Melola Discovery

← Melola Discovery

Jurnal SINTA 1

Reduction of Emission Cost, Loss Cost and Energy Purchase Cost for Distribution Systems With Capacitors, Photovoltaic Distributed Generators, and Harmonics

Indonesian Journal of Electical Engineering and Informatics (IJEEI) · Vol. 11 No. 1 (2023) · hlm. 36–49

DOI
10.52549/ijeei.v11i1.4103
ISSN
2089-3272, 2089-3272
Terbit
2023-02-28
Penerbit
IAES Indonesian Section
Bahasa
en

Abstrak

In this paper, a bonobo optimizer (BO) and two other methods, particle swarm optimization (PSO) and salp swarm algorithm (SSA), are implemented to determine the location and sizing of photovoltaic distributed generators (PDGs) and capacitors in IEEE 69-bus radial distribution system with many nonlinear loads. The objective of the study is to minimize the costs for purchasing energy from main grid for load demand and power loss on transmission lines as well as cost for emission fines from fossil fuel generation units of the grid under considering strict constraints on penetration, voltage, current and harmonic distortions. The results have shown that BO is the best and most stable method in solving the considered optimization problem. With the use of the optimal solution from BO, the total cost is significantly reduced up to 80.52%. As compared to base system without capacitors and PDGs, the obtained solution can reduce power loss up to 94.48% and increase the voltage profile from the range of [0.9092 1.00] pu to higher range of [0.9907 1.0084] pu. In addition, total harmonic distortion (THD) and individual harmonic distortion (IHD) are also much improved and satisfied under the IEEE Std. 519. Thus, BO is a suitable method for the application of installing capacitors and PDGs in distribution systems.

Kata kunci

Jaringan kolaborasi para penulis

28 penulis · 70 tautan kepenulisan bersama · 48 lintas organisasi

Arahkan kursor atau ketuk sebuah nama untuk menyorot rekan penulisnya. Klik dua kali untuk membuka halaman penulis.

  • Ton Duc Thang University
  • Ho Chi Minh City University of Technology
  • Ho Chi Minh City University of Technology and Engineering
  • Industrial University of Ho Chi Minh City
  • Saigon University
  • VSB - Technical University of Ostrava
  • Van Lang University
  • Organisasi lain
  • Afiliasi tidak diketahui
  • Organisasi berbeda
  • Organisasi sama
  • Afiliasi tidak diketahui
  • Garis lebih tebal = lebih banyak artikel bersama · lingkaran lebih besar = lebih banyak artikel
Tampilkan sebagai tabel
Rekan penulisOrganisasiArtikel bersama
Thuan Thanh NguyenIndustrial University of Ho Chi Minh City7
Van-Duc PhanVan Lang University7
Bach Hoang DinhTon Duc Thang University6
Thanh Long DuongIndustrial University of Ho Chi Minh City4
Ly Huu PhamTon Duc Thang University4
Phan Nguyen VinhUniversity of Theatre and Cinema Ho Chi Minh City4
Phu Trieu HaSaigon University3
Tran Trong DaoTon Duc Thang University3
Tan Minh PhanTon Duc Thang University2
Chiem Trong HienHo Chi Minh City University of Industry and Trade2
Thanh Pham VanVSB - Technical University of Ostrava1
Václav SnåšelVSB - Technical University of Ostrava1
Chi Trung TruongAfiliasi tidak diketahui1
Quoc Trung NguyenAfiliasi tidak diketahui1
Minh‐Duc PhamHo Chi Minh City University of Technology1
Hong Phuc LamHo Chi Minh City University of Technology1
Khoa Hoang TruongHo Chi Minh City University of Technology1
Nhuan An LeHo Chi Minh City University of Technology1
Le Chi KienHo Chi Minh City University of Technology and Engineering1
Nguyễn Duy PhươngSaigon University1
Bao Quoc NguyenTon Duc Thang University1
Ngoc Au NguyenHo Chi Minh City University of Technology and Engineering1
Trieu Ton NgocHo Chi Minh City University of Technology and Engineering1
Thanh-Phuc NguyenIndustrial University of Ho Chi Minh City1
Trung Dung NguyenIndustrial University of Ho Chi Minh City1

Afiliasi berasal dari OpenAlex; metadata OAI-PMH jurnal tidak memuatnya. Penulis tanpa ID OpenAlex dicocokkan berdasarkan nama, sehingga dua orang bisa tergabung atau satu orang bisa terpisah.

Sumber metadata: OAI-PMH (metadata jurnal) http://section.iaesonline.com/index.php/IJEEI/oai, pertama di-harvest 8 Nov 2026, terakhir terlihat 8 Nov 2026.
Metadata asli (oai_dc)
<oai_dc:dc xmlns="http://www.openarchives.org/OAI/2.0/" xmlns:dc="http://purl.org/dc/elements/1.1/" xmlns:oai_dc="http://www.openarchives.org/OAI/2.0/oai_dc/" xmlns:xsi="http://www.w3.org/2001/XMLSchema-instance" xsi:schemaLocation="http://www.openarchives.org/OAI/2.0/oai_dc/  http://www.openarchives.org/OAI/2.0/oai_dc.xsd">
	<dc:title xml:lang="en">Reduction of Emission Cost, Loss Cost and Energy Purchase Cost for Distribution Systems With Capacitors, Photovoltaic Distributed Generators, and Harmonics</dc:title>
	<dc:creator xml:lang="en">Pham, Thai Dinh</dc:creator>
	<dc:creator xml:lang="en">Nguyen, Hung Duc</dc:creator>
	<dc:creator xml:lang="en">Nguyen, Thang Trung</dc:creator>
	<dc:subject xml:lang="en">Bonobo optimizer</dc:subject>
	<dc:subject xml:lang="en">Capacitor Emissions</dc:subject>
	<dc:subject xml:lang="en">Power loss</dc:subject>
	<dc:subject xml:lang="en">Harmonic</dc:subject>
	<dc:subject xml:lang="en">Voltage profile</dc:subject>
	<dc:description xml:lang="en">In this paper, a bonobo optimizer (BO) and two other methods, particle swarm optimization (PSO) and salp swarm algorithm (SSA), are implemented to determine the location and sizing of photovoltaic distributed generators (PDGs) and capacitors in IEEE 69-bus radial distribution system with many nonlinear loads. The objective of the study is to minimize the costs for purchasing energy from main grid for load demand and power loss on transmission lines as well as cost for emission fines from fossil fuel generation units of the grid under considering strict constraints on penetration, voltage, current and harmonic distortions. The results have shown that BO is the best and most stable method in solving the considered optimization problem. With the use of the optimal solution from BO, the total cost is significantly reduced up to 80.52%. As compared to base system without capacitors and PDGs, the obtained solution can reduce power loss up to 94.48% and increase the voltage profile from the range of [0.9092 1.00] pu to higher range of [0.9907 1.0084] pu. In addition, total harmonic distortion (THD) and individual harmonic distortion (IHD) are also much improved and satisfied under the IEEE Std. 519. Thus, BO is a suitable method for the application of installing capacitors and PDGs in distribution systems.</dc:description>
	<dc:publisher xml:lang="en">IAES Indonesian Section</dc:publisher>
	<dc:date>2023-02-28</dc:date>
	<dc:type>info:eu-repo/semantics/article</dc:type>
	<dc:type>info:eu-repo/semantics/publishedVersion</dc:type>
	<dc:format>application/pdf</dc:format>
	<dc:identifier>https://section.iaesonline.com/index.php/IJEEI/article/view/4103</dc:identifier>
	<dc:identifier>10.52549/ijeei.v11i1.4103</dc:identifier>
	<dc:source xml:lang="en">Indonesian Journal of Electrical Engineering and Informatics (IJEEI); Vol. 11 No. 1: March 2023; 36-49</dc:source>
	<dc:source>2089-3272</dc:source>
	<dc:source>2089-3272</dc:source>
	<dc:language>en</dc:language>
	<dc:relation>https://section.iaesonline.com/index.php/IJEEI/article/view/4103/804</dc:relation>
</oai_dc:dc>