Melola Discovery

← Melola Discovery

Akses terbuka Jurnal SINTA 1

Fuzzy risk assessment system for indoor air quality and respiratory disease prevention

IAES International Journal of Artificial Intelligence · Vol. 14 No. 5 (2025) · hlm. 3693–3701

DOI
10.11591/ijai.v14.i5.pp3693-3701
ISSN
2252-8938, 2089-4872
Terbit
2025-10-01
Penerbit
Institute of Advanced Engineering and Science
Bahasa
eng
Lisensi
creativecommons.org/licenses/by-sa/4.0

Abstrak

This study addresses the evaluation of indoor air quality, with a focus on mitigating respiratory diseases and sick building syndrome (SBS). Recognizing that different pollutants exhibit variable behavior depending on environmental factors and human activity, the objective was to develop a fuzzy logic-based classification system that integrates environmental variables such as temperature, relative humidity, and pollutant concentrations‒particulate matter (PM10, PM2.5), carbon dioxide (CO₂), and total volatile organic compound (TVOC)‒into a unified model. The method involved defining risk levels as low, moderate, high, and very high, and implementing 54 fuzzy rules to dynamically and accurately categorize these risks, based on measurements taken between 2022 and 2024 in the states of Morelos and Puebla under various relative humidity and temperature scenarios. The analysis of the results demonstrated robust system performance, with an overall accuracy of 94.08%, but also revealed challenges in distinguishing between adjacent risk classes. This research contributes to a better understanding of the complex impacts of air quality on health and reinforces efforts to mitigate respiratory problems and SBS in densely populated indoor environments.

Kata kunci

Jaringan kolaborasi para penulis

5 penulis · 10 tautan kepenulisan bersama · 5 lintas organisasi

Arahkan kursor atau ketuk sebuah nama untuk menyorot rekan penulisnya. Klik dua kali untuk membuka halaman penulis.

  • Universidad Popular Autónoma del Estado de Puebla
  • Serviço Nacional de Aprendizagem Industrial
  • Universidad de Lima
  • Afiliasi tidak diketahui
  • Organisasi berbeda
  • Organisasi sama
  • Afiliasi tidak diketahui
  • Garis lebih tebal = lebih banyak artikel bersama · lingkaran lebih besar = lebih banyak artikel
Tampilkan sebagai tabel
Rekan penulisOrganisasiArtikel bersama

Afiliasi berasal dari OpenAlex; metadata OAI-PMH jurnal tidak memuatnya. Penulis tanpa ID OpenAlex dicocokkan berdasarkan nama, sehingga dua orang bisa tergabung atau satu orang bisa terpisah.

Sumber metadata: OAI-PMH (metadata jurnal) http://ijai.iaescore.com/index.php/IJAI/oai, pertama di-harvest 8 Nov 2026, terakhir terlihat 22 Nov 2026.
Metadata asli (oai_dc)
<oai_dc:dc xmlns="http://www.openarchives.org/OAI/2.0/" xmlns:dc="http://purl.org/dc/elements/1.1/" xmlns:oai_dc="http://www.openarchives.org/OAI/2.0/oai_dc/" xmlns:xsi="http://www.w3.org/2001/XMLSchema-instance" xsi:schemaLocation="http://www.openarchives.org/OAI/2.0/oai_dc/  http://www.openarchives.org/OAI/2.0/oai_dc.xsd">
	<dc:title xml:lang="en-US">Fuzzy risk assessment system for indoor air quality and respiratory disease prevention</dc:title>
	<dc:creator>Nunes, Éldman de Oliveira</dc:creator>
	<dc:creator>Barrera, Ariel Isaac Posada</dc:creator>
	<dc:creator>Peralta, Laura Margarita Rodríguez</dc:creator>
	<dc:creator>Sampaio, Paulo Nazareno Maia</dc:creator>
	<dc:creator>Astudillo, Fabián Leonardo Cuesta</dc:creator>
	<dc:subject xml:lang="en-US"></dc:subject>
	<dc:subject xml:lang="en-US">Environmental pollutants; Fuzzy logic; Indoor air quality; Risk classification; Sick building syndrome</dc:subject>
	<dc:description xml:lang="en-US">This study addresses the evaluation of indoor air quality, with a focus on mitigating respiratory diseases and sick building syndrome (SBS). Recognizing that different pollutants exhibit variable behavior depending on environmental factors and human activity, the objective was to develop a fuzzy logic-based classification system that integrates environmental variables such as temperature, relative humidity, and pollutant concentrations‒particulate matter (PM10, PM2.5), carbon dioxide (CO₂), and total volatile organic compound (TVOC)‒into a unified model. The method involved defining risk levels as low, moderate, high, and very high, and implementing 54 fuzzy rules to dynamically and accurately categorize these risks, based on measurements taken between 2022 and 2024 in the states of Morelos and Puebla under various relative humidity and temperature scenarios. The analysis of the results demonstrated robust system performance, with an overall accuracy of 94.08%, but also revealed challenges in distinguishing between adjacent risk classes. This research contributes to a better understanding of the complex impacts of air quality on health and reinforces efforts to mitigate respiratory problems and SBS in densely populated indoor environments.</dc:description>
	<dc:publisher xml:lang="en-US">Institute of Advanced Engineering and Science</dc:publisher>
	<dc:contributor xml:lang="en-US"></dc:contributor>
	<dc:date>2025-10-01</dc:date>
	<dc:type>info:eu-repo/semantics/article</dc:type>
	<dc:type>info:eu-repo/semantics/publishedVersion</dc:type>
	<dc:type xml:lang="en-US"></dc:type>
	<dc:format>application/pdf</dc:format>
	<dc:identifier>https://ijai.iaescore.com/index.php/IJAI/article/view/27238</dc:identifier>
	<dc:identifier>10.11591/ijai.v14.i5.pp3693-3701</dc:identifier>
	<dc:source xml:lang="en-US">IAES International Journal of Artificial Intelligence (IJ-AI); Vol 14, No 5: October 2025; 3693-3701</dc:source>
	<dc:source>2252-8938</dc:source>
	<dc:source>2089-4872</dc:source>
	<dc:source>10.11591/ijai.v14.i5</dc:source>
	<dc:language>eng</dc:language>
	<dc:relation>https://ijai.iaescore.com/index.php/IJAI/article/view/27238/14711</dc:relation>
	<dc:relation>https://ijai.iaescore.com/index.php/IJAI/article/downloadSuppFile/27238/4529</dc:relation>
	<dc:rights xml:lang="en-US">Copyright (c) 2025 Institute of Advanced Engineering and Science</dc:rights>
	<dc:rights xml:lang="en-US">http://creativecommons.org/licenses/by-sa/4.0</dc:rights>
</oai_dc:dc>