Melola Discovery

← Melola Discovery

Akses terbuka Jurnal SINTA 1

Stacking ensemble techniques for automated peripheral blood cell classification using Inception v3 features

IAES International Journal of Artificial Intelligence · Vol. 15 No. 3 (2026) · hlm. 2247–2259

DOI
10.11591/ijai.v15.i3.pp2247-2259
ISSN
2252-8938, 2089-4872
Terbit
2026-06-01
Penerbit
Institute of Advanced Engineering and Science
Bahasa
eng
Lisensi
creativecommons.org/licenses/by-sa/4.0

Abstrak

Robust distinction of blood cells is crucial in clinical evaluation. Manual examination is slow and exposed to errors. This work investigates using machine learning (ML) techniques for automated classification of eight categories of peripheral blood cell types from multi-color images. The Inception v3 network was used to extract features, a split of 66%/34% were used to evaluate the model along with 20-fold cross-validation. To reduce computational complexity, principal component analysis (PCA) was used to reduce the 2048-dimensional feature vectors to 100 components. Among all classifiers used, the highest performance without using PCA was achieved using the support vector machine (SVM) with an accuracy equal to 93.4% and an area under the curve (AUC) of 0.996. Using PCA, affected monocytes and immature granulocytes most due to the slight reduction in the accuracy and AUC which became 90.1% and to 0.991 respectively. Results were further enhanced when a stacked ensemble of neural network (NN), logistic regression (LR), and SVM were used, achieving an accuracy of 95.2% and an AUC of 0.998. The obtained findings confirmed the effectiveness of using stacked ensembles in providing a robust, high accuracy framework for automated blood cell classification, while PCA efficiently reduced dimensions with minimal performance loss.

Kata kunci

Jaringan kolaborasi para penulis

6 penulis · 9 tautan kepenulisan bersama

Arahkan kursor atau ketuk sebuah nama untuk menyorot rekan penulisnya. Klik dua kali untuk membuka halaman penulis.

  • Northern Technical University
  • Organisasi berbeda
  • Organisasi sama
  • Afiliasi tidak diketahui
  • Garis lebih tebal = lebih banyak artikel bersama · lingkaran lebih besar = lebih banyak artikel
Tampilkan sebagai tabel
Rekan penulisOrganisasiArtikel bersama
Sinan S. Mohammed SheetNorthern Technical University2
Lubab H. AlbakNorthern Technical University2
Raid Rafi Omar Al-NimaNorthern Technical University2

Afiliasi berasal dari OpenAlex; metadata OAI-PMH jurnal tidak memuatnya. Penulis tanpa ID OpenAlex dicocokkan berdasarkan nama, sehingga dua orang bisa tergabung atau satu orang bisa terpisah.

Sumber metadata: OAI-PMH (metadata jurnal) http://ijai.iaescore.com/index.php/IJAI/oai, pertama di-harvest 8 Nov 2026, terakhir terlihat 22 Nov 2026.
Metadata asli (oai_dc)
<oai_dc:dc xmlns="http://www.openarchives.org/OAI/2.0/" xmlns:dc="http://purl.org/dc/elements/1.1/" xmlns:oai_dc="http://www.openarchives.org/OAI/2.0/oai_dc/" xmlns:xsi="http://www.w3.org/2001/XMLSchema-instance" xsi:schemaLocation="http://www.openarchives.org/OAI/2.0/oai_dc/  http://www.openarchives.org/OAI/2.0/oai_dc.xsd">
	<dc:title xml:lang="en-US">Stacking ensemble techniques for automated peripheral blood cell classification using Inception v3 features</dc:title>
	<dc:creator>Al-Hatab, Marwa Mawfaq Mohamedsheet</dc:creator>
	<dc:creator>Qasim, Maysaloon Abed</dc:creator>
	<dc:creator>Sultan, Nawar A.</dc:creator>
	<dc:subject xml:lang="en-US"></dc:subject>
	<dc:subject xml:lang="en-US">Cross validation; Ensemble learning; Inception v3; Machine learning; Principal component analysis</dc:subject>
	<dc:description xml:lang="en-US">Robust distinction of blood cells is crucial in clinical evaluation. Manual examination is slow and exposed to errors. This work investigates using machine learning (ML) techniques for automated classification of eight categories of peripheral blood cell types from multi-color images. The Inception v3 network was used to extract features, a split of 66%/34% were used to evaluate the model along with 20-fold cross-validation. To reduce computational complexity, principal component analysis (PCA) was used to reduce the 2048-dimensional feature vectors to 100 components. Among all classifiers used, the highest performance without using PCA was achieved using the support vector machine (SVM) with an accuracy equal to 93.4% and an area under the curve (AUC) of 0.996. Using PCA, affected monocytes and immature granulocytes most due to the slight reduction in the accuracy and AUC which became 90.1% and to 0.991 respectively. Results were further enhanced when a stacked ensemble of neural network (NN), logistic regression (LR), and SVM were used, achieving an accuracy of 95.2% and an AUC of 0.998. The obtained findings confirmed the effectiveness of using stacked ensembles in providing a robust, high accuracy framework for automated blood cell classification, while PCA efficiently reduced dimensions with minimal performance loss.</dc:description>
	<dc:publisher xml:lang="en-US">Institute of Advanced Engineering and Science</dc:publisher>
	<dc:contributor xml:lang="en-US"></dc:contributor>
	<dc:date>2026-06-01</dc:date>
	<dc:type>info:eu-repo/semantics/article</dc:type>
	<dc:type>info:eu-repo/semantics/publishedVersion</dc:type>
	<dc:type xml:lang="en-US"></dc:type>
	<dc:format>application/pdf</dc:format>
	<dc:identifier>https://ijai.iaescore.com/index.php/IJAI/article/view/30366</dc:identifier>
	<dc:identifier>10.11591/ijai.v15.i3.pp2247-2259</dc:identifier>
	<dc:source xml:lang="en-US">IAES International Journal of Artificial Intelligence (IJ-AI); Vol 15, No 3: June 2026; 2247-2259</dc:source>
	<dc:source>2252-8938</dc:source>
	<dc:source>2089-4872</dc:source>
	<dc:source>10.11591/ijai.v15.i3</dc:source>
	<dc:language>eng</dc:language>
	<dc:relation>https://ijai.iaescore.com/index.php/IJAI/article/view/30366/15264</dc:relation>
	<dc:rights xml:lang="en-US">Copyright (c) 2026 Marwa Mawfaq Mohamedsheet Al-Hatab, Maysaloon Abed Qasim, Nawar A. Sultan</dc:rights>
	<dc:rights xml:lang="en-US">http://creativecommons.org/licenses/by-sa/4.0</dc:rights>
</oai_dc:dc>