Melola Discovery

← Melola Discovery

Jurnal SINTA 1

Modeling and simulation of a wirelessly-powered thermopneumatic micropump for drug delivery applications

Indonesian Journal of Electical Engineering and Informatics (IJEEI) · Vol. 7 No. 2 (2019) · hlm. 182–189

DOI
10.52549/ijeei.v7i2.1175
ISSN
2089-3272, 2089-3272
Terbit
2019-05-20
Penerbit
IAES Indonesian Section
Bahasa
en

Abstrak

This paper presents modeling and finite element analysis of a thermopneumatic micropump with a novel design that does not affect the temperature of the working fluid. The micropump is operated by activating a passive wireless heater using wireless power transfer when the magnetic field is tuned to match the resonant frequency of the heater. The heater is responsible for heating an air-heating chamber that is connected to a loading reservoir through a microdiffuser element. The solution inside the reservoir is pumped through a microchannel that ends with an outlet hole. The thermal and pumping performances of the micropump are analyzed using finite element method over a low range of Reynold’s number ⩽ 10 that is suitable for various biomedical applications. The results demonstrate promising performance with a maximum flow rate of ∼2.86 μL/min at a chamber temperature of 42.5 ºC, and a maximum pumping pressure of 406.5 Pa. The results show that the developed device can be potentially implemented in various biomedical areas, such as implantable drug delivery applications.

Kata kunci

Jaringan kolaborasi para penulis

7 penulis · 12 tautan kepenulisan bersama · 1 lintas organisasi

Arahkan kursor atau ketuk sebuah nama untuk menyorot rekan penulisnya. Klik dua kali untuk membuka halaman penulis.

  • University of Technology Malaysia
  • University of Nottingham
  • Afiliasi tidak diketahui
  • Organisasi berbeda
  • Organisasi sama
  • Afiliasi tidak diketahui
  • Garis lebih tebal = lebih banyak artikel bersama · lingkaran lebih besar = lebih banyak artikel
Tampilkan sebagai tabel
Rekan penulisOrganisasiArtikel bersama
Farah Afiqa Mohd GhazaliUniversity of Technology Malaysia2
Mariatul Rawdhah Ahmad FuaadUniversity of Technology Malaysia2
Wong Yi JieAfiliasi tidak diketahui1
Lee Chang YangAfiliasi tidak diketahui1

Afiliasi berasal dari OpenAlex; metadata OAI-PMH jurnal tidak memuatnya. Penulis tanpa ID OpenAlex dicocokkan berdasarkan nama, sehingga dua orang bisa tergabung atau satu orang bisa terpisah.

Sumber metadata: OAI-PMH (metadata jurnal) http://section.iaesonline.com/index.php/IJEEI/oai, pertama di-harvest 8 Nov 2026, terakhir terlihat 8 Nov 2026.
Metadata asli (oai_dc)
<oai_dc:dc xmlns="http://www.openarchives.org/OAI/2.0/" xmlns:dc="http://purl.org/dc/elements/1.1/" xmlns:oai_dc="http://www.openarchives.org/OAI/2.0/oai_dc/" xmlns:xsi="http://www.w3.org/2001/XMLSchema-instance" xsi:schemaLocation="http://www.openarchives.org/OAI/2.0/oai_dc/  http://www.openarchives.org/OAI/2.0/oai_dc.xsd">
	<dc:title xml:lang="en">Modeling and simulation of a wirelessly-powered thermopneumatic micropump for drug delivery applications</dc:title>
	<dc:creator xml:lang="en">Nafea, Marwan</dc:creator>
	<dc:creator xml:lang="en">Baliah, Jeevananthan</dc:creator>
	<dc:creator xml:lang="en">Ali, Mohamed Sultan Mohamed</dc:creator>
	<dc:subject xml:lang="en">Drug delivery</dc:subject>
	<dc:subject xml:lang="en">Microfluidic</dc:subject>
	<dc:subject xml:lang="en">Micropump</dc:subject>
	<dc:subject xml:lang="en">Thermopneumatic</dc:subject>
	<dc:subject xml:lang="en">Wireless power transfer</dc:subject>
	<dc:description xml:lang="en">This paper presents modeling and finite element analysis of a thermopneumatic micropump with a novel design that does not affect the temperature of the working fluid. The micropump is operated by activating a passive wireless heater using wireless power transfer when the magnetic field is tuned to match the resonant frequency of the heater. The heater is responsible for heating an air-heating chamber that is connected to a loading reservoir through a microdiffuser element. The solution inside the reservoir is pumped through a microchannel that ends with an outlet hole. The thermal and pumping performances of the micropump are analyzed using finite element method over a low range of Reynold’s number ⩽ 10 that is suitable for various biomedical applications. The results demonstrate promising performance with a maximum flow rate of ∼2.86 μL/min at a chamber temperature of 42.5 ºC, and a maximum pumping pressure of 406.5 Pa. The results show that the developed device can be potentially implemented in various biomedical areas, such as implantable drug delivery applications.</dc:description>
	<dc:publisher xml:lang="en">IAES Indonesian Section</dc:publisher>
	<dc:date>2019-05-20</dc:date>
	<dc:type>info:eu-repo/semantics/article</dc:type>
	<dc:type>info:eu-repo/semantics/publishedVersion</dc:type>
	<dc:format>application/pdf</dc:format>
	<dc:identifier>https://section.iaesonline.com/index.php/IJEEI/article/view/1175</dc:identifier>
	<dc:identifier>10.52549/ijeei.v7i2.1175</dc:identifier>
	<dc:source xml:lang="en">Indonesian Journal of Electrical Engineering and Informatics (IJEEI); Vol. 7 No. 2: June 2019; 182-189</dc:source>
	<dc:source>2089-3272</dc:source>
	<dc:source>2089-3272</dc:source>
	<dc:language>en</dc:language>
	<dc:relation>https://section.iaesonline.com/index.php/IJEEI/article/view/1175/410</dc:relation>
</oai_dc:dc>