Melola Discovery

← Melola Discovery

Jurnal SINTA 1

Design of a Lightning Protection System for an Overhead 3 kV DC Electrified Railway Line: A Case Study from South Africa

Indonesian Journal of Electical Engineering and Informatics (IJEEI) · Vol. 9 No. 2 (2021) · hlm. 346–359

DOI
10.52549/ijeei.v9i2.2935
ISSN
2089-3272, 2089-3272
Terbit
2021-06-10
Penerbit
IAES Indonesian Section
Bahasa
en

Abstrak

A protection scheme is proposed for the 3 kV DC railway, in Kwa-Zulu Natal province, a region with a high lightning occurrence density. The surge protection was sought by implementing three metal-oxide surge arresters and an overhead ground wire. The purpose of these arresters is determined by their location in the circuit and the points that are vulnerable to adverse lightning effects: an arrester is installed to protect insulators between overhead lines and the supporting metallic mast, an arrester is installed to protect the point of contact between a stationary power supply wire and the train, and an arrester is installed to protect apparatus associated with the running tracks (return rail). An isolated earthing system is explored, and the effects of surge impedances and footing resistances are discussed. The voltage dropped across relevant vulnerable components and energy absorbed by the system components are determined by the simulation software Simulink. These results are compared with a railway system outfitted with the designed lightning protection mechanisms. Lightning currents are injected into the system using Heidler function where the parameters are in compliance with lightning protection standards. It is observed that the protection mechanisms defend susceptible components to a specified level. This demonstrates the success of the design in accordance with arrester protection levels (73.3 kV) and equipment withstand capabilities (a basic insulation level of 143 kV). This offers a protection margin of 95%. The largest percentage overshoot in the system is 39%, and this value is substantiated using reflection phenomena.

Kata kunci

Jaringan kolaborasi para penulis

7 penulis · 16 tautan kepenulisan bersama · 6 lintas organisasi

Arahkan kursor atau ketuk sebuah nama untuk menyorot rekan penulisnya. Klik dua kali untuk membuka halaman penulis.

  • Universiti Putra Malaysia
  • University of the Witwatersrand
  • Universiti Tenaga Nasional
  • Organisasi berbeda
  • Organisasi sama
  • Afiliasi tidak diketahui
  • Garis lebih tebal = lebih banyak artikel bersama · lingkaran lebih besar = lebih banyak artikel
Tampilkan sebagai tabel
Rekan penulisOrganisasiArtikel bersama
Miszaina OsmanUniversiti Tenaga Nasional1
Jasronita JasniUniversiti Putra Malaysia1
Sani Dahiru BubaUniversiti Putra Malaysia1
W. F. Wan AhmadUniversiti Putra Malaysia1
Mohammed Zainal Abidin Ab KadirUniversiti Putra Malaysia1

Afiliasi berasal dari OpenAlex; metadata OAI-PMH jurnal tidak memuatnya. Penulis tanpa ID OpenAlex dicocokkan berdasarkan nama, sehingga dua orang bisa tergabung atau satu orang bisa terpisah.

Sumber metadata: OAI-PMH (metadata jurnal) http://section.iaesonline.com/index.php/IJEEI/oai, pertama di-harvest 8 Nov 2026, terakhir terlihat 8 Nov 2026.
Metadata asli (oai_dc)
<oai_dc:dc xmlns="http://www.openarchives.org/OAI/2.0/" xmlns:dc="http://purl.org/dc/elements/1.1/" xmlns:oai_dc="http://www.openarchives.org/OAI/2.0/oai_dc/" xmlns:xsi="http://www.w3.org/2001/XMLSchema-instance" xsi:schemaLocation="http://www.openarchives.org/OAI/2.0/oai_dc/  http://www.openarchives.org/OAI/2.0/oai_dc.xsd">
	<dc:title xml:lang="en">Design of a Lightning Protection System for an Overhead 3 kV DC Electrified Railway Line: A Case Study from South Africa</dc:title>
	<dc:creator xml:lang="en">Radhalal, Kelishia</dc:creator>
	<dc:creator xml:lang="en">Gomes, Chandima</dc:creator>
	<dc:subject xml:lang="en">electrical</dc:subject>
	<dc:subject xml:lang="en">lightning</dc:subject>
	<dc:subject xml:lang="en">protection</dc:subject>
	<dc:subject xml:lang="en">railway</dc:subject>
	<dc:subject xml:lang="en">surge</dc:subject>
	<dc:description xml:lang="en">A protection scheme is proposed for the 3 kV DC railway, in Kwa-Zulu Natal province, a region with a high lightning occurrence density. The surge protection was sought by implementing three metal-oxide surge arresters and an overhead ground wire. The purpose of these arresters is determined by their location in the circuit and the points that are vulnerable to adverse lightning effects: an arrester is installed to protect insulators between overhead lines and the supporting metallic mast, an arrester is installed to protect the point of contact between a stationary power supply wire and the train, and an arrester is installed to protect apparatus associated with the running tracks (return rail). An isolated earthing system is explored, and the effects of surge impedances and footing resistances are discussed. The voltage dropped across relevant vulnerable components and energy absorbed by the system components are determined by the simulation software Simulink. These results are compared with a railway system outfitted with the designed lightning protection mechanisms. Lightning currents are injected into the system using Heidler function where the parameters are in compliance with lightning protection standards. It is observed that the protection mechanisms defend susceptible components to a specified level. This demonstrates the success of the design in accordance with arrester protection levels (73.3 kV) and equipment withstand capabilities (a basic insulation level of 143 kV). This offers a protection margin of 95%. The largest percentage overshoot in the system is 39%, and this value is substantiated using reflection phenomena.</dc:description>
	<dc:publisher xml:lang="en">IAES Indonesian Section</dc:publisher>
	<dc:date>2021-06-10</dc:date>
	<dc:type>info:eu-repo/semantics/article</dc:type>
	<dc:type>info:eu-repo/semantics/publishedVersion</dc:type>
	<dc:format>application/pdf</dc:format>
	<dc:identifier>https://section.iaesonline.com/index.php/IJEEI/article/view/2935</dc:identifier>
	<dc:identifier>10.52549/ijeei.v9i2.2935</dc:identifier>
	<dc:source xml:lang="en">Indonesian Journal of Electrical Engineering and Informatics (IJEEI); Vol. 9 No. 2: June 2021; 346-359</dc:source>
	<dc:source>2089-3272</dc:source>
	<dc:source>2089-3272</dc:source>
	<dc:language>en</dc:language>
	<dc:relation>https://section.iaesonline.com/index.php/IJEEI/article/view/2935/615</dc:relation>
</oai_dc:dc>