Jurnal
SINTA 1
Selfish Herd Optimisation based fractional order cascaded controllers for AGC study
Indonesian Journal of Electical Engineering and Informatics (IJEEI) · Vol. 9 No. 3 (2021) · hlm. 615–632
ISSN 2089-3272, 2089-3272
Terbit 2021-09-20
Penerbit IAES Indonesian Section
Bahasa en
Abstrak
In a modern, and complex power system (PS), robust controller is obligatory to regulate the frequency under uncertain load/parameter change of the system. In addition to this, presence of nonlinearities, load frequency control (LFC) of a Power System becomes more challenging which necessitates a suitable, and robust controller. Single stage controller does not perform immensely against aforesaid changed conditions. So, a novel non-integer/fractional order (FO) based two-stage controller incorporated with 2-degrees of freedom (2-DOF), derivative filter (N), named as 2-DOF-FOPIDN-FOPDN controller, is adopted to improve the dynamic performance of a 3-area power system. Each area of the power system consists of both non-renewable and renewable generating units. Again, to support the superior performance of 2-DOF-FOPIDN-FOPDN controller, it is compared with the result produced by PID, FOPID, and 2-DOF-PIDN-PDN controllers. The optimal design of these controllers is done by applying Selfish Herd Optimisation (SHO) technique. Further, the robustness of the 2-DOF-FOPIDN-FOPDN controller is authenticated by evaluating the system performance under parameter variation. The work is further extended to prove the supremacy of SHO algorithm over a recently published article based on pathfinder algorithm (PFA).
Jaringan kolaborasi para penulis
9 penulis ·
19 tautan kepenulisan bersama
· 10 lintas organisasi
Arahkan kursor atau ketuk sebuah nama untuk menyorot rekan penulisnya. Klik dua kali untuk membuka halaman penulis.
Siksha O Anusandhan University International Institute of Information Technology KIIT University Woosong University
Organisasi berbeda
Organisasi sama
Afiliasi tidak diketahui
Garis lebih tebal = lebih banyak artikel bersama · lingkaran lebih besar = lebih banyak artikel
Tampilkan sebagai tabel
Afiliasi berasal dari OpenAlex; metadata OAI-PMH jurnal tidak memuatnya. Penulis tanpa ID OpenAlex dicocokkan berdasarkan nama, sehingga dua orang bisa tergabung atau satu orang bisa terpisah.
Sumber metadata: OAI-PMH (metadata jurnal) http://section.iaesonline.com/index.php/IJEEI/oai, pertama di-harvest 8 Nov 2026, terakhir terlihat 8 Nov 2026.
Metadata asli (oai_dc)
<oai_dc:dc xmlns="http://www.openarchives.org/OAI/2.0/" xmlns:dc="http://purl.org/dc/elements/1.1/" xmlns:oai_dc="http://www.openarchives.org/OAI/2.0/oai_dc/" xmlns:xsi="http://www.w3.org/2001/XMLSchema-instance" xsi:schemaLocation="http://www.openarchives.org/OAI/2.0/oai_dc/ http://www.openarchives.org/OAI/2.0/oai_dc.xsd">
<dc:title xml:lang="en">Selfish Herd Optimisation based fractional order cascaded controllers for AGC study</dc:title>
<dc:creator xml:lang="en">Sahoo, Subhadra</dc:creator>
<dc:creator xml:lang="en">Jena, Narendra Kumar</dc:creator>
<dc:creator xml:lang="en">Sahu, Binod Kumar</dc:creator>
<dc:creator xml:lang="en">Ray, Prakash Kumar</dc:creator>
<dc:subject xml:lang="en">Automatic Generation Control</dc:subject>
<dc:subject xml:lang="en">Two-Degrees-Of Freedom</dc:subject>
<dc:subject xml:lang="en">Two-stage controller</dc:subject>
<dc:subject xml:lang="en">Non-integer Controller</dc:subject>
<dc:subject xml:lang="en">Selfish Herd Optimization.</dc:subject>
<dc:description xml:lang="en">In a modern, and complex power system (PS), robust controller is obligatory to regulate the frequency under uncertain load/parameter change of the system. In addition to this, presence of nonlinearities, load frequency control (LFC) of a Power System becomes more challenging which necessitates a suitable, and robust controller. Single stage controller does not perform immensely against aforesaid changed conditions. So, a novel non-integer/fractional order (FO) based two-stage controller incorporated with 2-degrees of freedom (2-DOF), derivative filter (N), named as 2-DOF-FOPIDN-FOPDN controller, is adopted to improve the dynamic performance of a 3-area power system. Each area of the power system consists of both non-renewable and renewable generating units. Again, to support the superior performance of 2-DOF-FOPIDN-FOPDN controller, it is compared with the result produced by PID, FOPID, and 2-DOF-PIDN-PDN controllers. The optimal design of these controllers is done by applying Selfish Herd Optimisation (SHO) technique. Further, the robustness of the 2-DOF-FOPIDN-FOPDN controller is authenticated by evaluating the system performance under parameter variation. The work is further extended to prove the supremacy of SHO algorithm over a recently published article based on pathfinder algorithm (PFA).</dc:description>
<dc:publisher xml:lang="en">IAES Indonesian Section</dc:publisher>
<dc:date>2021-09-20</dc:date>
<dc:type>info:eu-repo/semantics/article</dc:type>
<dc:type>info:eu-repo/semantics/publishedVersion</dc:type>
<dc:format>application/pdf</dc:format>
<dc:identifier>https://section.iaesonline.com/index.php/IJEEI/article/view/3009</dc:identifier>
<dc:identifier>10.52549/.v9i3.3009</dc:identifier>
<dc:source xml:lang="en">Indonesian Journal of Electrical Engineering and Informatics (IJEEI); Vol. 9 No. 3: September 2021; 615-632</dc:source>
<dc:source>2089-3272</dc:source>
<dc:source>2089-3272</dc:source>
<dc:language>en</dc:language>
<dc:relation>https://section.iaesonline.com/index.php/IJEEI/article/view/3009/634</dc:relation>
</oai_dc:dc>
Sitasi dan pengindeksan
Jumlah menurut tiap indeks pada 13 Nov 2026; setiap indeks menghitung sitasi dengan cara berbeda.
OpenAlex juga mencatat karya ini di: crossref.
Sitasi artikel ini
APA 7
Sahoo, S., Jena, N. K., Sahu, B. K., & Ray, P. K. (2021). Selfish Herd Optimisation based fractional order cascaded controllers for AGC study. Indonesian Journal of Electical Engineering and Informatics (IJEEI), 9(3), 615–632. https://doi.org/10.52549/.v9i3.3009
Salin
IEEE
S. Sahoo, N. K. Jena, B. K. Sahu, and P. K. Ray, “Selfish Herd Optimisation based fractional order cascaded controllers for AGC study,” Indonesian Journal of Electical Engineering and Informatics (IJEEI), vol. 9, no. 3, pp. 615–632, 2021, doi: 10.52549/.v9i3.3009.
Salin
Dibuat dari metadata jurnal; periksa nama penulis sebelum dipakai.