Melola Discovery

← Melola Discovery

Akses terbuka Jurnal SINTA 1

Design and simulation of remote monitoring of the intelligent automatic control system in the production line

IAES International Journal of Artificial Intelligence · Vol. 13 No. 1 (2024) · hlm. 133–142

DOI
10.11591/ijai.v13.i1.pp133-142
ISSN
2252-8938, 2089-4872
Terbit
2024-03-01
Penerbit
Institute of Advanced Engineering and Science
Bahasa
eng
Lisensi
creativecommons.org/licenses/by-sa/4.0

Abstrak

In this research, we will introduce implementation requirements of a remote wireless control and monitoring unit of industrial production lines automatically controlled using programmable logic controller (PLC). PLC is capable of collecting different types of data and converting them into electrical signals that can be controlled by the industrial network using supervisory control and data acquisition (SCADA) systems. SCADA will be installed in the main server inside the control unit. The PLC will be used as a decision maker of the received signals for the industrial lines that comes from a group of detectors (sensors/transducers). The output of the PLC processor will trigger the engines, according to a specific industrial process management program. The processed data could be transferred through wireless or wired method. The wireless approach will be shown in this study, along with two other ways to implement it.

Kata kunci

Jaringan kolaborasi para penulis

7 penulis · 10 tautan kepenulisan bersama · 1 lintas organisasi

Arahkan kursor atau ketuk sebuah nama untuk menyorot rekan penulisnya. Klik dua kali untuk membuka halaman penulis.

  • Mustansiriyah University
  • Al-Esraa University
  • Organisasi berbeda
  • Organisasi sama
  • Afiliasi tidak diketahui
  • Garis lebih tebal = lebih banyak artikel bersama · lingkaran lebih besar = lebih banyak artikel
Tampilkan sebagai tabel
Rekan penulisOrganisasiArtikel bersama
Yasin Yousif Al‐AboosiMustansiriyah University2
Hussein Ali AbdulnabiMustansiriyah University2
Hamzah mohammed MarhoonAl-Esraa University1
Alaa Doohee YaseenMustansiriyah University1

Afiliasi berasal dari OpenAlex; metadata OAI-PMH jurnal tidak memuatnya. Penulis tanpa ID OpenAlex dicocokkan berdasarkan nama, sehingga dua orang bisa tergabung atau satu orang bisa terpisah.

Sumber metadata: OAI-PMH (metadata jurnal) http://ijai.iaescore.com/index.php/IJAI/oai, pertama di-harvest 8 Nov 2026, terakhir terlihat 22 Nov 2026.
Metadata asli (oai_dc)
<oai_dc:dc xmlns="http://www.openarchives.org/OAI/2.0/" xmlns:dc="http://purl.org/dc/elements/1.1/" xmlns:oai_dc="http://www.openarchives.org/OAI/2.0/oai_dc/" xmlns:xsi="http://www.w3.org/2001/XMLSchema-instance" xsi:schemaLocation="http://www.openarchives.org/OAI/2.0/oai_dc/  http://www.openarchives.org/OAI/2.0/oai_dc.xsd">
	<dc:title xml:lang="en-US">Design and simulation of remote monitoring of the intelligent automatic control system in the production line</dc:title>
	<dc:creator>Nasser, Amal Ibrahim</dc:creator>
	<dc:creator>Sahrab, Ammar Ali</dc:creator>
	<dc:creator>Kadhim, Hasan M.</dc:creator>
	<dc:subject xml:lang="en-US"></dc:subject>
	<dc:subject xml:lang="en-US">Actuator; Programmable logic controller; Sensor; Supervisory control and data acquisition; Zigbee;</dc:subject>
	<dc:description xml:lang="en-US">In this research, we will introduce implementation requirements of a remote wireless control and monitoring unit of industrial production lines automatically controlled using programmable logic controller (PLC). PLC is capable of collecting different types of data and converting them into electrical signals that can be controlled by the industrial network using supervisory control and data acquisition (SCADA) systems. SCADA will be installed in the main server inside the control unit. The PLC will be used as a decision maker of the received signals for the industrial lines that comes from a group of detectors (sensors/transducers). The output of the PLC processor will trigger the engines, according to a specific industrial process management program. The processed data could be transferred through wireless or wired method. The wireless approach will be shown in this study, along with two other ways to implement it.</dc:description>
	<dc:publisher xml:lang="en-US">Institute of Advanced Engineering and Science</dc:publisher>
	<dc:contributor xml:lang="en-US"></dc:contributor>
	<dc:date>2024-03-01</dc:date>
	<dc:type>info:eu-repo/semantics/article</dc:type>
	<dc:type>info:eu-repo/semantics/publishedVersion</dc:type>
	<dc:type xml:lang="en-US"></dc:type>
	<dc:format>application/pdf</dc:format>
	<dc:identifier>https://ijai.iaescore.com/index.php/IJAI/article/view/23028</dc:identifier>
	<dc:identifier>10.11591/ijai.v13.i1.pp133-142</dc:identifier>
	<dc:source xml:lang="en-US">IAES International Journal of Artificial Intelligence (IJ-AI); Vol 13, No 1: March 2024; 133-142</dc:source>
	<dc:source>2252-8938</dc:source>
	<dc:source>2089-4872</dc:source>
	<dc:source>10.11591/ijai.v13.i1</dc:source>
	<dc:language>eng</dc:language>
	<dc:relation>https://ijai.iaescore.com/index.php/IJAI/article/view/23028/13809</dc:relation>
	<dc:rights xml:lang="en-US">Copyright (c) 2023 Institute of Advanced Engineering and Science</dc:rights>
	<dc:rights xml:lang="en-US">http://creativecommons.org/licenses/by-sa/4.0</dc:rights>
</oai_dc:dc>