Melola Discovery

← Melola Discovery

Akses terbuka Jurnal SINTA 1

Deep retino-network for automatic quantification of diabetic retinopathy

IAES International Journal of Artificial Intelligence · Vol. 13 No. 3 (2024) · hlm. 3306–3313

DOI
10.11591/ijai.v13.i3.pp3306-3313
ISSN
2252-8938, 2089-4872
Terbit
2024-09-01
Penerbit
Institute of Advanced Engineering and Science
Bahasa
eng
Lisensi
creativecommons.org/licenses/by-sa/4.0

Abstrak

Diabetic retinopathy (DR) is the ocular manifestation of the systemic disease. Since it is the most prevalent cause of blindness in the world, it demands a significant amount of therapeutic attention. As a result, a precise assessment of the DR condition as well as its evolution is very important for treatment. In this work, an automated quantification of diabetic retinopathy state (AQDRS) using fundus images is proposed. The state of DR is classified into 0 (low) to 3 (high) with the help of a deep retino-network (DRN). Before the classification by DRN, an image down-sampling scheme is employed. A DRN consists of convolution layer and max-pooling layers to extract the deep retina features and fully connected layer (FCL) for AQDRS where feed-forward neural network is employed for the classification. The performance of AQDRS by DRN for grading DR is evaluated using methods to evaluate segmentation and indexing techniques in the field of retinal ophthalmology (MESSIDOR) database. Results show that the AQDRS by DRN can able to extract the relevant discriminative information for grading the fundus image. The average accuracy on normal images in MESSIDOR database is 97.9% and it is 95.3% for DR images.

Kata kunci

Jaringan kolaborasi para penulis

3 penulis · 2 tautan kepenulisan bersama

Arahkan kursor atau ketuk sebuah nama untuk menyorot rekan penulisnya. Klik dua kali untuk membuka halaman penulis.

  • Bharathidasan University
  • Afiliasi tidak diketahui
  • Organisasi berbeda
  • Organisasi sama
  • Afiliasi tidak diketahui
  • Garis lebih tebal = lebih banyak artikel bersama · lingkaran lebih besar = lebih banyak artikel
Tampilkan sebagai tabel
Rekan penulisOrganisasiArtikel bersama
Dakshinamoorthy MeenakshiBharathidasan University1

Afiliasi berasal dari OpenAlex; metadata OAI-PMH jurnal tidak memuatnya. Penulis tanpa ID OpenAlex dicocokkan berdasarkan nama, sehingga dua orang bisa tergabung atau satu orang bisa terpisah.

Sumber metadata: OAI-PMH (metadata jurnal) http://ijai.iaescore.com/index.php/IJAI/oai, pertama di-harvest 8 Nov 2026, terakhir terlihat 22 Nov 2026.
Metadata asli (oai_dc)
<oai_dc:dc xmlns="http://www.openarchives.org/OAI/2.0/" xmlns:dc="http://purl.org/dc/elements/1.1/" xmlns:oai_dc="http://www.openarchives.org/OAI/2.0/oai_dc/" xmlns:xsi="http://www.w3.org/2001/XMLSchema-instance" xsi:schemaLocation="http://www.openarchives.org/OAI/2.0/oai_dc/  http://www.openarchives.org/OAI/2.0/oai_dc.xsd">
	<dc:title xml:lang="en-US">Deep retino-network for automatic quantification of diabetic retinopathy</dc:title>
	<dc:creator>Amin Jameel, Syed</dc:creator>
	<dc:creator>Mohamed Shanavas, Abdul Rahim</dc:creator>
	<dc:subject xml:lang="en-US"></dc:subject>
	<dc:subject xml:lang="en-US">Classification system; Deep neural network; Diabetic retinopathy; Fundus image; Grading system</dc:subject>
	<dc:description xml:lang="en-US">Diabetic retinopathy (DR) is the ocular manifestation of the systemic disease. Since it is the most prevalent cause of blindness in the world, it demands a significant amount of therapeutic attention. As a result, a precise assessment of the DR condition as well as its evolution is very important for treatment. In this work, an automated quantification of diabetic retinopathy state (AQDRS) using fundus images is proposed. The state of DR is classified into 0 (low) to 3 (high) with the help of a deep retino-network (DRN). Before the classification by DRN, an image down-sampling scheme is employed. A DRN consists of convolution layer and max-pooling layers to extract the deep retina features and fully connected layer (FCL) for AQDRS where feed-forward neural network is employed for the classification. The performance of AQDRS by DRN for grading DR is evaluated using methods to evaluate segmentation and indexing techniques in the field of retinal ophthalmology (MESSIDOR) database. Results show that the AQDRS by DRN can able to extract the relevant discriminative information for grading the fundus image. The average accuracy on normal images in MESSIDOR database is 97.9% and it is 95.3% for DR images.</dc:description>
	<dc:publisher xml:lang="en-US">Institute of Advanced Engineering and Science</dc:publisher>
	<dc:contributor xml:lang="en-US"></dc:contributor>
	<dc:date>2024-09-01</dc:date>
	<dc:type>info:eu-repo/semantics/article</dc:type>
	<dc:type>info:eu-repo/semantics/publishedVersion</dc:type>
	<dc:type xml:lang="en-US"></dc:type>
	<dc:format>application/pdf</dc:format>
	<dc:identifier>https://ijai.iaescore.com/index.php/IJAI/article/view/24050</dc:identifier>
	<dc:identifier>10.11591/ijai.v13.i3.pp3306-3313</dc:identifier>
	<dc:source xml:lang="en-US">IAES International Journal of Artificial Intelligence (IJ-AI); Vol 13, No 3: September 2024; 3306-3313</dc:source>
	<dc:source>2252-8938</dc:source>
	<dc:source>2089-4872</dc:source>
	<dc:source>10.11591/ijai.v13.i3</dc:source>
	<dc:language>eng</dc:language>
	<dc:relation>https://ijai.iaescore.com/index.php/IJAI/article/view/24050/14183</dc:relation>
	<dc:rights xml:lang="en-US">Copyright (c) 2024 Institute of Advanced Engineering and Science</dc:rights>
	<dc:rights xml:lang="en-US">http://creativecommons.org/licenses/by-sa/4.0</dc:rights>
</oai_dc:dc>