Melola Discovery

← Melola Discovery

Jurnal SINTA 1

Simulation Of Neutron Contamination From Medical Linac Using Particle And Heavy Ions Transport Code System (PHITS)

INDONESIAN JOURNAL OF APPLIED PHYSICS · Vol. 12 No. 2 (2022) · hlm. 258–265

DOI
10.13057/ijap.v12i2.60328
ISSN
2477-6416, 2089-0133
Terbit
2022-10-04
Penerbit
Department of Physics, Sebelas Maret University
Bahasa
eng

Abstrak

A research on neutron contamination in LINAC device has been carried out using a Monte Carlo method. The simulation is based on the Siemens Primus LINAC machine model whose component consists of target, primary collimator, flattening filter and secondary collimator as its main components. A neutron contamination examination was carried out using a 10 x 10 cm radiation field and a 100 cm SSD. Subsequently, at a distance of 100 cm from the X-ray source, a water phantom is placed. Investigation of the presence of contaminants was carried out the LINAC operating voltages of 6, 8, 10, 15, 18 and 25 MV. The simulation results show that neutron contamination occurs due to the interaction of photons with the components of the LINAC device, namely the primary collimator, flattening filter and secondary collimator. The operating voltages that can produce neutron contaminant start at 10 MV. Increase in the voltage of the LINAC device causes consequent increase in neutron flux. Such increase in neutron flux has the potential to increase therapeutic dose.

Kata kunci

Jaringan kolaborasi para penulis

28 penulis · 118 tautan kepenulisan bersama · 39 lintas organisasi

Arahkan kursor atau ketuk sebuah nama untuk menyorot rekan penulisnya. Klik dua kali untuk membuka halaman penulis.

  • Jenderal Soedirman University
  • Universitas Islam Negeri Ar-Raniry
  • Sumatera Institute of Technology
  • Universitas Negeri Padang
  • Hasanuddin University
  • National Nuclear Energy Agency of Indonesia
  • Nuclear Science and Technology Research Institute
  • Organisasi berbeda
  • Organisasi sama
  • Afiliasi tidak diketahui
  • Garis lebih tebal = lebih banyak artikel bersama · lingkaran lebih besar = lebih banyak artikel
Tampilkan sebagai tabel
Rekan penulisOrganisasiArtikel bersama
Dian Riana NingsihJenderal Soedirman University5
Zusfahair ZusfahairJenderal Soedirman University5
Amin FatoniJenderal Soedirman University4
Niken Istikhari MuslihahJenderal Soedirman University3
Yohannes SardjonoNational Nuclear Energy Agency of Indonesia2
Yaser KasesazNuclear Science and Technology Research Institute2
A. ArifinHasanuddin University1
Jamrud AminuddinJenderal Soedirman University1
Nurhayati NurhayatiUniversitas Islam Negeri Ar-Raniry1
Agustina WidiyaniSumatera Institute of Technology1
Mukhtar EffendiJenderal Soedirman University1
Abdullah Nur AzizJenderal Soedirman University1
Pakhrur RaziUniversitas Negeri Padang1
Wihantoro WihantoroJenderal Soedirman University1
Farzand AbdullatifJenderal Soedirman University1
Sunardi SunardiJenderal Soedirman University1
Aprilia Nafi NurainiJenderal Soedirman University1
Puji LestariJenderal Soedirman University1
Eva AryantiJenderal Soedirman University1
Aris SulistyowatiJenderal Soedirman University1
Ely SetiawanJenderal Soedirman University1
Purwati PurwatiJenderal Soedirman University1
Adilla LuthfiaJenderal Soedirman University1
Inessa Putri ApriliadinaJenderal Soedirman University1
Sifa Nurfadillah SetiawanJenderal Soedirman University1

Afiliasi berasal dari OpenAlex; metadata OAI-PMH jurnal tidak memuatnya. Penulis tanpa ID OpenAlex dicocokkan berdasarkan nama, sehingga dua orang bisa tergabung atau satu orang bisa terpisah.

Sumber metadata: OAI-PMH (metadata jurnal) https://jurnal.uns.ac.id/ijap/oai, pertama di-harvest 8 Nov 2026, terakhir terlihat 16 Nov 2026.
Metadata asli (oai_dc)
<oai_dc:dc xmlns="http://www.openarchives.org/OAI/2.0/" xmlns:dc="http://purl.org/dc/elements/1.1/" xmlns:oai_dc="http://www.openarchives.org/OAI/2.0/oai_dc/" xmlns:xsi="http://www.w3.org/2001/XMLSchema-instance" xsi:schemaLocation="http://www.openarchives.org/OAI/2.0/oai_dc/  http://www.openarchives.org/OAI/2.0/oai_dc.xsd">
	<dc:title xml:lang="en-US">Simulation Of Neutron Contamination From Medical Linac Using Particle And Heavy Ions Transport Code System (PHITS)</dc:title>
	<dc:creator>Bilalodin, Bilalodin</dc:creator>
	<dc:creator>Haryadi, Aris</dc:creator>
	<dc:creator>Haryanto, Bejo</dc:creator>
	<dc:subject xml:lang="en-US">Neutron contamination; Neutron flux;  LINAC; PHITS</dc:subject>
	<dc:description xml:lang="en-US">A research on neutron contamination in LINAC device has been carried out using a Monte Carlo method. The simulation is based on the Siemens Primus  LINAC machine model whose component consists of  target, primary collimator, flattening filter and secondary collimator as its main components. A neutron contamination examination was carried out using a 10 x 10 cm radiation field and a 100 cm SSD. Subsequently, at a distance of 100 cm from the X-ray source, a water phantom is placed. Investigation of the presence of contaminants was carried out the LINAC operating voltages of 6, 8, 10, 15, 18 and 25 MV. The simulation results show that neutron contamination occurs due to the interaction of photons with the components of the LINAC device, namely the primary collimator, flattening filter and secondary collimator. The operating voltages that can produce neutron contaminant start at 10 MV. Increase in the voltage of the LINAC device causes consequent increase in neutron flux. Such increase in neutron flux has the potential to increase therapeutic dose.</dc:description>
	<dc:publisher xml:lang="en-US">Department of Physics, Sebelas Maret University</dc:publisher>
	<dc:contributor xml:lang="en-US"></dc:contributor>
	<dc:date>2022-10-04</dc:date>
	<dc:type>info:eu-repo/semantics/article</dc:type>
	<dc:type>info:eu-repo/semantics/publishedVersion</dc:type>
	<dc:type xml:lang="en-US">Peer-reviewed Article</dc:type>
	<dc:format>application/pdf</dc:format>
	<dc:identifier>https://jurnal.uns.ac.id/ijap/article/view/60328</dc:identifier>
	<dc:identifier>10.13057/ijap.v12i2.60328</dc:identifier>
	<dc:source xml:lang="en-US">INDONESIAN JOURNAL OF APPLIED PHYSICS; Vol 12, No 2 (2022): October; 258-265</dc:source>
	<dc:source>2477-6416</dc:source>
	<dc:source>2089-0133</dc:source>
	<dc:language>eng</dc:language>
	<dc:relation>https://jurnal.uns.ac.id/ijap/article/view/60328/37690</dc:relation>
	<dc:rights xml:lang="en-US">Copyright (c) 2022 INDONESIAN JOURNAL OF APPLIED PHYSICS</dc:rights>
</oai_dc:dc>