Melola Discovery

← Melola Discovery

Jurnal SINTA 1

Pengaruh Pemberian Agen Kontras Pewarna Sintetik pada Jaringan Biologis terhadap Hasil Pencitraan Fotoakustik

INDONESIAN JOURNAL OF APPLIED PHYSICS · Vol. 12 No. 2 (2022) · hlm. 176–187

DOI
10.13057/ijap.v12i2.57219
ISSN
2477-6416, 2089-0133
Terbit
2022-10-04
Penerbit
Department of Physics, Sebelas Maret University
Bahasa
eng

Abstrak

An experiment to investigate the influence of synthetic dye contrast agent in photoacoustic imaging of biological tissue was conducted in this study. This study uses a simple phocoacoustic imaging system consists of three main components, i.e., a diode laser, condenser microphone, and a custom-build X-Y stage. Characterization was performed on the main components of the system to obtain the appropriate settings on imaging the biological tissue in this study. The results of the optimal frequency and duty cycle for laser modulation in this study were 19000 Hz and duty cyle of 40%, respectively. The addition of a contrast agent aims to improve the quality of the image by comparing the sample with methylene blue contrast agent, the sample with methyl red and the sample without contrast agent. The increases of acoustic intensity level is in proportion with the contrast agent concentration. The difference in the photoacoustic images reveal that the sample with methylene blue contrast agent has the highest acoustic intensity level compared to both sample with methyl red contrast agent and the sample without contrast agent. Therefore, this research proves that a photoacoustic imaging system can be developed to image biological tissue with a contrast agent and methylene blue has greater potential than methyl red to be used as a contrast agent in photoacoustic imaging.

Kata kunci

Jaringan kolaborasi para penulis

21 penulis · 48 tautan kepenulisan bersama · 8 lintas organisasi

Arahkan kursor atau ketuk sebuah nama untuk menyorot rekan penulisnya. Klik dua kali untuk membuka halaman penulis.

  • Universitas Gadjah Mada
  • Sriwijaya University
  • Sam Ratulangi University
  • Mulawarman University
  • Edith Cowan University
  • Afiliasi tidak diketahui
  • Organisasi berbeda
  • Organisasi sama
  • Afiliasi tidak diketahui
  • Garis lebih tebal = lebih banyak artikel bersama · lingkaran lebih besar = lebih banyak artikel
Tampilkan sebagai tabel
Rekan penulisOrganisasiArtikel bersama
Munakhir MudjosemediUniversitas Gadjah Mada2
Mahendra Kusuma NugrahaSam Ratulangi University2
Sabri SudirmanAfiliasi tidak diketahui2
Sabri SudirmanSriwijaya University2
Sri LestariMulawarman University1
Ferry JieEdith Cowan University1
Rurie Ratna ShantiningsihUniversitas Gadjah Mada1
Rona AulianisaUniversitas Gadjah Mada1
Isti Rahayu SuryaniUniversitas Gadjah Mada1
Nabila Almira RamadhaniUniversitas Gadjah Mada1
Rellyca Sola GraceaUniversitas Gadjah Mada1
Aini Hasibah NingtyasUniversitas Gadjah Mada1
Ernawatil GaniSam Ratulangi University1
M.A.J. WasonoUniversitas Gadjah Mada1
Erina ApriliaSriwijaya University1
Salman Khaerul HakimSriwijaya University1
Dwi Inda SariSriwijaya University1
Gama Dian NugrohoSriwijaya University1

Afiliasi berasal dari OpenAlex; metadata OAI-PMH jurnal tidak memuatnya. Penulis tanpa ID OpenAlex dicocokkan berdasarkan nama, sehingga dua orang bisa tergabung atau satu orang bisa terpisah.

Sumber metadata: OAI-PMH (metadata jurnal) https://jurnal.uns.ac.id/ijap/oai, pertama di-harvest 8 Nov 2026, terakhir terlihat 8 Nov 2026.
Metadata asli (oai_dc)
<oai_dc:dc xmlns="http://www.openarchives.org/OAI/2.0/" xmlns:dc="http://purl.org/dc/elements/1.1/" xmlns:oai_dc="http://www.openarchives.org/OAI/2.0/oai_dc/" xmlns:xsi="http://www.w3.org/2001/XMLSchema-instance" xsi:schemaLocation="http://www.openarchives.org/OAI/2.0/oai_dc/  http://www.openarchives.org/OAI/2.0/oai_dc.xsd">
	<dc:title xml:lang="en-US">Pengaruh Pemberian Agen Kontras Pewarna Sintetik pada Jaringan Biologis terhadap Hasil Pencitraan Fotoakustik</dc:title>
	<dc:creator>Janna, Miftahul</dc:creator>
	<dc:creator>Mitrayana, Mitrayana</dc:creator>
	<dc:creator>Widyaningrum, Rini</dc:creator>
	<dc:subject xml:lang="en-US">contrast agent, biological tissue, photoacoustic imaging, syntetic dye.</dc:subject>
	<dc:description xml:lang="en-US">An experiment to investigate the influence of synthetic dye contrast agent in photoacoustic imaging of biological tissue was conducted in this study. This study uses a simple phocoacoustic imaging system consists of three main components, i.e., a diode laser, condenser microphone, and a custom-build X-Y stage. Characterization was performed on the main components of the system to obtain the appropriate settings on imaging the biological tissue in this study. The results of the optimal frequency and duty cycle for laser modulation in this study were 19000 Hz and duty cyle of 40%, respectively. The addition of a contrast agent aims to improve the quality of the image by comparing the sample with methylene blue contrast agent, the sample with methyl red and the sample without contrast agent. The increases of acoustic intensity level is in proportion with the contrast agent concentration. The difference in the photoacoustic images reveal that the sample with methylene blue contrast agent has the highest acoustic intensity level compared to both sample with methyl red contrast agent and the sample without contrast agent. Therefore, this research proves that a photoacoustic imaging system can be developed to image biological tissue with a contrast agent and methylene blue has greater potential than methyl red to be used as a contrast agent in photoacoustic imaging.</dc:description>
	<dc:publisher xml:lang="en-US">Department of Physics, Sebelas Maret University</dc:publisher>
	<dc:contributor xml:lang="en-US"></dc:contributor>
	<dc:date>2022-10-04</dc:date>
	<dc:type>info:eu-repo/semantics/article</dc:type>
	<dc:type>info:eu-repo/semantics/publishedVersion</dc:type>
	<dc:type xml:lang="en-US">Peer-reviewed Article</dc:type>
	<dc:format>application/pdf</dc:format>
	<dc:identifier>https://jurnal.uns.ac.id/ijap/article/view/57219</dc:identifier>
	<dc:identifier>10.13057/ijap.v12i2.57219</dc:identifier>
	<dc:source xml:lang="en-US">INDONESIAN JOURNAL OF APPLIED PHYSICS; Vol 12, No 2 (2022): October; 176-187</dc:source>
	<dc:source>2477-6416</dc:source>
	<dc:source>2089-0133</dc:source>
	<dc:language>eng</dc:language>
	<dc:relation>https://jurnal.uns.ac.id/ijap/article/view/57219/37671</dc:relation>
	<dc:rights xml:lang="en-US">Copyright (c) 2022 INDONESIAN JOURNAL OF APPLIED PHYSICS</dc:rights>
</oai_dc:dc>