Melola Discovery

← Melola Discovery

Jurnal SINTA 1

Design of Detection Device for Cu Contaminated WaterUsing Induction Principle

INDONESIAN JOURNAL OF APPLIED PHYSICS · Vol. 5 No. 01 (2015) · hlm. 79–85

DOI
10.13057/ijap.v5i01.266
ISSN
2477-6416, 2089-0133
Terbit
2015-12-16
Penerbit
Department of Physics, Sebelas Maret University
Bahasa
eng

Abstrak

The research on detection device design of Cu contaminated water using induction principle has been done. The purpose of this research is to create a detection device of Cu contaminated water using induction principle, characterize the precision of core sensor on detection device, characterize the stability of detection device, and implement the detection device to Cu contaminated water. This research was conducted in four phases: manufacturing of detection device, characterization of core sensor precision, characterization of detection devices stability, and implementation of detection device to Cu contaminated water. The results showed that the detection device of Cu contaminated water using induction principle has been successfully made. The precision of core sensor was 99.96%, while the stability of detection device was the 60th second after turn-on. The success rate of detection device implementation on Cu contaminated water was 100.00%.

Jaringan kolaborasi para penulis

6 penulis · 9 tautan kepenulisan bersama · 3 lintas organisasi

Arahkan kursor atau ketuk sebuah nama untuk menyorot rekan penulisnya. Klik dua kali untuk membuka halaman penulis.

  • Sunan Kalijaga State Islamic University Yogyakarta
  • Walisongo State Islamic University
  • Afiliasi tidak diketahui
  • Organisasi berbeda
  • Organisasi sama
  • Afiliasi tidak diketahui
  • Garis lebih tebal = lebih banyak artikel bersama · lingkaran lebih besar = lebih banyak artikel
Tampilkan sebagai tabel
Rekan penulisOrganisasiArtikel bersama
Heni SumartiWalisongo State Islamic University1
Anis YuniatiSunan Kalijaga State Islamic University Yogyakarta1
Bintang RamadhaniSunan Kalijaga State Islamic University Yogyakarta1

Afiliasi berasal dari OpenAlex; metadata OAI-PMH jurnal tidak memuatnya. Penulis tanpa ID OpenAlex dicocokkan berdasarkan nama, sehingga dua orang bisa tergabung atau satu orang bisa terpisah.

Sumber metadata: OAI-PMH (metadata jurnal) https://jurnal.uns.ac.id/ijap/oai, pertama di-harvest 8 Nov 2026, terakhir terlihat 16 Nov 2026.
Metadata asli (oai_dc)
<oai_dc:dc xmlns="http://www.openarchives.org/OAI/2.0/" xmlns:dc="http://purl.org/dc/elements/1.1/" xmlns:oai_dc="http://www.openarchives.org/OAI/2.0/oai_dc/" xmlns:xsi="http://www.w3.org/2001/XMLSchema-instance" xsi:schemaLocation="http://www.openarchives.org/OAI/2.0/oai_dc/  http://www.openarchives.org/OAI/2.0/oai_dc.xsd">
	<dc:title xml:lang="en-US">Design of Detection Device for Cu Contaminated WaterUsing Induction Principle</dc:title>
	<dc:creator>Rakhmadi, Frida Agung</dc:creator>
	<dc:creator>Dewi, Astika Rusma</dc:creator>
	<dc:creator>Azizi, Ahmad Farid</dc:creator>
	<dc:description xml:lang="en-US">The research on detection device design of Cu contaminated water using induction principle has been done. The purpose of this research is to create a detection device of Cu contaminated water using induction principle, characterize the precision of core sensor on detection device, characterize the stability of detection device, and implement the detection device to Cu contaminated water. This research was conducted in four phases: manufacturing of detection device, characterization of core sensor precision, characterization of detection devices stability, and implementation of detection device to Cu contaminated water. The results showed that the detection device of Cu contaminated water using induction principle has been successfully made. The precision of core sensor was 99.96%, while the stability of detection device was the 60th second after turn-on. The success rate of detection device implementation on Cu contaminated water was 100.00%.</dc:description>
	<dc:publisher xml:lang="en-US">Department of Physics, Sebelas Maret University</dc:publisher>
	<dc:contributor xml:lang="en-US"></dc:contributor>
	<dc:date>2015-12-16</dc:date>
	<dc:type>info:eu-repo/semantics/article</dc:type>
	<dc:type>info:eu-repo/semantics/publishedVersion</dc:type>
	<dc:type xml:lang="en-US">Peer-reviewed Article</dc:type>
	<dc:format>application/pdf</dc:format>
	<dc:identifier>https://jurnal.uns.ac.id/ijap/article/view/266</dc:identifier>
	<dc:identifier>10.13057/ijap.v5i01.266</dc:identifier>
	<dc:source xml:lang="en-US">INDONESIAN JOURNAL OF APPLIED PHYSICS; Vol 5, No 01 (2015): April; 79-85</dc:source>
	<dc:source>2477-6416</dc:source>
	<dc:source>2089-0133</dc:source>
	<dc:language>eng</dc:language>
	<dc:relation>https://jurnal.uns.ac.id/ijap/article/view/266/242</dc:relation>
	<dc:rights xml:lang="en-US">Copyright (c) 2015 INDONESIAN JOURNAL OF APPLIED PHYSICS</dc:rights>
</oai_dc:dc>