Abstrak

Dose distribution mapping is critical for guaranteeing correct sample irradiation, with both experimental and simulation methods playing important roles. Simulations are an effective way to forecast dose distribution patterns, lowering costs and increasing resource utilization. The geometry, source configuration, and measurement locations are fundamental to determine. The gamma irradiator has 48 source areas, each containing two cobalt-60 pencils measuring 8.15 cm, as well as a 4.7 cm stainless steel dummy. Alanine dosimeters were used for dose assessments, and stability varied by less than 1% over six months at 6°C and up to 5% at 50°C. The study's findings revealed a 2.25% disparity in relative dosage between experimental measurements and PHITS models. This result is a major improvement over prior research that found a 10% difference. Furthermore, dosage mapping along the XY and Z axes revealed the most uniform zone on the Z-axis, measuring 7.5 cm to 12.5 cm and with a radius of no more than 5 cm. These findings contribute to our understanding of dose distribution in gamma irradiation and highlight the utility of Monte Carlo simulations for optimizing irradiation operations. The study implies that this model can be used to improve the arrangement of cobalt-60 pencils in the irradiator, improving homogeneity and radiation outcomes.

Kata kunci

Jaringan kolaborasi para penulis

28 penulis · 85 tautan kepenulisan bersama · 40 lintas organisasi

Arahkan kursor atau ketuk sebuah nama untuk menyorot rekan penulisnya. Klik dua kali untuk membuka halaman penulis.

  • National Nuclear Energy Agency of Indonesia
  • National Research and Innovation Agency
  • University of Indonesia
  • Hasanuddin University
  • Kementerian Kesehatan Republik Indonesia
  • Sebelas Maret University
  • University of Malaya
  • Organisasi lain
  • Afiliasi tidak diketahui
  • Organisasi berbeda
  • Organisasi sama
  • Afiliasi tidak diketahui
  • Garis lebih tebal = lebih banyak artikel bersama · lingkaran lebih besar = lebih banyak artikel
Tampilkan sebagai tabel
Rekan penulisOrganisasiArtikel bersama
Eri HiswaraNational Nuclear Energy Agency of Indonesia5
Dewi KartikasariNational Nuclear Energy Agency of Indonesia5
K.Y.P. SandyNational Nuclear Energy Agency of Indonesia4
H. SofyanNational Nuclear Energy Agency of Indonesia3
Kwan Hoong NgUniversity of Malaya1
A. F. FirmansyahNational Nuclear Energy Agency of Indonesia1
Sunaryati Sri InangNational Nuclear Energy Agency of Indonesia1
M. Muharani PutriNational Research and Innovation Agency1
A. R. SetiadiAfiliasi tidak diketahui1
O. A. AkbarAfiliasi tidak diketahui1
V. ArifAfiliasi tidak diketahui1
C. AmeliaRumah Sakit Umum Pusat Sanglah Denpasar1
Dahlang TahirHasanuddin University1
Evi AfriantiHasanuddin University1
B.Y. Eko Budi JumpenoNational Nuclear Energy Agency of Indonesia1
June MellawatiNational Nuclear Energy Agency of Indonesia1
Nursama Heru ApriantoroKementerian Kesehatan Republik Indonesia1
Puji SupriyonoAfiliasi tidak diketahui1
Citra Elisabet SinagaKementerian Kesehatan Republik Indonesia1
I Gusti Ayu Ketut Rachmi HandayaniSebelas Maret University1
Hartiwiningsih HartiwiningsihSebelas Maret University1

Afiliasi berasal dari OpenAlex; metadata OAI-PMH jurnal tidak memuatnya. Penulis tanpa ID OpenAlex dicocokkan berdasarkan nama, sehingga dua orang bisa tergabung atau satu orang bisa terpisah.

Sumber metadata: OAI-PMH (metadata jurnal) https://jurnal.uns.ac.id/ijap/oai, pertama di-harvest 8 Nov 2026, terakhir terlihat 16 Nov 2026.
Metadata asli (oai_dc)
<oai_dc:dc xmlns="http://www.openarchives.org/OAI/2.0/" xmlns:dc="http://purl.org/dc/elements/1.1/" xmlns:oai_dc="http://www.openarchives.org/OAI/2.0/oai_dc/" xmlns:xsi="http://www.w3.org/2001/XMLSchema-instance" xsi:schemaLocation="http://www.openarchives.org/OAI/2.0/oai_dc/  http://www.openarchives.org/OAI/2.0/oai_dc.xsd">
	<dc:title xml:lang="en-US">Monte Carlo Simulation As Precision Predictive Tools to Find Isodose Curve of Gamma Irradiator: A Preliminary Study</dc:title>
	<dc:creator>Saputro, Bimo</dc:creator>
	<dc:creator>Saputro, Adhi Harmoko</dc:creator>
	<dc:creator>Nuraeni, Nunung</dc:creator>
	<dc:creator>Prasetio, Heru</dc:creator>
	<dc:creator>Firmansyah, Okky Agassy</dc:creator>
	<dc:creator>nugroho, Fendi</dc:creator>
	<dc:creator>Mayditia, Hasan</dc:creator>
	<dc:subject xml:lang="en-US">Dose distribution, experimental, gamma irradiator, simulation</dc:subject>
	<dc:description xml:lang="en-US">Dose distribution mapping is critical for guaranteeing correct sample irradiation, with both experimental and simulation methods playing important roles. Simulations are an effective way to forecast dose distribution patterns, lowering costs and increasing resource utilization. The geometry, source configuration, and measurement locations are fundamental to determine. The gamma irradiator has 48 source areas, each containing two cobalt-60 pencils measuring 8.15 cm, as well as a 4.7 cm stainless steel dummy. Alanine dosimeters were used for dose assessments, and stability varied by less than 1% over six months at 6°C and up to 5% at 50°C. The study's findings revealed a 2.25% disparity in relative dosage between experimental measurements and PHITS models. This result is a major improvement over prior research that found a 10% difference. Furthermore, dosage mapping along the XY and Z axes revealed the most uniform zone on the Z-axis, measuring 7.5 cm to 12.5 cm and with a radius of no more than 5 cm. These findings contribute to our understanding of dose distribution in gamma irradiation and highlight the utility of Monte Carlo simulations for optimizing irradiation operations. The study implies that this model can be used to improve the arrangement of cobalt-60 pencils in the irradiator, improving homogeneity and radiation outcomes.</dc:description>
	<dc:publisher xml:lang="en-US">Department of Physics, Sebelas Maret University</dc:publisher>
	<dc:contributor xml:lang="en-US">University of Indonesia, National Research and Innovation Agency (BRIN Indonesia)</dc:contributor>
	<dc:date>2024-11-01</dc:date>
	<dc:type>info:eu-repo/semantics/article</dc:type>
	<dc:type>info:eu-repo/semantics/publishedVersion</dc:type>
	<dc:type xml:lang="en-US">Peer-reviewed Article</dc:type>
	<dc:format>application/pdf</dc:format>
	<dc:identifier>https://jurnal.uns.ac.id/ijap/article/view/93092</dc:identifier>
	<dc:identifier>10.13057/ijap.v14i2.93092</dc:identifier>
	<dc:source xml:lang="en-US">INDONESIAN JOURNAL OF APPLIED PHYSICS; Vol 14, No 2 (2024): October; 386-398</dc:source>
	<dc:source>2477-6416</dc:source>
	<dc:source>2089-0133</dc:source>
	<dc:language>eng</dc:language>
	<dc:relation>https://jurnal.uns.ac.id/ijap/article/view/93092/47508</dc:relation>
	<dc:rights xml:lang="en-US">Copyright (c) 2024 INDONESIAN JOURNAL OF APPLIED PHYSICS</dc:rights>
</oai_dc:dc>