Melola Discovery

← Melola Discovery

Jurnal SINTA 1

Optimizing Formalin Detection in Fish Using QCM Sensors with TOMAC Membrane Coatings for Product Quality Monitoring

INDONESIAN JOURNAL OF APPLIED PHYSICS · Vol. 14 No. 2 (2024) · hlm. 377–385

DOI
10.13057/ijap.v14i2.92912
ISSN
2477-6416, 2089-0133
Terbit
2024-11-01
Penerbit
Department of Physics, Sebelas Maret University
Bahasa
eng

Abstrak

Detection of formalin in fishery products is a significant concern in the food industry to ensure consumer safety. This study compared the performance of Quartz Crystal Microbalance (QCM) sensors without a membrane and with a Trioctyl methyl ammonium Chloride (TOMAC) membrane coating in detecting formalin in fish samples. The research findings indicate that QCM without a membrane for formalin samples has a lower detection limit of 150 ppm and an upper detection limit of 350 ppm with a sensitivity of 2194.171 Hz/ppm. On the other hand, QCM with a TOMAC membrane coating has a lower detection limit of 400 ppm and an upper detection limit of 550 ppm with a sensitivity of 842.7551 Hz/ppm. Meanwhile, QCM without a membrane for formalin in fish samples has a lower detection limit of 450 ppm and an upper detection limit of 650 ppm with a sensitivity of 15386.38 Hz/ppm. At the same time, QCM with a TOMAC membrane coating for formalin in fish samples has a lower detection limit of 350 ppm and an upper detection limit of 500 ppm with a sensitivity of 23108.9 Hz/ppm. Response time analysis shows that both sensors reach a steady state condition after 12 seconds. This study highlights the importance of selecting appropriate sensors for detecting formalin in fishery products, considering detection limits, sensitivity, and response time as crucial criteria. Thus, these findings can guide the fisheries industry in choosing effective and accurate formalin detection technology.

Kata kunci

Jaringan kolaborasi para penulis

40 penulis · 103 tautan kepenulisan bersama · 39 lintas organisasi · menampilkan 40 yang paling banyak terhubung

Arahkan kursor atau ketuk sebuah nama untuk menyorot rekan penulisnya. Klik dua kali untuk membuka halaman penulis.

  • Universitas Islam Negeri Maulana Malik Ibrahim
  • Universitas Airlangga
  • Universitas Halu Oleo
  • National Research and Innovation Agency
  • Muhammadiyah University of Makassar
  • Hasanuddin University
  • Universitas Gadjah Mada
  • Organisasi lain
  • Organisasi berbeda
  • Organisasi sama
  • Afiliasi tidak diketahui
  • Garis lebih tebal = lebih banyak artikel bersama · lingkaran lebih besar = lebih banyak artikel
Tampilkan sebagai tabel
Rekan penulisOrganisasiArtikel bersama
Annisa Clara SalsabilaUniversitas Airlangga4
Ira NurmalaUniversitas Airlangga3
Muthmainnah MuthmainnahUniversitas Islam Negeri Maulana Malik Ibrahim2
Lutfi Agus SalimUniversitas Airlangga2
Jayanti Dian Eka SariUniversitas Airlangga2
Dedi RianaUniversitas Islam Negeri Maulana Malik Ibrahim1
Mohamad SyahadiNational Research and Innovation Agency1
Wiwis SasmitaninghidayahUniversitas Islam Negeri Maulana Malik Ibrahim1
Lia ApriliaNational Research and Innovation Agency1
Wildan Panji TresnaNational Research and Innovation Agency1
Iva Khuzaini KhasanahUniversitas Islam Negeri Maulana Malik Ibrahim1
Farid Samsu HanantoUniversitas Islam Negeri Maulana Malik Ibrahim1
Arista RomadaniUniversitas Islam Negeri Maulana Malik Ibrahim1
Agus MulyonoUniversitas Islam Negeri Maulana Malik Ibrahim1
Mokhamad TironoUniversitas Islam Negeri Maulana Malik Ibrahim1
Jafriati JafriatiUniversitas Halu Oleo1
Sri Tungga DewiUniversitas Halu Oleo1
Suhar SuharUniversitas Halu Oleo1
Hafiludin SamparadjaUniversitas Halu Oleo1
Irma SribiantiMuhammadiyah University of Makassar1
FauziahMuhammadiyah University of Makassar1
FauziahMuhammadiyah University of Makassar1
Marlina AchmadHasanuddin University1
Muhammad Yusri KarimHasanuddin University1
Mutmainnah MutmainnahUniversitas Halu Oleo1
Nur IsnainiUniversitas Islam Negeri Maulana Malik Ibrahim1
Avin AinurUniversitas Islam Negeri Maulana Malik Ibrahim1
Erna HastutiUniversitas Islam Negeri Maulana Malik Ibrahim1
Feny FefiyantiUniversitas Islam Negeri Maulana Malik Ibrahim1
Dwi SiswantaUniversitas Gadjah Mada1
Anis ChoiriyahUniversitas Islam Negeri Maulana Malik Ibrahim1
Kuwat TrıyanaUniversitas Gadjah Mada1
Asma NadiaUniversitas Airlangga1
Farapti FaraptiUniversitas Airlangga1
Dianna Suzieanna Mohamad ShahUniversiti Teknologi MARA1

Afiliasi berasal dari OpenAlex; metadata OAI-PMH jurnal tidak memuatnya. Penulis tanpa ID OpenAlex dicocokkan berdasarkan nama, sehingga dua orang bisa tergabung atau satu orang bisa terpisah.

Sumber metadata: OAI-PMH (metadata jurnal) https://jurnal.uns.ac.id/ijap/oai, pertama di-harvest 8 Nov 2026, terakhir terlihat 22 Nov 2026.
Metadata asli (oai_dc)
<oai_dc:dc xmlns="http://www.openarchives.org/OAI/2.0/" xmlns:dc="http://purl.org/dc/elements/1.1/" xmlns:oai_dc="http://www.openarchives.org/OAI/2.0/oai_dc/" xmlns:xsi="http://www.w3.org/2001/XMLSchema-instance" xsi:schemaLocation="http://www.openarchives.org/OAI/2.0/oai_dc/  http://www.openarchives.org/OAI/2.0/oai_dc.xsd">
	<dc:title xml:lang="en-US">Optimizing Formalin Detection in Fish Using QCM Sensors with TOMAC Membrane Coatings for Product Quality Monitoring</dc:title>
	<dc:creator>Muthmainnah, Muthmainnah</dc:creator>
	<dc:creator>Aini, Khoirul</dc:creator>
	<dc:creator>Tazi, Imam</dc:creator>
	<dc:creator>Chamidah, Ninik</dc:creator>
	<dc:creator>Kusairi, Kusairi</dc:creator>
	<dc:subject xml:lang="en-US">detection limit; lipid; Quartz Crystal; response time; sensitivity</dc:subject>
	<dc:description xml:lang="en-US">Detection of formalin in fishery products is a significant concern in the food industry to ensure consumer safety. This study compared the performance of Quartz Crystal Microbalance (QCM) sensors without a membrane and with a Trioctyl methyl ammonium Chloride (TOMAC) membrane coating in detecting formalin in fish samples. The research findings indicate that QCM without a membrane for formalin samples has a lower detection limit of 150 ppm and an upper detection limit of 350 ppm with a sensitivity of 2194.171 Hz/ppm. On the other hand, QCM with a TOMAC membrane coating has a lower detection limit of 400 ppm and an upper detection limit of 550 ppm with a sensitivity of 842.7551 Hz/ppm. Meanwhile, QCM without a membrane for formalin in fish samples has a lower detection limit of 450 ppm and an upper detection limit of 650 ppm with a sensitivity of 15386.38 Hz/ppm. At the same time, QCM with a TOMAC membrane coating for formalin in fish samples has a lower detection limit of 350 ppm and an upper detection limit of 500 ppm with a sensitivity of 23108.9 Hz/ppm. Response time analysis shows that both sensors reach a steady state condition after 12 seconds. This study highlights the importance of selecting appropriate sensors for detecting formalin in fishery products, considering detection limits, sensitivity, and response time as crucial criteria. Thus, these findings can guide the fisheries industry in choosing effective and accurate formalin detection technology.</dc:description>
	<dc:publisher xml:lang="en-US">Department of Physics, Sebelas Maret University</dc:publisher>
	<dc:contributor xml:lang="en-US"></dc:contributor>
	<dc:date>2024-11-01</dc:date>
	<dc:type>info:eu-repo/semantics/article</dc:type>
	<dc:type>info:eu-repo/semantics/publishedVersion</dc:type>
	<dc:type xml:lang="en-US">Peer-reviewed Article</dc:type>
	<dc:format>application/pdf</dc:format>
	<dc:identifier>https://jurnal.uns.ac.id/ijap/article/view/92912</dc:identifier>
	<dc:identifier>10.13057/ijap.v14i2.92912</dc:identifier>
	<dc:source xml:lang="en-US">INDONESIAN JOURNAL OF APPLIED PHYSICS; Vol 14, No 2 (2024): October; 377-385</dc:source>
	<dc:source>2477-6416</dc:source>
	<dc:source>2089-0133</dc:source>
	<dc:language>eng</dc:language>
	<dc:relation>https://jurnal.uns.ac.id/ijap/article/view/92912/47507</dc:relation>
	<dc:rights xml:lang="en-US">Copyright (c) 2024 INDONESIAN JOURNAL OF APPLIED PHYSICS</dc:rights>
</oai_dc:dc>