Melola Discovery

← Melola Discovery

Jurnal SINTA 1

Feature and muscle selection for an effective hand motion classifier based on electromyography

Indonesian Journal of Electical Engineering and Informatics (IJEEI) · Vol. 7 No. 2 (2019) · hlm. 303–313

DOI
10.52549/ijeei.v7i2.867
ISSN
2089-3272, 2089-3272
Terbit
2019-05-20
Penerbit
IAES Indonesian Section
Bahasa
en

Abstrak

An issue that arises in the hand motion classification based on the electromyography (EMG) system is the failure of choosing the right features and number of muscles. These parameters are fundamental in determining the accuracy and effectiveness of the classifier system. Therefore, the objective of this study is to develop and evaluate an effective hand motion classifier based on the EMG signal. The three-channel of EMG was collected by placing three pairs of electrodes on the surface of the skin. Six statistic features (mean, variance, standard deviation, kurtosis, skewness, and entropy) were selected to extract the EMG signal using a window length of 100 samples. A muscle and features selection is applied to the classifier machine (linear discriminant analysis (LDA), support vector machine (SVM) and K nearest neighborhood (KNN)) to retrieve the most useful feature and muscle. In this study, we found that there was no significant difference in accuracy among a number of muscles (p-value>0.05). LDA and SVM showed the best accuracy and no significant difference in accuracy between both were found. This study concluded that EMG signal from a single muscle can classify the hand motion (hand close, open, wrist flexion, and extension) effectively.

Kata kunci

Jaringan kolaborasi para penulis

23 penulis · 58 tautan kepenulisan bersama · 19 lintas organisasi

Arahkan kursor atau ketuk sebuah nama untuk menyorot rekan penulisnya. Klik dua kali untuk membuka halaman penulis.

  • Poltekkes Kemenkes Surabaya
  • Rumah Sakit Dokter Soetomo
  • Universiti Brunei Darussalam
  • Bani-Waleed University
  • Universitas Airlangga
  • Poltekkes Kemenkes Malang
  • Azerbaijan State Oil and Industry University
  • Organisasi lain
  • Afiliasi tidak diketahui
  • Organisasi berbeda
  • Organisasi sama
  • Afiliasi tidak diketahui
  • Garis lebih tebal = lebih banyak artikel bersama · lingkaran lebih besar = lebih banyak artikel
Tampilkan sebagai tabel
Rekan penulisOrganisasiArtikel bersama
Wahyu CaesarendraUniversiti Brunei Darussalam2
Sari LuthfiyahPoltekkes Kemenkes Surabaya2
Abdussalam Ali AhmedBani-Waleed University2
Endro YuliantoPoltekkes Kemenkes Surabaya1
Umaimah Mitsalia Ummi SalwaUniversitas Airlangga1
Tri Bowo IndartoPoltekkes Kemenkes Surabaya1
Bedjo UtomoPoltekkes Kemenkes Surabaya1
Sugeng Iwan SetyobudiPoltekkes Kemenkes Malang1
Sumber SumberPoltekkes Kemenkes Surabaya1
Endang Dian SetioningsihPoltekkes Kemenkes Surabaya1
Roichatun NashichahPoltekkes Kemenkes Surabaya1
Vijay Anant AthavaleAfiliasi tidak diketahui1
Herianto HeriantoUniversitas Gadjah Mada1
Vugar Hajimahmud AbdullayevAzerbaijan State Oil and Industry University1
Vugar AbdullayevAfiliasi tidak diketahui1
Abd KholiqAfiliasi tidak diketahui1
Lamidi LamidiAfiliasi tidak diketahui1
Farid AmrinsaniAfiliasi tidak diketahui1
Hafizh Aushaf MahdyAfiliasi tidak diketahui1
Ragimova NazilaAfiliasi tidak diketahui1

Afiliasi berasal dari OpenAlex; metadata OAI-PMH jurnal tidak memuatnya. Penulis tanpa ID OpenAlex dicocokkan berdasarkan nama, sehingga dua orang bisa tergabung atau satu orang bisa terpisah.

Sumber metadata: OAI-PMH (metadata jurnal) http://section.iaesonline.com/index.php/IJEEI/oai, pertama di-harvest 8 Nov 2026, terakhir terlihat 8 Nov 2026.
Metadata asli (oai_dc)
<oai_dc:dc xmlns="http://www.openarchives.org/OAI/2.0/" xmlns:dc="http://purl.org/dc/elements/1.1/" xmlns:oai_dc="http://www.openarchives.org/OAI/2.0/oai_dc/" xmlns:xsi="http://www.w3.org/2001/XMLSchema-instance" xsi:schemaLocation="http://www.openarchives.org/OAI/2.0/oai_dc/  http://www.openarchives.org/OAI/2.0/oai_dc.xsd">
	<dc:title xml:lang="en">Feature and muscle selection for an effective hand motion classifier based on electromyography</dc:title>
	<dc:creator xml:lang="en">Triwiyanto, Triwiyanto</dc:creator>
	<dc:creator xml:lang="en">Rahmawati, Triana</dc:creator>
	<dc:creator xml:lang="en">Pawana, I Putu Alit</dc:creator>
	<dc:subject xml:lang="en">Electromyography</dc:subject>
	<dc:subject xml:lang="en">KNN</dc:subject>
	<dc:subject xml:lang="en">LDA</dc:subject>
	<dc:subject xml:lang="en">Pattern recognition</dc:subject>
	<dc:subject xml:lang="en">Statistic features</dc:subject>
	<dc:subject xml:lang="en">SVM</dc:subject>
	<dc:description xml:lang="en">An issue that arises in the hand motion classification based on the electromyography (EMG) system is the failure of choosing the right features and number of muscles. These parameters are fundamental in determining the accuracy and effectiveness of the classifier system. Therefore, the objective of this study is to develop and evaluate an effective hand motion classifier based on the EMG signal. The three-channel of EMG was collected by placing three pairs of electrodes on the surface of the skin. Six statistic features (mean, variance, standard deviation, kurtosis, skewness, and entropy) were selected to extract the EMG signal using a window length of 100 samples. A muscle and features selection is applied to the classifier machine (linear discriminant analysis (LDA), support vector machine (SVM) and K nearest neighborhood (KNN)) to retrieve the most useful feature and muscle. In this study, we found that there was no significant difference in accuracy among a number of muscles (p-value&amp;gt;0.05). LDA and SVM showed the best accuracy and no significant difference in accuracy between both were found. This study concluded that EMG signal from a single muscle can classify the hand motion (hand close, open, wrist flexion, and extension) effectively. </dc:description>
	<dc:publisher xml:lang="en">IAES Indonesian Section</dc:publisher>
	<dc:date>2019-05-20</dc:date>
	<dc:type>info:eu-repo/semantics/article</dc:type>
	<dc:type>info:eu-repo/semantics/publishedVersion</dc:type>
	<dc:format>application/pdf</dc:format>
	<dc:identifier>https://section.iaesonline.com/index.php/IJEEI/article/view/867</dc:identifier>
	<dc:identifier>10.52549/ijeei.v7i2.867</dc:identifier>
	<dc:source xml:lang="en">Indonesian Journal of Electrical Engineering and Informatics (IJEEI); Vol. 7 No. 2: June 2019; 303-313</dc:source>
	<dc:source>2089-3272</dc:source>
	<dc:source>2089-3272</dc:source>
	<dc:language>en</dc:language>
	<dc:relation>https://section.iaesonline.com/index.php/IJEEI/article/view/867/421</dc:relation>
</oai_dc:dc>