Melola Discovery

← Melola Discovery

Jurnal SINTA 1

Fractional Order Sliding Mode Control to Mitigate Power Quality Issues using Dynamic Voltage Restorer in Distribution Network

Indonesian Journal of Electical Engineering and Informatics (IJEEI) · Vol. 13 No. 2 (2025) · hlm. 324–335

DOI
10.52549/ijeei.v13i2.6031
ISSN
2089-3272, 2089-3272
Terbit
2025-04-25
Penerbit
IAES Indonesian Section
Bahasa
en

Abstrak

Power quality (PQ) issues lead industrial customers to suffer significant financial losses. These PQ issues are garnering more attention from electricity suppliers and consumers in the modern day. This study addresses prevalent PQ issues, namely voltage sag and swell, stemming from a decrease in RMS voltage within electrical networks, particularly impacting sensitive loads. The solution proposed involves employing a series connected custom power device (CPD) named as dynamic voltage restorer (DVR) with an integrated DC battery for energy storage, to consistently maintain the requisite voltage magnitude. To effectively combat voltage sag and swell, the study introduces a novel control strategy known as fractional order sliding mode control (FOSMC). Noteworthy features of the FOSMC methodology include its capacity to autonomously and dynamically address sag and swell issues. The Simscape toolbox of MATLAB®/Simulink® is used to perform simulations to showcase the efficacy of the FOSMC technique. The results demonstrate that this strategy ensures total harmonic distortion remains below 5% and achieves sag/swell mitigation in less than 2 milliseconds, aligning with SEMI-F-47 and IEEE voltage standard 1159-2019. In summary, the study introduces and validates a robust control strategy implemented in a DVR system to autonomously alleviate voltage sag and swell issues, with simulation results supporting its effectiveness in upholding PQ standards. The FOSMC scheme with DVR is also compared with FOSMC scheme with DSTATCOM as well as with super twisting sliding mode control (STSMC) algorithm and classical sliding mode controller (SMC) to show the effectiveness of the proposed scheme. The FOSMC technique with DVR is more effective in restoring voltage sag/swell and PQ issues.

Kata kunci

Jaringan kolaborasi para penulis

9 penulis · 22 tautan kepenulisan bersama · 12 lintas organisasi

Arahkan kursor atau ketuk sebuah nama untuk menyorot rekan penulisnya. Klik dua kali untuk membuka halaman penulis.

  • Effat University
  • University of Wah
  • University of Engineering and Technology Taxila
  • Nahda University
  • Afiliasi tidak diketahui
  • Organisasi berbeda
  • Organisasi sama
  • Afiliasi tidak diketahui
  • Garis lebih tebal = lebih banyak artikel bersama · lingkaran lebih besar = lebih banyak artikel
Tampilkan sebagai tabel
Rekan penulisOrganisasiArtikel bersama
Rabab Hamed M. AlyNahda University3
Rawan A RadaEffat University2
Aziza I. HusseinEffat University1

Afiliasi berasal dari OpenAlex; metadata OAI-PMH jurnal tidak memuatnya. Penulis tanpa ID OpenAlex dicocokkan berdasarkan nama, sehingga dua orang bisa tergabung atau satu orang bisa terpisah.

Sumber metadata: OAI-PMH (metadata jurnal) http://section.iaesonline.com/index.php/IJEEI/oai, pertama di-harvest 8 Nov 2026, terakhir terlihat 8 Nov 2026.
Metadata asli (oai_dc)
<oai_dc:dc xmlns="http://www.openarchives.org/OAI/2.0/" xmlns:dc="http://purl.org/dc/elements/1.1/" xmlns:oai_dc="http://www.openarchives.org/OAI/2.0/oai_dc/" xmlns:xsi="http://www.w3.org/2001/XMLSchema-instance" xsi:schemaLocation="http://www.openarchives.org/OAI/2.0/oai_dc/  http://www.openarchives.org/OAI/2.0/oai_dc.xsd">
	<dc:title xml:lang="en">Fractional Order Sliding Mode Control to Mitigate Power Quality Issues using Dynamic Voltage Restorer in Distribution Network</dc:title>
	<dc:creator xml:lang="en">Yaqub, Muhammad Haroon</dc:creator>
	<dc:creator xml:lang="en">Hanif, Aamir</dc:creator>
	<dc:creator xml:lang="en">Anwar, Naveed</dc:creator>
	<dc:creator xml:lang="en">Ullah, Mian Farhan</dc:creator>
	<dc:creator xml:lang="en">Shah, Muhammad Shahzaib</dc:creator>
	<dc:creator xml:lang="en">Hussein, Aziza I.</dc:creator>
	<dc:subject xml:lang="en">Power Quality Enhancement</dc:subject>
	<dc:subject xml:lang="en">Sliding Mode Control (SMC)</dc:subject>
	<dc:subject xml:lang="en">Fractional Order SMC</dc:subject>
	<dc:subject xml:lang="en">Dynamic Voltage Restorer</dc:subject>
	<dc:subject xml:lang="en">Voltage Sag/Swell</dc:subject>
	<dc:description xml:lang="en">Power quality (PQ) issues lead industrial customers to suffer significant financial losses. These PQ issues are garnering more attention from electricity suppliers and consumers in the modern day. This study addresses prevalent PQ issues, namely voltage sag and swell, stemming from a decrease in RMS voltage within electrical networks, particularly impacting sensitive loads. The solution proposed involves employing a series connected custom power device (CPD) named as dynamic voltage restorer (DVR) with an integrated DC battery for energy storage, to consistently maintain the requisite voltage magnitude. To effectively combat voltage sag and swell, the study introduces a novel control strategy known as fractional order sliding mode control (FOSMC). Noteworthy features of the FOSMC methodology include its capacity to autonomously and dynamically address sag and swell issues. The Simscape toolbox of MATLAB®/Simulink® is used to perform simulations to showcase the efficacy of the FOSMC technique. The results demonstrate that this strategy ensures total harmonic distortion remains below 5% and achieves sag/swell mitigation in less than 2 milliseconds, aligning with SEMI-F-47 and IEEE voltage standard 1159-2019. In summary, the study introduces and validates a robust control strategy implemented in a DVR system to autonomously alleviate voltage sag and swell issues, with simulation results supporting its effectiveness in upholding PQ standards. The FOSMC scheme with DVR is also compared with FOSMC scheme with DSTATCOM as well as with super twisting sliding mode control (STSMC) algorithm and classical sliding mode controller (SMC) to show the effectiveness of the proposed scheme. The FOSMC technique with DVR is more effective in restoring voltage sag/swell and PQ issues.</dc:description>
	<dc:publisher xml:lang="en">IAES Indonesian Section</dc:publisher>
	<dc:date>2025-04-25</dc:date>
	<dc:type>info:eu-repo/semantics/article</dc:type>
	<dc:type>info:eu-repo/semantics/publishedVersion</dc:type>
	<dc:format>application/pdf</dc:format>
	<dc:identifier>https://section.iaesonline.com/index.php/IJEEI/article/view/6031</dc:identifier>
	<dc:identifier>10.52549/ijeei.v13i2.6031</dc:identifier>
	<dc:source xml:lang="en">Indonesian Journal of Electrical Engineering and Informatics (IJEEI); Vol. 13 No. 2: June 2025; 324-335</dc:source>
	<dc:source>2089-3272</dc:source>
	<dc:source>2089-3272</dc:source>
	<dc:language>en</dc:language>
	<dc:relation>https://section.iaesonline.com/index.php/IJEEI/article/view/6031/998</dc:relation>
</oai_dc:dc>