Abstrak

Image quality in radiography is essential for diagnostic accuracy, yet reject–repeat analysis (RRA) is still mostly performed manually and depends on subjective radiographer judgment. Inter-operator variability leads to inconsistent quality data and limits workflow optimization. While many studies evaluate deep learning models for disease classification, research using convolutional neural networks (CNNs) to assess image quality and automate RRA remains limited. This study introduces a novel approach by applying CNNs to classify the causes of image rejection in chest radiography: positioning, exposure, artefacts, and accepted images, integrating these outcomes into a quality-management framework. The aim is to develop and evaluate CNN models (visual geometry group (VGG)-16, residual neural network (ResNet)-101, and dense convolutional network (DenseNet)-201) to support automated RRA using digital imaging and communications in medicine (DICOM)-based radiographs. The dataset comprised DICOM chest images annotated by a panel of radiologists, radiographers, and medical physicists into four technical classes. The CNNs were trained using supervised learning with structured training, validation, and testing splits, and evaluated using accuracy, precision, recall, and F1-score. Results show VGG-16 delivers the most stable and accurate performance across categories. Overall, CNNs effectively automate RRA with greater objectivity and consistency, reducing repeat rates, improving workflow efficiency, and strengthening radiology quality-management systems to enhance patient safety.

Kata kunci

Jaringan kolaborasi para penulis

29 penulis · 56 tautan kepenulisan bersama · 11 lintas organisasi

Arahkan kursor atau ketuk sebuah nama untuk menyorot rekan penulisnya. Klik dua kali untuk membuka halaman penulis.

  • Diponegoro University
  • National Research and Innovation Agency
  • National University of Singapore
  • Sebelas Maret University
  • Politeknik Negeri Semarang
  • Afiliasi tidak diketahui
  • Organisasi berbeda
  • Organisasi sama
  • Afiliasi tidak diketahui
  • Garis lebih tebal = lebih banyak artikel bersama · lingkaran lebih besar = lebih banyak artikel
Tampilkan sebagai tabel
Rekan penulisOrganisasiArtikel bersama
R. Rizal IsnantoDiponegoro University3
Esa PrakasaNational Research and Innovation Agency2
Tri Retnaningsih SoeprobowatiDiponegoro University2
Yulaikha MaratullatifahDiponegoro University2
Krisan Aprian WidagdoDiponegoro University1
Rahmat GernowoDiponegoro University1
Ucky Pradestha NovettralitaDiponegoro University1
Naufal BudimanAfiliasi tidak diketahui1
Adi WibowoNational University of Singapore1
Arie IswantiDiponegoro University1
N IdrusDiponegoro University1
Budi WarsitoDiponegoro University1
Sima MaulinaDiponegoro University1
Yuliani SetyaningsihDiponegoro University1
Dyah Dewi HastutiDiponegoro University1
Nanang SulaksonoDiponegoro University1
Arief Aulia RachmanNational Research and Innovation Agency1
Ovide Decroly Wisnu ArdhiSebelas Maret University1
Arief RachmanAfiliasi tidak diketahui1
Ovide Decroly Wisnu ArdhiAfiliasi tidak diketahui1
Cahya Tri PurnamiDiponegoro University1
Fila DelfiaDiponegoro University1
Farid AgushybanaDiponegoro University1
Kiki Puspita SariDiponegoro University1
Sirli FahriahDiponegoro University1
PrayitnoPoliteknik Negeri Semarang1

Afiliasi berasal dari OpenAlex; metadata OAI-PMH jurnal tidak memuatnya. Penulis tanpa ID OpenAlex dicocokkan berdasarkan nama, sehingga dua orang bisa tergabung atau satu orang bisa terpisah.

Sumber metadata: OAI-PMH (metadata jurnal) http://ijai.iaescore.com/index.php/IJAI/oai, pertama di-harvest 8 Nov 2026, terakhir terlihat 16 Nov 2026.
Metadata asli (oai_dc)
<oai_dc:dc xmlns="http://www.openarchives.org/OAI/2.0/" xmlns:dc="http://purl.org/dc/elements/1.1/" xmlns:oai_dc="http://www.openarchives.org/OAI/2.0/oai_dc/" xmlns:xsi="http://www.w3.org/2001/XMLSchema-instance" xsi:schemaLocation="http://www.openarchives.org/OAI/2.0/oai_dc/  http://www.openarchives.org/OAI/2.0/oai_dc.xsd">
	<dc:title xml:lang="en-US">Automated convolutional neural network-based reject–repeat decision system for chest radiographs</dc:title>
	<dc:creator>Rochmayanti, Dwi</dc:creator>
	<dc:creator>Adi, Kusworo</dc:creator>
	<dc:creator>Widodo, Catur Edi</dc:creator>
	<dc:subject xml:lang="en-US"></dc:subject>
	<dc:subject xml:lang="en-US">Chest radiography; Convolutional neural networks;  Image quality; Radiography; Reject-repeat analysis</dc:subject>
	<dc:description xml:lang="en-US">Image quality in radiography is essential for diagnostic accuracy, yet reject–repeat analysis (RRA) is still mostly performed manually and depends on subjective radiographer judgment. Inter-operator variability leads to inconsistent quality data and limits workflow optimization. While many studies evaluate deep learning models for disease classification, research using convolutional neural networks (CNNs) to assess image quality and automate RRA remains limited. This study introduces a novel approach by applying CNNs to classify the causes of image rejection in chest radiography: positioning, exposure, artefacts, and accepted images, integrating these outcomes into a quality-management framework. The aim is to develop and evaluate CNN models (visual geometry group (VGG)-16, residual neural network (ResNet)-101, and dense convolutional network (DenseNet)-201) to support automated RRA using digital imaging and communications in medicine (DICOM)-based radiographs. The dataset comprised DICOM chest images annotated by a panel of radiologists, radiographers, and medical physicists into four technical classes. The CNNs were trained using supervised learning with structured training, validation, and testing splits, and evaluated using accuracy, precision, recall, and F1-score. Results show VGG-16 delivers the most stable and accurate performance across categories. Overall, CNNs effectively automate RRA with greater objectivity and consistency, reducing repeat rates, improving workflow efficiency, and strengthening radiology quality-management systems to enhance patient safety.</dc:description>
	<dc:publisher xml:lang="en-US">Institute of Advanced Engineering and Science</dc:publisher>
	<dc:contributor xml:lang="en-US">Health Polytechnic of the Ministry of Health Semarang</dc:contributor>
	<dc:date>2026-10-01</dc:date>
	<dc:type>info:eu-repo/semantics/article</dc:type>
	<dc:type>info:eu-repo/semantics/publishedVersion</dc:type>
	<dc:type xml:lang="en-US"></dc:type>
	<dc:format>application/pdf</dc:format>
	<dc:identifier>https://ijai.iaescore.com/index.php/IJAI/article/view/31209</dc:identifier>
	<dc:identifier>10.11591/ijai.v15.i5.pp4121-4132</dc:identifier>
	<dc:source xml:lang="en-US">IAES International Journal of Artificial Intelligence (IJ-AI); Vol 15, No 5: October 2026; 4121-4132</dc:source>
	<dc:source>2252-8938</dc:source>
	<dc:source>2089-4872</dc:source>
	<dc:source>10.11591/ijai.v15.i5</dc:source>
	<dc:language>eng</dc:language>
	<dc:relation>https://ijai.iaescore.com/index.php/IJAI/article/view/31209/15382</dc:relation>
	<dc:rights xml:lang="en-US">Copyright (c) 2026 Dwi Rochmayanti, Kusworo Adi, Catur Edi Widodo</dc:rights>
	<dc:rights xml:lang="en-US">http://creativecommons.org/licenses/by-sa/4.0</dc:rights>
</oai_dc:dc>