Melola Discovery

← Melola Discovery

Jurnal SINTA 1

Visual Analysis on Photoacoustic Emission Images of Synthetic Dye Contrast Agents inside a Simple Closed-Surface Phantom

INDONESIAN JOURNAL OF APPLIED PHYSICS · Vol. 15 No. 1 (2025) · hlm. 43–58

DOI
10.13057/ijap.v15i1.77839
ISSN
2477-6416, 2089-0133
Terbit
2025-05-04
Penerbit
Department of Physics, Sebelas Maret University
Bahasa
eng

Abstrak

A straightforward photoacoustic microscopy imaging system utilizing a laser diode emitting photons at wavelength of 450 nanometers was employed for visualizing contrast-enhanced phantom objects. These phantoms consist of polypropylene tubes with a diameter of 0.3 cm, infused with three types of dye solutions: methylene blue, methyl orange, and methyl red, at varying concentrations of 10 ppm, 25 ppm, 50 ppm, and 100 ppm. In total, twelve phantom objects were imaged, each positioned over a 1x1 cm imaging area constructed from composite galvalume plates. A condenser microphone with audiosonic frequency response was employed as the photoacoustic detector, capturing ones generated by the objects. These emissions were subsequently processed and transformed into two-dimensional polychromatic images. Three primary aspects govern the visual characteristics of each acquired image: (i) the visible light absorption capacity at 450 nanometers for each type of dye; (ii) the concentration of soluble dye molecules; and (iii) the geometry and shape of the polypropylene tube functioning as the closed-surface phantom. It was discovered that utilizing polypropylene tubes as the closed-surface phantom can hinder the propagation of photoacoustic emissions generated by the solution, leading to significantly lower measured photoacoustic intensity than expected. When combined with the intrinsic properties of the contrast agents used, this key factor ultimately shapes the image features obtained from this experiment.

Kata kunci

Jaringan kolaborasi para penulis

6 penulis · 8 tautan kepenulisan bersama · 5 lintas organisasi

Arahkan kursor atau ketuk sebuah nama untuk menyorot rekan penulisnya. Klik dua kali untuk membuka halaman penulis.

  • Universitas Gadjah Mada
  • Sam Ratulangi University
  • Sriwijaya University
  • Organisasi berbeda
  • Organisasi sama
  • Afiliasi tidak diketahui
  • Garis lebih tebal = lebih banyak artikel bersama · lingkaran lebih besar = lebih banyak artikel
Tampilkan sebagai tabel
Rekan penulisOrganisasiArtikel bersama
M.A.J. WasonoUniversitas Gadjah Mada2
Rini WidyaningrumUniversitas Gadjah Mada1
Miftahul JannaSriwijaya University1

Afiliasi berasal dari OpenAlex; metadata OAI-PMH jurnal tidak memuatnya. Penulis tanpa ID OpenAlex dicocokkan berdasarkan nama, sehingga dua orang bisa tergabung atau satu orang bisa terpisah.

Sumber metadata: OAI-PMH (metadata jurnal) https://jurnal.uns.ac.id/ijap/oai, pertama di-harvest 8 Nov 2026, terakhir terlihat 8 Nov 2026.
Metadata asli (oai_dc)
<oai_dc:dc xmlns="http://www.openarchives.org/OAI/2.0/" xmlns:dc="http://purl.org/dc/elements/1.1/" xmlns:oai_dc="http://www.openarchives.org/OAI/2.0/oai_dc/" xmlns:xsi="http://www.w3.org/2001/XMLSchema-instance" xsi:schemaLocation="http://www.openarchives.org/OAI/2.0/oai_dc/  http://www.openarchives.org/OAI/2.0/oai_dc.xsd">
	<dc:title xml:lang="en-US">Visual Analysis on Photoacoustic Emission Images of Synthetic Dye Contrast Agents inside a Simple Closed-Surface Phantom</dc:title>
	<dc:creator>Nugraha, Mahendra Kusuma</dc:creator>
	<dc:creator>Gani, Ernawatil</dc:creator>
	<dc:creator>Mitrayana, Mitrayana</dc:creator>
	<dc:subject xml:lang="en-US">photoacoustic microscopy; synthetic dye; closed-surface phantom; contrast agent.</dc:subject>
	<dc:description xml:lang="en-US">A straightforward photoacoustic microscopy imaging system utilizing a laser diode emitting photons at wavelength of 450 nanometers was employed for visualizing contrast-enhanced phantom objects. These phantoms consist of polypropylene tubes with a diameter of 0.3 cm, infused with three types of dye solutions: methylene blue, methyl orange, and methyl red, at varying concentrations of 10 ppm, 25 ppm, 50 ppm, and 100 ppm. In total, twelve phantom objects were imaged, each positioned over a 1x1 cm imaging area constructed from composite galvalume plates. A condenser microphone with audiosonic frequency response was employed as the photoacoustic detector, capturing ones generated by the objects. These emissions were subsequently processed and transformed into two-dimensional polychromatic images. Three primary aspects govern the visual characteristics of each acquired image: (i) the visible light absorption capacity at 450 nanometers for each type of dye; (ii) the concentration of soluble dye molecules; and (iii) the geometry and shape of the polypropylene tube functioning as the closed-surface phantom. It was discovered that utilizing polypropylene tubes as the closed-surface phantom can hinder the propagation of photoacoustic emissions generated by the solution, leading to significantly lower measured photoacoustic intensity than expected. When combined with the intrinsic properties of the contrast agents used, this key factor ultimately shapes the image features obtained from this experiment.</dc:description>
	<dc:publisher xml:lang="en-US">Department of Physics, Sebelas Maret University</dc:publisher>
	<dc:contributor xml:lang="en-US"></dc:contributor>
	<dc:date>2025-05-04</dc:date>
	<dc:type>info:eu-repo/semantics/article</dc:type>
	<dc:type>info:eu-repo/semantics/publishedVersion</dc:type>
	<dc:type xml:lang="en-US">Peer-reviewed Article</dc:type>
	<dc:format>application/pdf</dc:format>
	<dc:identifier>https://jurnal.uns.ac.id/ijap/article/view/77839</dc:identifier>
	<dc:identifier>10.13057/ijap.v15i1.77839</dc:identifier>
	<dc:source xml:lang="en-US">INDONESIAN JOURNAL OF APPLIED PHYSICS; Vol 15, No 1 (2025): April; 43-58</dc:source>
	<dc:source>2477-6416</dc:source>
	<dc:source>2089-0133</dc:source>
	<dc:language>eng</dc:language>
	<dc:relation>https://jurnal.uns.ac.id/ijap/article/view/77839/50041</dc:relation>
	<dc:rights xml:lang="en-US">Copyright (c) 2025 INDONESIAN JOURNAL OF APPLIED PHYSICS</dc:rights>
</oai_dc:dc>