Melola Discovery

← Melola Discovery

Jurnal SINTA 1

A Critical Review of Fault Detection and Diagnosis in Crystalline Silicon Photovoltaic Systems: From Cell-Level Degradation to Array-Level Failures

Indonesian Journal of Electical Engineering and Informatics (IJEEI) · Vol. 14 No. 1 (2026) · hlm. 179–195

DOI
10.52549/ijeei.v14i1.7890
ISSN
2089-3272, 2089-3272
Terbit
2026-03-24
Penerbit
IAES Indonesian Section
Bahasa
en

Abstrak

The long-term reliability of photovoltaic (PV) systems depends on the timely detection and diagnosis of faults. Crystalline silicon (c-Si) technology dominates the global PV market, and is susceptible to a wide range of degradation modes. This review provides a structured analysis of these faults, categorizing them into material-level intrinsic defects, environmentally-induced extrinsic faults, and system-level interconnection faults. The review details the underlying mechanisms of key degradation modes, including Light- and Elevated Temperature-Induced Degradation (LeTID), Potential Induced Degradation (PID), and micro-crack propagation. A critical evaluation of corresponding Fault Detection and Diagnostic (FDD) methodologies follows. It encompasses laboratory-grade imaging techniques, field-deployable electrical analysis, and emerging data-driven approaches leveraging machine learning and unmanned aerial vehicles (UAVs). This synthesis reveals a fundamental trade-off between diagnostic resolution and operational scalability. To navigate this trade-off, the study analyzes the evolution towards integrated, tiered monitoring strategies and hybrid data-fusion techniques. Furthermore, the review identifies persistent research gaps, such as the need for explainable artificial intelligence (XAI), standardized datasets, robust transfer learning models, and cyber-secure FDD architectures. By bridging the fundamental science of cell degradation with the system-level engineering, this article serves as a roadmap for advancing predictive maintenance and ensuring the sustainability of large-scale PV infrastructure.

Kata kunci

Jaringan kolaborasi para penulis

30 penulis · 65 tautan kepenulisan bersama · 29 lintas organisasi

Arahkan kursor atau ketuk sebuah nama untuk menyorot rekan penulisnya. Klik dua kali untuk membuka halaman penulis.

  • Mohammed V University
  • Ecole Mohammadia d'Ingénieurs
  • Université Sultan Moulay Slimane
  • Centre National de la Recherche Scientifique
  • Université de Nouakchott
  • Sidi Mohamed Ben Abdellah University
  • Université Ibn-Tofail
  • Organisasi lain
  • Afiliasi tidak diketahui
  • Organisasi berbeda
  • Organisasi sama
  • Afiliasi tidak diketahui
  • Garis lebih tebal = lebih banyak artikel bersama · lingkaran lebih besar = lebih banyak artikel
Tampilkan sebagai tabel
Rekan penulisOrganisasiArtikel bersama
Mohamed AkherrazEcole Mohammadia d'Ingénieurs4
Youssef MajdoubMohammed V University4
Rachid El AkhrifMohammed V University3
Mohamed BararaCentre National de la Recherche Scientifique3
Abdel Kader MahmoudUniversité de Nouakchott3
Ethmane Isselem Arbih MahmoudMohammed V University3
Ali MousmiMohammed V University2
Yassine El HoumMohammed V University2
Anass BakouriMohammed V University2
Rachid TouilebMohammed V University2
Mohammed AkherrazAfiliasi tidak diketahui2
Né Dah EidaAfiliasi tidak diketahui1
Boujemaa HammaEcole Mohammadia d'Ingénieurs1
Badre BossoufiSidi Mohamed Ben Abdellah University1
Abderrahim BennassarAfiliasi tidak diketahui1
Mohamed Moustapha KetabAfiliasi tidak diketahui1
Rania MoutchouMohammed V University1
Hassane MahmoudiMohammed V University1
Zouhair SadouneUniversité Ibn-Tofail1
Chaymae LaoufiMohammed V University1
Ali NejmiUniversité Sultan Moulay Slimane1
Mouhssine LagraouiUniversité Sultan Moulay Slimane1
Mouna LhayaniMohammed V University1
Mohamed BenfarsUniversité Sultan Moulay Slimane1
Yassine ZahraouiHassania School of Public Works1
Sara ElbadaouiEcole Mohammadia d'Ingénieurs1
Farid OufqirUniversité Sultan Moulay Slimane1

Afiliasi berasal dari OpenAlex; metadata OAI-PMH jurnal tidak memuatnya. Penulis tanpa ID OpenAlex dicocokkan berdasarkan nama, sehingga dua orang bisa tergabung atau satu orang bisa terpisah.

Sumber metadata: OAI-PMH (metadata jurnal) http://section.iaesonline.com/index.php/IJEEI/oai, pertama di-harvest 8 Nov 2026, terakhir terlihat 8 Nov 2026.
Metadata asli (oai_dc)
<oai_dc:dc xmlns="http://www.openarchives.org/OAI/2.0/" xmlns:dc="http://purl.org/dc/elements/1.1/" xmlns:oai_dc="http://www.openarchives.org/OAI/2.0/oai_dc/" xmlns:xsi="http://www.w3.org/2001/XMLSchema-instance" xsi:schemaLocation="http://www.openarchives.org/OAI/2.0/oai_dc/  http://www.openarchives.org/OAI/2.0/oai_dc.xsd">
	<dc:title xml:lang="en">A Critical Review of Fault Detection and Diagnosis in Crystalline Silicon Photovoltaic Systems: From Cell-Level Degradation to Array-Level Failures</dc:title>
	<dc:creator xml:lang="en">Tebay, Imane</dc:creator>
	<dc:creator xml:lang="en">Abbou, Ahmed</dc:creator>
	<dc:creator xml:lang="en">Ait Talount, Hachem</dc:creator>
	<dc:subject xml:lang="en">Photovoltaic (PV) systems</dc:subject>
	<dc:subject xml:lang="en">Fault detection and Diagnosis (FDD)</dc:subject>
	<dc:subject xml:lang="en">Degradation mechanisms</dc:subject>
	<dc:subject xml:lang="en">Crystalline silicon</dc:subject>
	<dc:subject xml:lang="en">Infrared thermography</dc:subject>
	<dc:subject xml:lang="en">Electroluminescence</dc:subject>
	<dc:subject xml:lang="en">Machine learning</dc:subject>
	<dc:subject xml:lang="en">Predictive maintenance.</dc:subject>
	<dc:description xml:lang="en">The long-term reliability of photovoltaic (PV) systems depends on the timely detection and diagnosis of faults. Crystalline silicon (c-Si) technology dominates the global PV market, and is susceptible to a wide range of degradation modes. This review provides a structured analysis of these faults, categorizing them into material-level intrinsic defects, environmentally-induced extrinsic faults, and system-level interconnection faults. The review details the underlying mechanisms of key degradation modes, including Light- and Elevated Temperature-Induced Degradation (LeTID), Potential Induced Degradation (PID), and micro-crack propagation. A critical evaluation of corresponding Fault Detection and Diagnostic (FDD) methodologies follows. It encompasses laboratory-grade imaging techniques, field-deployable electrical analysis, and emerging data-driven approaches leveraging machine learning and unmanned aerial vehicles (UAVs). This synthesis reveals a fundamental trade-off between diagnostic resolution and operational scalability. To navigate this trade-off, the study analyzes the evolution towards integrated, tiered monitoring strategies and hybrid data-fusion techniques. Furthermore, the review identifies persistent research gaps, such as the need for explainable artificial intelligence (XAI), standardized datasets, robust transfer learning models, and cyber-secure FDD architectures. By bridging the fundamental science of cell degradation with the system-level engineering, this article serves as a roadmap for advancing predictive maintenance and ensuring the sustainability of large-scale PV infrastructure.</dc:description>
	<dc:publisher xml:lang="en">IAES Indonesian Section</dc:publisher>
	<dc:date>2026-03-24</dc:date>
	<dc:type>info:eu-repo/semantics/article</dc:type>
	<dc:type>info:eu-repo/semantics/publishedVersion</dc:type>
	<dc:format>application/pdf</dc:format>
	<dc:identifier>https://section.iaesonline.com/index.php/IJEEI/article/view/7890</dc:identifier>
	<dc:identifier>10.52549/ijeei.v14i1.7890</dc:identifier>
	<dc:source xml:lang="en">Indonesian Journal of Electrical Engineering and Informatics (IJEEI); Vol. 14 No. 1: March 2026; 179-195</dc:source>
	<dc:source>2089-3272</dc:source>
	<dc:source>2089-3272</dc:source>
	<dc:language>en</dc:language>
	<dc:relation>https://section.iaesonline.com/index.php/IJEEI/article/view/7890/1066</dc:relation>
</oai_dc:dc>