Distributed generation is playing an important role in power system to meet the increased load demand. Integration of Distributed Generator (DG) to grid leads to various issues of protection and control of power system structure. The effect of the distributed generators to the grid is changes the fault current level, which makes the fault analysis more complex. From the different fault issues occurs in a distributed generator integrated power system, classification of fault remains as one of the most vital issue even after years of in-depth research. This paper emphasis on the classification of faults in DG penetrated power system using Artificial Neural Network (ANN). Because researchers are attempting to detect and diagnose these faults as soon as possible in order to avoid financial losses, this work aims to investigate the sort of fault that happened in the hybrid system. This paper proposed artificial neural network based approaches for fault disturbances in a microgrid made up of wind turbine generators, fuel cells, and diesel generator. The voltage signal is retrieved at the point of common coupling (PCC). The extracted data are used for training and testing purpose. Artificial neural network technique is utilized for the classification of fault in the simulated model. Furthermore, performance indices (PIs) such as standard deviation and skewness are calculated for reduction of data size and better accuracy. Both the fault and parameters are varied to check the usefulness of the proposed method. Finally, the results are discussed and compared with different DG penetration.

Kata kunci

Jaringan kolaborasi para penulis

5 penulis · 6 tautan kepenulisan bersama

Arahkan kursor atau ketuk sebuah nama untuk menyorot rekan penulisnya. Klik dua kali untuk membuka halaman penulis.

  • Siksha O Anusandhan University
  • Organisasi berbeda
  • Organisasi sama
  • Afiliasi tidak diketahui
  • Garis lebih tebal = lebih banyak artikel bersama · lingkaran lebih besar = lebih banyak artikel
Tampilkan sebagai tabel
Rekan penulisOrganisasiArtikel bersama
Priya R. PattanaikSiksha O Anusandhan University1
Smaran Kumar SanyalSiksha O Anusandhan University1

Afiliasi berasal dari OpenAlex; metadata OAI-PMH jurnal tidak memuatnya. Penulis tanpa ID OpenAlex dicocokkan berdasarkan nama, sehingga dua orang bisa tergabung atau satu orang bisa terpisah.

Sumber metadata: OAI-PMH (metadata jurnal) http://section.iaesonline.com/index.php/IJEEI/oai, pertama di-harvest 8 Nov 2026, terakhir terlihat 8 Nov 2026.
Metadata asli (oai_dc)
<oai_dc:dc xmlns="http://www.openarchives.org/OAI/2.0/" xmlns:dc="http://purl.org/dc/elements/1.1/" xmlns:oai_dc="http://www.openarchives.org/OAI/2.0/oai_dc/" xmlns:xsi="http://www.w3.org/2001/XMLSchema-instance" xsi:schemaLocation="http://www.openarchives.org/OAI/2.0/oai_dc/  http://www.openarchives.org/OAI/2.0/oai_dc.xsd">
	<dc:title xml:lang="en">Fault Classification in a DG Connected Power System using Artificial Neural Network</dc:title>
	<dc:creator xml:lang="en">Bhuyan, Anshuman</dc:creator>
	<dc:creator xml:lang="en">Panigrahi, Basanta K.</dc:creator>
	<dc:creator xml:lang="en">Pati, Subhendu</dc:creator>
	<dc:subject xml:lang="en">Distributed Generators (DG)</dc:subject>
	<dc:subject xml:lang="en">Artificial Neural Network (ANN)</dc:subject>
	<dc:subject xml:lang="en">Point of Common Coupling (PCC)</dc:subject>
	<dc:description xml:lang="en">Distributed generation is playing an important role in power system to meet the increased load demand. Integration of Distributed Generator (DG) to grid leads to various issues of   protection and control of power system structure.  The effect of the distributed generators to the grid is changes the fault current level, which makes the fault analysis more complex. From the different fault issues occurs in a distributed generator integrated power system, classification of fault remains as one of the most vital issue even after years of in-depth research. This paper emphasis on the classification of faults in DG penetrated power system using Artificial Neural Network (ANN). Because researchers are attempting to detect and diagnose these faults as soon as possible in order to avoid financial losses, this work aims to investigate the sort of fault that happened in the hybrid system. This paper proposed artificial neural network based approaches for fault disturbances in a microgrid made up of wind turbine generators, fuel cells, and diesel generator. The voltage signal is retrieved at the point of common coupling (PCC). The extracted data are used for training and testing purpose.  Artificial neural network technique is utilized for the classification of fault in the simulated model. Furthermore, performance indices (PIs) such as standard deviation and skewness are calculated for reduction of data size and better accuracy. Both the fault and parameters are varied to check the usefulness of the proposed method. Finally, the results are discussed and compared with different DG penetration.</dc:description>
	<dc:publisher xml:lang="en">IAES Indonesian Section</dc:publisher>
	<dc:date>2022-06-25</dc:date>
	<dc:type>info:eu-repo/semantics/article</dc:type>
	<dc:type>info:eu-repo/semantics/publishedVersion</dc:type>
	<dc:format>application/pdf</dc:format>
	<dc:identifier>https://section.iaesonline.com/index.php/IJEEI/article/view/3777</dc:identifier>
	<dc:identifier>10.52549/ijeei.v10i2.3777</dc:identifier>
	<dc:source xml:lang="en">Indonesian Journal of Electrical Engineering and Informatics (IJEEI); Vol. 10 No. 2: June 2022; 498-507</dc:source>
	<dc:source>2089-3272</dc:source>
	<dc:source>2089-3272</dc:source>
	<dc:language>en</dc:language>
	<dc:relation>https://section.iaesonline.com/index.php/IJEEI/article/view/3777/709</dc:relation>
</oai_dc:dc>