Akses terbuka
Jurnal
SINTA 1
Optimal Placement of SVC Using Fuzzy and Firefly Algorithm
IAES International Journal of Artificial Intelligence · Vol. 4 No. 4 (2015) · hlm. 113–117
ISSN 2252-8938, 2089-4872
Terbit 2015-12-01
Penerbit Institute of Advanced Engineering and Science
Bahasa eng
Abstrak
Voltage stability is major phenomena in any power system network for reliability and continuity operation. But the tight operation of power system due to overloading or fault on the system which is evitable and major threat to the power system. So it is necessary to maintain the voltages within the constraints at the overloading conditions also by placing of Static VAR Compensator (SVC) at optimal locations. New approaches are used to find the placement and size of the SVC at different locations. Fuzzy is used to find the location and the size of the SVC is fined by the Firefly algorithm. This paper considers different loading conditions of the power system network (125,150,175over loading conditions). From the results we can conclude that the power losses are reduced and the voltages can be maintained within the limits.IEEE 14 bus, IEEE 30 bus system is taken for the implementing the above techniques.
Jaringan kolaborasi para penulis
5 penulis ·
6 tautan kepenulisan bersama
Arahkan kursor atau ketuk sebuah nama untuk menyorot rekan penulisnya. Klik dua kali untuk membuka halaman penulis.
Jawaharlal Nehru Technological University Anantapur Afiliasi tidak diketahui
Organisasi berbeda
Organisasi sama
Afiliasi tidak diketahui
Garis lebih tebal = lebih banyak artikel bersama · lingkaran lebih besar = lebih banyak artikel
Tampilkan sebagai tabel
Afiliasi berasal dari OpenAlex; metadata OAI-PMH jurnal tidak memuatnya. Penulis tanpa ID OpenAlex dicocokkan berdasarkan nama, sehingga dua orang bisa tergabung atau satu orang bisa terpisah.
Sumber metadata: OAI-PMH (metadata jurnal) http://ijai.iaescore.com/index.php/IJAI/oai, pertama di-harvest 8 Nov 2026, terakhir terlihat 16 Nov 2026.
Metadata asli (oai_dc)
<oai_dc:dc xmlns="http://www.openarchives.org/OAI/2.0/" xmlns:dc="http://purl.org/dc/elements/1.1/" xmlns:oai_dc="http://www.openarchives.org/OAI/2.0/oai_dc/" xmlns:xsi="http://www.w3.org/2001/XMLSchema-instance" xsi:schemaLocation="http://www.openarchives.org/OAI/2.0/oai_dc/ http://www.openarchives.org/OAI/2.0/oai_dc.xsd">
<dc:title xml:lang="en-US">Optimal Placement of SVC Using Fuzzy and Firefly Algorithm</dc:title>
<dc:creator>BABU, P.SURESH</dc:creator>
<dc:creator>CHENNAIAH, P.B.</dc:creator>
<dc:creator>SREEHARI, M.</dc:creator>
<dc:subject xml:lang="en-US"></dc:subject>
<dc:subject xml:lang="en-US">Firefly algorithm, Fuzzy approach, SVC placement</dc:subject>
<dc:description xml:lang="en-US">Voltage stability is major phenomena in any power system network for reliability and continuity operation. But the tight operation of power system due to overloading or fault on the system which is evitable and major threat to the power system. So it is necessary to maintain the voltages within the constraints at the overloading conditions also by placing of Static VAR Compensator (SVC) at optimal locations. New approaches are used to find the placement and size of the SVC at different locations. Fuzzy is used to find the location and the size of the SVC is fined by the Firefly algorithm. This paper considers different loading conditions of the power system network (125,150,175over loading conditions). From the results we can conclude that the power losses are reduced and the voltages can be maintained within the limits .IEEE 14 bus, IEEE 30 bus system is taken for the implementing the above techniques.</dc:description>
<dc:publisher xml:lang="en-US">Institute of Advanced Engineering and Science</dc:publisher>
<dc:contributor xml:lang="en-US"></dc:contributor>
<dc:date>2015-12-01</dc:date>
<dc:type>info:eu-repo/semantics/article</dc:type>
<dc:type>info:eu-repo/semantics/publishedVersion</dc:type>
<dc:type xml:lang="en-US"></dc:type>
<dc:format>application/pdf</dc:format>
<dc:identifier>https://ijai.iaescore.com/index.php/IJAI/article/view/6122</dc:identifier>
<dc:identifier>10.11591/ijai.v4.i4.pp113-117</dc:identifier>
<dc:source xml:lang="en-US">IAES International Journal of Artificial Intelligence (IJ-AI); Vol 4, No 4: December 2015; 113-117</dc:source>
<dc:source>2252-8938</dc:source>
<dc:source>2089-4872</dc:source>
<dc:source>10.11591/ijai.v4.i4</dc:source>
<dc:language>eng</dc:language>
<dc:relation>https://ijai.iaescore.com/index.php/IJAI/article/view/6122/5828</dc:relation>
<dc:rights xml:lang="en-US">Copyright (c) 2015 Institute of Advanced Engineering and Science</dc:rights>
<dc:rights xml:lang="en-US">http://creativecommons.org/licenses/by-sa/4.0</dc:rights>
</oai_dc:dc>
Sitasi dan pengindeksan
Jumlah menurut tiap indeks pada 13 Nov 2026; setiap indeks menghitung sitasi dengan cara berbeda.
OpenAlex juga mencatat karya ini di: crossref.
Sitasi artikel ini
APA 7
BABU, P., CHENNAIAH, P., & SREEHARI, M. (2015). Optimal Placement of SVC Using Fuzzy and Firefly Algorithm. IAES International Journal of Artificial Intelligence, 4(4), 113–117. https://doi.org/10.11591/ijai.v4.i4.pp113-117
Salin
IEEE
P. BABU, P. CHENNAIAH, and M. SREEHARI, “Optimal Placement of SVC Using Fuzzy and Firefly Algorithm,” IAES International Journal of Artificial Intelligence, vol. 4, no. 4, pp. 113–117, 2015, doi: 10.11591/ijai.v4.i4.pp113-117.
Salin
Dibuat dari metadata jurnal; periksa nama penulis sebelum dipakai.