Melola Discovery

← Melola Discovery

Jurnal SINTA 1

Pectoral Muscle Removal in Digital Mammograms Using Region Based Standard Otsu Technique

Indonesian Journal of Electical Engineering and Informatics (IJEEI) · Vol. 11 No. 2 (2023) · hlm. 337–348

DOI
10.52549/ijeei.v11i2.4043
ISSN
2089-3272, 2089-3272
Terbit
2023-05-20
Penerbit
IAES Indonesian Section
Bahasa
en

Abstrak

Mammography is usually the first preference of imaging diagnostic modalities used for detection of breast cancer in the early stage. Two projections Cranio Caudal (CC) and Medio-Lateral Oblique (MLO) which depict different degrees for visualizing the breast are used during digital mammogram acquisition and the MLO view shows more breast tissue and Pectoral Muscle (PM) area when compared to CC view. Although, the PM is a criterion used to show proper positioning, it can result in biased results of mammographic analysis like: cancer detection and breast tissue density estimation, because the PM area has similar or even higher intensity than breast tissue and breast lesions if present. This paper proposed a Region Based Standard Otsu thresholding method for the elimination of PM area present in MLO mammograms. The proposed algorithm was implemented using 322 digital mammograms from the Mammographic Image Analysis Society (MIAS) database, and the difference between the PM detected and the manually drawn PM region by an expert was evaluated. The results showed an average: Jaccard Similarity Index, False Positive Rate (FPR) and False Negative Rate (FNR) of 93.2%, 3.54% and 5.68% respectively and also an acceptable rate of 95.65%

Kata kunci

Jaringan kolaborasi para penulis

25 penulis · 88 tautan kepenulisan bersama · 29 lintas organisasi

Arahkan kursor atau ketuk sebuah nama untuk menyorot rekan penulisnya. Klik dua kali untuk membuka halaman penulis.

  • University of Nigeria
  • Scientific Equipment Development Institute, Enugu
  • Enugu State University of Science and Technology
  • Afe Babalola University
  • Injibara University
  • Central University of Technology
  • Babcock University
  • Organisasi berbeda
  • Organisasi sama
  • Afiliasi tidak diketahui
  • Garis lebih tebal = lebih banyak artikel bersama · lingkaran lebih besar = lebih banyak artikel
Tampilkan sebagai tabel
Rekan penulisOrganisasiArtikel bersama
Henry N. UzoScientific Equipment Development Institute, Enugu5
Ogbonna Ukachukwu OparakuUniversity of Nigeria5
C. C. UdezeUniversity of Nigeria4
Helen U. NonyeluScientific Equipment Development Institute, Enugu4
Tsehay Admassu AssegieInjibara University3
Ayodeji Olalekan SalauAfe Babalola University3
Elisha Didam MarkusCentral University of Technology2
Dickson E OnuUniversity of Nigeria1
Michael Okechukwu EzeaUniversity of Nigeria1
Henry O. OsuagwuUniversity of Nigeria1
Udora Nwabuoku NwaweluUniversity of Nigeria1
Adedeji Tomide AkindadeloBabcock University1
Ogechukwu Kingsley UgwuezeUniversity of Nigeria1
C. V. ChijinduUniversity of Nigeria1
A. M. AhanekuUniversity of Nigeria1
N. J. EnehUniversity of Nigeria1
Obinna M. EzejaUniversity of Nigeria1

Afiliasi berasal dari OpenAlex; metadata OAI-PMH jurnal tidak memuatnya. Penulis tanpa ID OpenAlex dicocokkan berdasarkan nama, sehingga dua orang bisa tergabung atau satu orang bisa terpisah.

Sumber metadata: OAI-PMH (metadata jurnal) http://section.iaesonline.com/index.php/IJEEI/oai, pertama di-harvest 8 Nov 2026, terakhir terlihat 8 Nov 2026.
Metadata asli (oai_dc)
<oai_dc:dc xmlns="http://www.openarchives.org/OAI/2.0/" xmlns:dc="http://purl.org/dc/elements/1.1/" xmlns:oai_dc="http://www.openarchives.org/OAI/2.0/oai_dc/" xmlns:xsi="http://www.w3.org/2001/XMLSchema-instance" xsi:schemaLocation="http://www.openarchives.org/OAI/2.0/oai_dc/  http://www.openarchives.org/OAI/2.0/oai_dc.xsd">
	<dc:title xml:lang="en">Pectoral Muscle Removal in Digital Mammograms Using Region Based Standard Otsu Technique</dc:title>
	<dc:creator xml:lang="en">Anusionwu, Jacinta C.</dc:creator>
	<dc:creator xml:lang="en">Chijindu, Vincent C.</dc:creator>
	<dc:creator xml:lang="en">Eneh, Joy N.</dc:creator>
	<dc:creator xml:lang="en">Ozue, ThankGod I.</dc:creator>
	<dc:creator xml:lang="en">Ezukwoke, Nnabuike</dc:creator>
	<dc:creator xml:lang="en">Ahaneku, Mamilus A.</dc:creator>
	<dc:creator xml:lang="en">Anoliefo, Edward C.</dc:creator>
	<dc:creator xml:lang="en">Ohagwu, Walter A.</dc:creator>
	<dc:subject xml:lang="en">Digital Mammogram</dc:subject>
	<dc:subject xml:lang="en">Medio-Lateral Oblique</dc:subject>
	<dc:subject xml:lang="en">Pectoral Muscle</dc:subject>
	<dc:subject xml:lang="en">Standard Otsu thresholding</dc:subject>
	<dc:subject xml:lang="en">Jaccard Similarity Index</dc:subject>
	<dc:subject xml:lang="en">False Negative Rate</dc:subject>
	<dc:subject xml:lang="en">False Positive Rate</dc:subject>
	<dc:description xml:lang="en">Mammography is usually the first preference of imaging diagnostic modalities used for detection of breast cancer in the early stage. Two projections Cranio Caudal (CC) and Medio-Lateral Oblique (MLO) which depict different degrees for visualizing the breast are used during digital mammogram acquisition and the MLO view shows more breast tissue and Pectoral Muscle (PM) area when compared to CC view. Although, the PM is a criterion used to show proper positioning, it can result in biased results of mammographic analysis like: cancer detection and breast tissue density estimation, because the PM area has similar or even higher intensity than breast tissue and breast lesions if present. This paper proposed a Region Based Standard Otsu thresholding method for the elimination of PM area present in MLO mammograms. The proposed algorithm was implemented using 322 digital mammograms from the Mammographic Image Analysis Society (MIAS) database, and the difference between the PM detected and the manually drawn PM region by an expert was evaluated. The results showed an average: Jaccard Similarity Index, False Positive Rate (FPR) and False Negative Rate (FNR) of 93.2%, 3.54% and 5.68% respectively and also an acceptable rate of 95.65%</dc:description>
	<dc:publisher xml:lang="en">IAES Indonesian Section</dc:publisher>
	<dc:date>2023-05-20</dc:date>
	<dc:type>info:eu-repo/semantics/article</dc:type>
	<dc:type>info:eu-repo/semantics/publishedVersion</dc:type>
	<dc:format>application/pdf</dc:format>
	<dc:identifier>https://section.iaesonline.com/index.php/IJEEI/article/view/4043</dc:identifier>
	<dc:identifier>10.52549/ijeei.v11i2.4043</dc:identifier>
	<dc:source xml:lang="en">Indonesian Journal of Electrical Engineering and Informatics (IJEEI); Vol. 11 No. 2: June 2023; 337-348</dc:source>
	<dc:source>2089-3272</dc:source>
	<dc:source>2089-3272</dc:source>
	<dc:language>en</dc:language>
	<dc:relation>https://section.iaesonline.com/index.php/IJEEI/article/view/4043/826</dc:relation>
</oai_dc:dc>