Jurnal
SINTA 1
Comparison of Dynamic Stability Response of A SMIB with PI and Fuzzy Controlled DPFC
Indonesian Journal of Electical Engineering and Informatics (IJEEI) · Vol. 5 No. 3 (2017) · hlm. 199–206
ISSN 2089-3272, 2089-3272
Terbit 2017-09-01
Penerbit IAES Indonesian Section
Bahasa en
Abstrak
Consumer utilities are non –linear in nature. This injects increased flow of current and reduced voltage with distortions which cause adverse effect on the stability of consumer utilities. To overcome this problem we are using a modern Flexible Alternating Current Transmission System controller i.e. distributed power flow controller (DPFC). This controller is similar to UPFC, which can be installed in a transmission line between the two electrical areas. In DPFC, instead of the common Dc link capacitor three single phase converters are used. In this paper we are concentrating on system stability (oscillation damping). For analyzing the stability of a single machine infinite bus system (SMIB) we have used PI controlled Distributed Power Flow Controller (DPFC) and Fuzzy controlled DPFC. All these models are simulated using MATLAB/SIMULINK. Simulation results shows Fuzzy controlled DPFC are better than PI controlled DPFC. The significance of the results are better stability and constant power supply.
Jaringan kolaborasi para penulis
4 penulis ·
4 tautan kepenulisan bersama
· 3 lintas organisasi
Arahkan kursor atau ketuk sebuah nama untuk menyorot rekan penulisnya. Klik dua kali untuk membuka halaman penulis.
Jodhpur National University Intel (United States) Jawaharlal Nehru Technological University Anantapur
Organisasi berbeda
Organisasi sama
Afiliasi tidak diketahui
Garis lebih tebal = lebih banyak artikel bersama · lingkaran lebih besar = lebih banyak artikel
Tampilkan sebagai tabel
Rekan penulis Organisasi Artikel bersama
K. Sudarsan Jawaharlal Nehru Technological University Anantapur 1
Afiliasi berasal dari OpenAlex; metadata OAI-PMH jurnal tidak memuatnya. Penulis tanpa ID OpenAlex dicocokkan berdasarkan nama, sehingga dua orang bisa tergabung atau satu orang bisa terpisah.
Sumber metadata: OAI-PMH (metadata jurnal) http://section.iaesonline.com/index.php/IJEEI/oai, pertama di-harvest 8 Nov 2026, terakhir terlihat 8 Nov 2026.
Metadata asli (oai_dc)
<oai_dc:dc xmlns="http://www.openarchives.org/OAI/2.0/" xmlns:dc="http://purl.org/dc/elements/1.1/" xmlns:oai_dc="http://www.openarchives.org/OAI/2.0/oai_dc/" xmlns:xsi="http://www.w3.org/2001/XMLSchema-instance" xsi:schemaLocation="http://www.openarchives.org/OAI/2.0/oai_dc/ http://www.openarchives.org/OAI/2.0/oai_dc.xsd">
<dc:title xml:lang="en">Comparison of Dynamic Stability Response of A SMIB with PI and Fuzzy Controlled DPFC</dc:title>
<dc:creator xml:lang="en">Srinivasarao, Budi</dc:creator>
<dc:creator xml:lang="en">Sreenivasan, G.</dc:creator>
<dc:creator xml:lang="en">Sharma, Swathi</dc:creator>
<dc:subject xml:lang="en">PI</dc:subject>
<dc:subject xml:lang="en">FUZZY</dc:subject>
<dc:subject xml:lang="en">DPFC</dc:subject>
<dc:subject xml:lang="en">dynamic stability</dc:subject>
<dc:subject xml:lang="en">SMIB</dc:subject>
<dc:description xml:lang="en">Consumer utilities are non –linear in nature. This injects increased flow of current and reduced voltage with distortions which cause adverse effect on the stability of consumer utilities. To overcome this problem we are using a modern Flexible Alternating Current Transmission System controller i.e. distributed power flow controller (DPFC). This controller is similar to UPFC, which can be installed in a transmission line between the two electrical areas. In DPFC, instead of the common Dc link capacitor three single phase converters are used. In this paper we are concentrating on system stability (oscillation damping). For analyzing the stability of a single machine infinite bus system (SMIB) we have used PI controlled Distributed Power Flow Controller (DPFC) and Fuzzy controlled DPFC. All these models are simulated using MATLAB/SIMULINK. Simulation results shows Fuzzy controlled DPFC are better than PI controlled DPFC. The significance of the results are better stability and constant power supply.</dc:description>
<dc:publisher xml:lang="en">IAES Indonesian Section</dc:publisher>
<dc:date>2017-09-01</dc:date>
<dc:type>info:eu-repo/semantics/article</dc:type>
<dc:type>info:eu-repo/semantics/publishedVersion</dc:type>
<dc:format>application/pdf</dc:format>
<dc:identifier>https://section.iaesonline.com/index.php/IJEEI/article/view/293</dc:identifier>
<dc:identifier>10.52549/ijeei.v5i3.293</dc:identifier>
<dc:source xml:lang="en">Indonesian Journal of Electrical Engineering and Informatics (IJEEI); Vol. 5 No. 3: September 2017; 199-206</dc:source>
<dc:source>2089-3272</dc:source>
<dc:source>2089-3272</dc:source>
<dc:language>en</dc:language>
<dc:relation>https://section.iaesonline.com/index.php/IJEEI/article/view/293/pdf</dc:relation>
</oai_dc:dc>
Sitasi dan pengindeksan
Jumlah menurut tiap indeks pada 13 Nov 2026; setiap indeks menghitung sitasi dengan cara berbeda.
OpenAlex juga mencatat karya ini di: crossref.
Sitasi artikel ini
APA 7
Srinivasarao, B., Sreenivasan, G., & Sharma, S. (2017). Comparison of Dynamic Stability Response of A SMIB with PI and Fuzzy Controlled DPFC. Indonesian Journal of Electical Engineering and Informatics (IJEEI), 5(3), 199–206. https://doi.org/10.52549/ijeei.v5i3.293
Salin
IEEE
B. Srinivasarao, G. Sreenivasan, and S. Sharma, “Comparison of Dynamic Stability Response of A SMIB with PI and Fuzzy Controlled DPFC,” Indonesian Journal of Electical Engineering and Informatics (IJEEI), vol. 5, no. 3, pp. 199–206, 2017, doi: 10.52549/ijeei.v5i3.293.
Salin
Dibuat dari metadata jurnal; periksa nama penulis sebelum dipakai.