6 No. 4 (2025): The Pursuit of Precision: Navigating Risks, Refining Diagnosis, and Securing Long-Term Vascular Outcomes in Contemporary Cardiovascular Practice</dc:source>
<dc:source>2721-9984</dc:source>
<dc:source>2721-9976</dc:source>
<dc:source>10.21776/ub.hsj.2025.006.04</dc:source>
<dc:language>en</dc:language>
<dc:relation>https://heartscience.ub.ac.id/index.php/heartscience/article/view/20480/548</dc:relation>
<dc:rights xml:lang="en">Copyright (c) 2025 Sunu Budhi Raharjo, MD, PhD, Gadistya Novitri Adinda, MD, Dony Yugo Hermanto, MD, Indira Aura Balqis, MD, Dicky Armein Hanafy, MD, PhD</dc:rights>
<dc:rights xml:lang="en">http://creativecommons.org/licenses/by/4.0</dc:rights>
</oai_dc:dc>
Sitasi dan pengindeksan
Jumlah menurut tiap indeks pada 13 Nov 2026; setiap indeks menghitung sitasi dengan cara berbeda.
OpenAlex juga mencatat karya ini di: crossref.
Sitasi artikel ini
APA 7
Raharjo, S. B., Adinda, G. N., Hermanto, D. Y., Balqis, I. A., & Hanafy, D. A. (2025). Local anesthetic systemic toxicity (LAST) during pacemaker implantation through persistent left superior vena cava (PLSVC). Heart Science Journal, 6(4). https://doi.org/10.21776/ub.hsj.2025.006.04.18
Salin
IEEE
S. B. Raharjo, G. N. Adinda, D. Y. Hermanto, I. A. Balqis, and D. A. Hanafy, “Local anesthetic systemic toxicity (LAST) during pacemaker implantation through persistent left superior vena cava (PLSVC),” Heart Science Journal, vol. 6, no. 4, 2025, doi: 10.21776/ub.hsj.2025.006.04.18.
Salin