Jurnal
SINTA 1
Modeling and simulation of a wirelessly-powered thermopneumatic micropump for drug delivery applications
Indonesian Journal of Electical Engineering and Informatics (IJEEI) · Vol. 7 No. 2 (2019) · hlm. 182–189
ISSN 2089-3272, 2089-3272
Terbit 2019-05-20
Penerbit IAES Indonesian Section
Bahasa en
Abstrak
This paper presents modeling and finite element analysis of a thermopneumatic micropump with a novel design that does not affect the temperature of the working fluid. The micropump is operated by activating a passive wireless heater using wireless power transfer when the magnetic field is tuned to match the resonant frequency of the heater. The heater is responsible for heating an air-heating chamber that is connected to a loading reservoir through a microdiffuser element. The solution inside the reservoir is pumped through a microchannel that ends with an outlet hole. The thermal and pumping performances of the micropump are analyzed using finite element method over a low range of Reynold’s number ⩽ 10 that is suitable for various biomedical applications. The results demonstrate promising performance with a maximum flow rate of ∼2.86 μL/min at a chamber temperature of 42.5 ºC, and a maximum pumping pressure of 406.5 Pa. The results show that the developed device can be potentially implemented in various biomedical areas, such as implantable drug delivery applications.
Jaringan kolaborasi para penulis
7 penulis ·
12 tautan kepenulisan bersama
· 1 lintas organisasi
Arahkan kursor atau ketuk sebuah nama untuk menyorot rekan penulisnya. Klik dua kali untuk membuka halaman penulis.
University of Technology Malaysia University of Nottingham Afiliasi tidak diketahui
Organisasi berbeda
Organisasi sama
Afiliasi tidak diketahui
Garis lebih tebal = lebih banyak artikel bersama · lingkaran lebih besar = lebih banyak artikel
Tampilkan sebagai tabel
Afiliasi berasal dari OpenAlex; metadata OAI-PMH jurnal tidak memuatnya. Penulis tanpa ID OpenAlex dicocokkan berdasarkan nama, sehingga dua orang bisa tergabung atau satu orang bisa terpisah.
Sumber metadata: OAI-PMH (metadata jurnal) http://section.iaesonline.com/index.php/IJEEI/oai, pertama di-harvest 8 Nov 2026, terakhir terlihat 8 Nov 2026.
Metadata asli (oai_dc)
<oai_dc:dc xmlns="http://www.openarchives.org/OAI/2.0/" xmlns:dc="http://purl.org/dc/elements/1.1/" xmlns:oai_dc="http://www.openarchives.org/OAI/2.0/oai_dc/" xmlns:xsi="http://www.w3.org/2001/XMLSchema-instance" xsi:schemaLocation="http://www.openarchives.org/OAI/2.0/oai_dc/ http://www.openarchives.org/OAI/2.0/oai_dc.xsd">
<dc:title xml:lang="en">Modeling and simulation of a wirelessly-powered thermopneumatic micropump for drug delivery applications</dc:title>
<dc:creator xml:lang="en">Nafea, Marwan</dc:creator>
<dc:creator xml:lang="en">Baliah, Jeevananthan</dc:creator>
<dc:creator xml:lang="en">Ali, Mohamed Sultan Mohamed</dc:creator>
<dc:subject xml:lang="en">Drug delivery</dc:subject>
<dc:subject xml:lang="en">Microfluidic</dc:subject>
<dc:subject xml:lang="en">Micropump</dc:subject>
<dc:subject xml:lang="en">Thermopneumatic</dc:subject>
<dc:subject xml:lang="en">Wireless power transfer</dc:subject>
<dc:description xml:lang="en">This paper presents modeling and finite element analysis of a thermopneumatic micropump with a novel design that does not affect the temperature of the working fluid. The micropump is operated by activating a passive wireless heater using wireless power transfer when the magnetic field is tuned to match the resonant frequency of the heater. The heater is responsible for heating an air-heating chamber that is connected to a loading reservoir through a microdiffuser element. The solution inside the reservoir is pumped through a microchannel that ends with an outlet hole. The thermal and pumping performances of the micropump are analyzed using finite element method over a low range of Reynold’s number ⩽ 10 that is suitable for various biomedical applications. The results demonstrate promising performance with a maximum flow rate of ∼2.86 μL/min at a chamber temperature of 42.5 ºC, and a maximum pumping pressure of 406.5 Pa. The results show that the developed device can be potentially implemented in various biomedical areas, such as implantable drug delivery applications.</dc:description>
<dc:publisher xml:lang="en">IAES Indonesian Section</dc:publisher>
<dc:date>2019-05-20</dc:date>
<dc:type>info:eu-repo/semantics/article</dc:type>
<dc:type>info:eu-repo/semantics/publishedVersion</dc:type>
<dc:format>application/pdf</dc:format>
<dc:identifier>https://section.iaesonline.com/index.php/IJEEI/article/view/1175</dc:identifier>
<dc:identifier>10.52549/ijeei.v7i2.1175</dc:identifier>
<dc:source xml:lang="en">Indonesian Journal of Electrical Engineering and Informatics (IJEEI); Vol. 7 No. 2: June 2019; 182-189</dc:source>
<dc:source>2089-3272</dc:source>
<dc:source>2089-3272</dc:source>
<dc:language>en</dc:language>
<dc:relation>https://section.iaesonline.com/index.php/IJEEI/article/view/1175/410</dc:relation>
</oai_dc:dc>
Sitasi dan pengindeksan
Jumlah menurut tiap indeks pada 13 Nov 2026; setiap indeks menghitung sitasi dengan cara berbeda.
OpenAlex juga mencatat karya ini di: crossref.
Sitasi artikel ini
APA 7
Nafea, M., Baliah, J., & Ali, M. S. M. (2019). Modeling and simulation of a wirelessly-powered thermopneumatic micropump for drug delivery applications. Indonesian Journal of Electical Engineering and Informatics (IJEEI), 7(2), 182–189. https://doi.org/10.52549/ijeei.v7i2.1175
Salin
IEEE
M. Nafea, J. Baliah, and M. S. M. Ali, “Modeling and simulation of a wirelessly-powered thermopneumatic micropump for drug delivery applications,” Indonesian Journal of Electical Engineering and Informatics (IJEEI), vol. 7, no. 2, pp. 182–189, 2019, doi: 10.52549/ijeei.v7i2.1175.
Salin
Dibuat dari metadata jurnal; periksa nama penulis sebelum dipakai.