Melola Discovery

← Melola Discovery

Jurnal SINTA 1

Quartz Crystal Microbalance (QCM) Sensor Array with Varying PMMA Coatings for Coffee Roasting Aroma Monitoring

Indonesian Journal of Electical Engineering and Informatics (IJEEI) · Vol. 14 No. 1 (2026) · hlm. 153–166

DOI
10.52549/ijeei.v14i1.7760
ISSN
2089-3272, 2089-3272
Terbit
2026-03-23
Penerbit
IAES Indonesian Section
Bahasa
en

Abstrak

This study investigates how polymethyl methacrylate (PMMA) coating concentration (3–15 wt%) tunes the response of an eight-channel Quartz Crystal Microbalance (QCM) sensor array to real coffee roasting volatiles at 200–240 °C. One channel was left uncoated as a reference, while seven channels were coated with different PMMA concentrations to introduce controlled response diversity. Baseline-corrected frequency shifts were processed into qualitative features describing response magnitude, kinetics, and early recovery, and principal component analysis (PCA) was used to visualize multichannel pattern structure across repeated roasts. Consistent temperature-dependent response patterns were observed, while run-to-run variability increased at higher temperatures. The first two principal components captured ~75% of the total variance (PC1 dominated by integrated response magnitude and PC2 reflecting kinetic variability). Because chamber humidity increased during roasting, a supplementary robustness check was performed using recorded RH; temperature-dependent structure remained after accounting for humidity effects. Overall, discrimination arises from the collective multichannel response, suggesting potential applicability of PMMA-coated QCM arrays for qualitative coffee roasting monitoring, pending further validation with larger datasets and complementary analytical methods.

Kata kunci

Jaringan kolaborasi para penulis

40 penulis · 96 tautan kepenulisan bersama · 24 lintas organisasi · menampilkan 40 yang paling banyak terhubung

Arahkan kursor atau ketuk sebuah nama untuk menyorot rekan penulisnya. Klik dua kali untuk membuka halaman penulis.

  • University of Brawijaya
  • Politeknik Negeri Batam
  • University of Miyazaki
  • UK Centre for Ecology & Hydrology
  • State University of Malang
  • Organisasi berbeda
  • Organisasi sama
  • Afiliasi tidak diketahui
  • Garis lebih tebal = lebih banyak artikel bersama · lingkaran lebih besar = lebih banyak artikel
Tampilkan sebagai tabel
Rekan penulisOrganisasiArtikel bersama
Zainul AbidinUniversity of Brawijaya3
Erni YudaningtyasUniversity of Brawijaya2
Muhammad Fauzan Edy PurnomoUniversity of Brawijaya2
Denda DewatamaUniversity of Brawijaya2
Sabriansyah Rizqika AkbarUniversity of Brawijaya1
Issa ArwaniUniversity of Brawijaya1
Wayan Firdaus MahmudyUniversity of Brawijaya1
Gayatri Dwi SantikaUniversity of Brawijaya1
Stefanus Dion FinnadiUniversity of Brawijaya1
Kakeru ArakiUniversity of Miyazaki1
Ryoichi MiyauchiUniversity of Miyazaki1
Nauval AryawiratamaUniversity of Brawijaya1
Adin Okta TriqadafiUniversity of Brawijaya1
Aldi Dwi PutraUniversity of Brawijaya1
Triswantoro PutroUniversity of Brawijaya1
Dewi AnggraeniUniversity of Brawijaya1
Ahmad Riyad FirdausPoliteknik Negeri Batam1
Imam SholihuddinUniversity of Brawijaya1
Fania Putri HutasoitPoliteknik Negeri Batam1
Ika Karlina Laila Nur SuciningtyasPoliteknik Negeri Batam1
M. Gilang RamadhanUniversity of Brawijaya1
Eka MaulanaUniversity of Brawijaya1
Heru NurwarsitoUniversity of Brawijaya1
Aji Prasetya WibawaState University of Malang1
Resnu Wahyu AdabyUniversity of Brawijaya1
Cahyo PrayogoUniversity of Brawijaya1
Didik SuprayogoUniversity of Brawijaya1
Simon OakleyUK Centre for Ecology & Hydrology1
Sholeh Hadi PramonoUniversity of Brawijaya1
Mahdin RohmatillahUniversity of Brawijaya1
Dwi Utari SuryaUniversity of Brawijaya1
Muhammad Aziz MuslimUniversity of Brawijaya1
Hermin SulistyartiUniversity of Brawijaya1
R SugiartoUniversity of Brawijaya1
Erwin SulistyoUniversity of Brawijaya1
Atikah AtikahUniversity of Brawijaya1

Afiliasi berasal dari OpenAlex; metadata OAI-PMH jurnal tidak memuatnya. Penulis tanpa ID OpenAlex dicocokkan berdasarkan nama, sehingga dua orang bisa tergabung atau satu orang bisa terpisah.

Sumber metadata: OAI-PMH (metadata jurnal) http://section.iaesonline.com/index.php/IJEEI/oai, pertama di-harvest 8 Nov 2026, terakhir terlihat 8 Nov 2026.
Metadata asli (oai_dc)
<oai_dc:dc xmlns="http://www.openarchives.org/OAI/2.0/" xmlns:dc="http://purl.org/dc/elements/1.1/" xmlns:oai_dc="http://www.openarchives.org/OAI/2.0/oai_dc/" xmlns:xsi="http://www.w3.org/2001/XMLSchema-instance" xsi:schemaLocation="http://www.openarchives.org/OAI/2.0/oai_dc/  http://www.openarchives.org/OAI/2.0/oai_dc.xsd">
	<dc:title xml:lang="en">Quartz Crystal Microbalance (QCM) Sensor Array with Varying PMMA Coatings for Coffee Roasting Aroma Monitoring</dc:title>
	<dc:creator xml:lang="en">Muttaqin, Adharul</dc:creator>
	<dc:creator xml:lang="en">Sakti, Setyawan Purnomo</dc:creator>
	<dc:creator xml:lang="en">Naba, Agus</dc:creator>
	<dc:creator xml:lang="en">Mudjirahardjo, Panca</dc:creator>
	<dc:subject xml:lang="en">Quartz Crystal Microbalance</dc:subject>
	<dc:subject xml:lang="en">Aroma Monitoring</dc:subject>
	<dc:subject xml:lang="en">PMMA Coating</dc:subject>
	<dc:subject xml:lang="en">Qualitative Monitoring</dc:subject>
	<dc:subject xml:lang="en">Sensor Array</dc:subject>
	<dc:description xml:lang="en">This study investigates how polymethyl methacrylate (PMMA) coating concentration (3–15 wt%) tunes the response of an eight-channel Quartz Crystal Microbalance (QCM) sensor array to real coffee roasting volatiles at 200–240 °C. One channel was left uncoated as a reference, while seven channels were coated with different PMMA concentrations to introduce controlled response diversity. Baseline-corrected frequency shifts were processed into qualitative features describing response magnitude, kinetics, and early recovery, and principal component analysis (PCA) was used to visualize multichannel pattern structure across repeated roasts. Consistent temperature-dependent response patterns were observed, while run-to-run variability increased at higher temperatures. The first two principal components captured ~75% of the total variance (PC1 dominated by integrated response magnitude and PC2 reflecting kinetic variability). Because chamber humidity increased during roasting, a supplementary robustness check was performed using recorded RH; temperature-dependent structure remained after accounting for humidity effects. Overall, discrimination arises from the collective multichannel response, suggesting potential applicability of PMMA-coated QCM arrays for qualitative coffee roasting monitoring, pending further validation with larger datasets and complementary analytical methods.</dc:description>
	<dc:publisher xml:lang="en">IAES Indonesian Section</dc:publisher>
	<dc:date>2026-03-23</dc:date>
	<dc:type>info:eu-repo/semantics/article</dc:type>
	<dc:type>info:eu-repo/semantics/publishedVersion</dc:type>
	<dc:format>application/pdf</dc:format>
	<dc:identifier>https://section.iaesonline.com/index.php/IJEEI/article/view/7760</dc:identifier>
	<dc:identifier>10.52549/ijeei.v14i1.7760</dc:identifier>
	<dc:source xml:lang="en">Indonesian Journal of Electrical Engineering and Informatics (IJEEI); Vol. 14 No. 1: March 2026; 153-166</dc:source>
	<dc:source>2089-3272</dc:source>
	<dc:source>2089-3272</dc:source>
	<dc:language>en</dc:language>
	<dc:relation>https://section.iaesonline.com/index.php/IJEEI/article/view/7760/1063</dc:relation>
</oai_dc:dc>