Melola Discovery

← Melola Discovery

Jurnal SINTA 1

Performance Evaluation of Advanced PLL Techniques For Accurate FFPS Component Extraction

Indonesian Journal of Electical Engineering and Informatics (IJEEI) · Vol. 12 No. 3 (2024) · hlm. 667–689

DOI
10.52549/ijeei.v12i3.5686
ISSN
2089-3272, 2089-3272
Terbit
2024-09-27
Penerbit
IAES Indonesian Section
Bahasa
en

Abstrak

It is very necessary to adopt fundamental frequency positive sequence (FFPS) element extraction methods in order to maximise the efficiency of integrating and handling the use of renewable energy sources (RES). The decision to act in this manner is made with the purpose of contributing to the accomplishment of the aforementioned aim. The capability of the synchronous references frame phase-locked loop to reject variations over a broad variety of grid conditions is enhanced as a result of this. This is particularly true for voltage sags and surges that are accompanied by harmonics, irrespective of whether the harmonics are the result of balanced or unbalanced electrical current fluctuations. The accuracy of the extraction of FFPS components is significantly influenced by the frequency deviation in SRF-PLL systems. The frequency deviation is another critical component. This is a result of the frequency deviation not remaining constant. An investigation is being conducted to ascertain the effectiveness of a various advanced PLL techniques, such as the cascaded delayed signal cancellation (CDSC), the dual second-order generalized integrator (DSOGI) and the multiple delayed signal cancellation (MDSC). The objective of conducting this assessment is to facilitate the evaluation of the efficacy of these strategies, which is the reason for its implementation. The CDSC and MDSC PLL have been demonstrated to be preferable to other PLLs due to their ability to distinguish between even and odd harmonics. This is due to the fact that each of these harmonics possesses its own distinctive characteristics. This may be attributable to its capacity to independently identify either harmonic. The MATLAB simulation results is provided to demonstrate the exceptional performance of these highly advanced PLLs.

Kata kunci

Jaringan kolaborasi para penulis

3 penulis · 2 tautan kepenulisan bersama

Arahkan kursor atau ketuk sebuah nama untuk menyorot rekan penulisnya. Klik dua kali untuk membuka halaman penulis.

  • JSS Science and Technology University
  • Organisasi berbeda
  • Organisasi sama
  • Afiliasi tidak diketahui
  • Garis lebih tebal = lebih banyak artikel bersama · lingkaran lebih besar = lebih banyak artikel
Tampilkan sebagai tabel
Rekan penulisOrganisasiArtikel bersama
M. SarithaJSS Science and Technology University1

Afiliasi berasal dari OpenAlex; metadata OAI-PMH jurnal tidak memuatnya. Penulis tanpa ID OpenAlex dicocokkan berdasarkan nama, sehingga dua orang bisa tergabung atau satu orang bisa terpisah.

Sumber metadata: OAI-PMH (metadata jurnal) http://section.iaesonline.com/index.php/IJEEI/oai, pertama di-harvest 8 Nov 2026, terakhir terlihat 8 Nov 2026.
Metadata asli (oai_dc)
<oai_dc:dc xmlns="http://www.openarchives.org/OAI/2.0/" xmlns:dc="http://purl.org/dc/elements/1.1/" xmlns:oai_dc="http://www.openarchives.org/OAI/2.0/oai_dc/" xmlns:xsi="http://www.w3.org/2001/XMLSchema-instance" xsi:schemaLocation="http://www.openarchives.org/OAI/2.0/oai_dc/  http://www.openarchives.org/OAI/2.0/oai_dc.xsd">
	<dc:title xml:lang="en">Performance Evaluation of Advanced PLL Techniques For Accurate FFPS Component Extraction</dc:title>
	<dc:creator xml:lang="en">Saritha, M</dc:creator>
	<dc:creator xml:lang="en">Sidram, M H</dc:creator>
	<dc:subject xml:lang="en">Renewable energy sources</dc:subject>
	<dc:subject xml:lang="en">Phase-locked loop (PLL)</dc:subject>
	<dc:subject xml:lang="en">Multiple delayed signal cancellation PLL (MDSC-PLL)</dc:subject>
	<dc:subject xml:lang="en">Synchronous reference frame phase-locked loop (SRF-PLL)</dc:subject>
	<dc:subject xml:lang="en">Dual second order generalized integrator PLL (DSOGI-PLL) Cascaded delayed signal cancellation PLL</dc:subject>
	<dc:description xml:lang="en">It is very necessary to adopt fundamental frequency positive sequence (FFPS) element extraction methods in order to maximise the efficiency of integrating and handling the use of renewable energy sources (RES). The decision to act in this manner is made with the purpose of contributing to the accomplishment of the aforementioned aim. The capability of the synchronous references frame phase-locked loop to reject variations over a broad variety of grid conditions is enhanced as a result of this. This is particularly true for voltage sags and surges that are accompanied by harmonics, irrespective of whether the harmonics are the result of balanced or unbalanced electrical current fluctuations. The accuracy of the extraction of FFPS components is significantly influenced by the frequency deviation in SRF-PLL systems. The frequency deviation is another critical component. This is a result of the frequency deviation not remaining constant. An investigation is being conducted to ascertain the effectiveness of a various advanced PLL techniques, such as the cascaded delayed signal cancellation (CDSC), the dual second-order generalized integrator (DSOGI) and the multiple delayed signal cancellation (MDSC). The objective of conducting this assessment is to facilitate the evaluation of the efficacy of these strategies, which is the reason for its implementation. The CDSC and MDSC PLL have been demonstrated to be preferable to other PLLs due to their ability to distinguish between even and odd harmonics. This is due to the fact that each of these harmonics possesses its own distinctive characteristics. This may be attributable to its capacity to independently identify either harmonic. The MATLAB simulation results is provided to demonstrate the exceptional performance of these highly advanced PLLs.</dc:description>
	<dc:publisher xml:lang="en">IAES Indonesian Section</dc:publisher>
	<dc:date>2024-09-27</dc:date>
	<dc:type>info:eu-repo/semantics/article</dc:type>
	<dc:type>info:eu-repo/semantics/publishedVersion</dc:type>
	<dc:format>application/pdf</dc:format>
	<dc:identifier>https://section.iaesonline.com/index.php/IJEEI/article/view/5686</dc:identifier>
	<dc:identifier>10.52549/ijeei.v12i3.5686</dc:identifier>
	<dc:source xml:lang="en">Indonesian Journal of Electrical Engineering and Informatics (IJEEI); Vol. 12 No. 3: September 2024; 667-689</dc:source>
	<dc:source>2089-3272</dc:source>
	<dc:source>2089-3272</dc:source>
	<dc:language>en</dc:language>
	<dc:relation>https://section.iaesonline.com/index.php/IJEEI/article/view/5686/941</dc:relation>
</oai_dc:dc>