Akses terbuka
Jurnal
SINTA 1
Identification of the Main Water Quality Parameters for Monitoring and Evaluating Watershed Health
Indonesian Journal of Geography · Vol. 52 No. 2 (2020) · hlm. 227–238
ISSN 2354-9114, 0024-9521
Terbit 2020-09-02
Penerbit Faculty of Geography, Universitas Gadjah Mada
Bahasa eng
Abstrak
Water quality is one of the crucial parameters in monitoring and evaluating watersheds. A large number of parameters causes the monitoring and evaluation of watershed performance to be less efficient and costly. This study aims to determine the main parameters as a method of simplifying water quality observation parameters by producing equations that can be used to predict the level of pollution of a non-point source pollutant (watershed). A sampling of surface water was carried out by purposive sampling at several outlets located in the Brantas and Upper Solo watersheds. The research parameters analysed were: TSS, TDS, BOD, COD, Phenol, Free Chlorineine, Sulfide, Arsenic, Fe, Pb, Phosphate, Nitrate, Nitrite, Detergent, Turbidity and E. Coli. The results of the analysis of water quality are used to calculate the value of the Pollution Index (PI) according to the Decree of the Minister of Environment No. 115 of 2003 and to determine the class of water quality standards that refer to Class III water quality standards, in Government Regulation No.82 of 2001. The analysis showed that all samples were at mild to moderate pollution levels, and did not meet class III water quality standards. Multiple regression analysis produced two equations, namely: Model 1: PI = 3.952 + 91.668 Phenol and Model 2: PI = 3.086 + 80.167 Phenol + 0.152 BOD, with R squared values of 53% and 69.9% with a confidence level of 0.005. Thus the prediction of pollution levels of similar watershed can be made only by using the two most influential parameters namely phenol and/or BOD alone.
Jaringan kolaborasi para penulis
9 penulis ·
10 tautan kepenulisan bersama
· 2 lintas organisasi
Arahkan kursor atau ketuk sebuah nama untuk menyorot rekan penulisnya. Klik dua kali untuk membuka halaman penulis.
Watershed Ministry of Environment and Forestry, Republic of Indonesia National Research and Innovation Agency Afiliasi tidak diketahui
Organisasi berbeda
Organisasi sama
Afiliasi tidak diketahui
Garis lebih tebal = lebih banyak artikel bersama · lingkaran lebih besar = lebih banyak artikel
Tampilkan sebagai tabel
Afiliasi berasal dari OpenAlex; metadata OAI-PMH jurnal tidak memuatnya. Penulis tanpa ID OpenAlex dicocokkan berdasarkan nama, sehingga dua orang bisa tergabung atau satu orang bisa terpisah.
Sumber metadata: OAI-PMH (metadata jurnal) http://jurnal.ugm.ac.id/ijg/oai, pertama di-harvest 8 Nov 2026, terakhir terlihat 16 Nov 2026.
Metadata asli (oai_dc)
<oai_dc:dc xmlns="http://www.openarchives.org/OAI/2.0/" xmlns:dc="http://purl.org/dc/elements/1.1/" xmlns:oai_dc="http://www.openarchives.org/OAI/2.0/oai_dc/" xmlns:xsi="http://www.w3.org/2001/XMLSchema-instance" xsi:schemaLocation="http://www.openarchives.org/OAI/2.0/oai_dc/ http://www.openarchives.org/OAI/2.0/oai_dc.xsd">
<dc:title xml:lang="en-US">Identification of the Main Water Quality Parameters for Monitoring and Evaluating Watershed Health</dc:title>
<dc:creator>Susanti, Pranatasari Dyah</dc:creator>
<dc:creator>Wahyuningrum, Nining</dc:creator>
<dc:subject xml:lang="en-US">Hydrology</dc:subject>
<dc:subject xml:lang="en-US">water quality; dominant parameters; watershed</dc:subject>
<dc:subject xml:lang="en-US">Water Quality</dc:subject>
<dc:description xml:lang="en-US">Water quality is one of the crucial parameters in monitoring and evaluating watersheds. A large number of parameters causes the monitoring and evaluation of watershed performance to be less efficient and costly. This study aims to determine the main parameters as a method of simplifying water quality observation parameters by producing equations that can be used to predict the level of pollution of a non-point source pollutant (watershed). A sampling of surface water was carried out by purposive sampling at several outlets located in the Brantas and Upper Solo watersheds. The research parameters analysed were: TSS, TDS, BOD, COD, Phenol, Free Chlorineine, Sulfide, Arsenic, Fe, Pb, Phosphate, Nitrate, Nitrite, Detergent, Turbidity and E. Coli. The results of the analysis of water quality are used to calculate the value of the Pollution Index (PI) according to the Decree of the Minister of Environment No. 115 of 2003 and to determine the class of water quality standards that refer to Class III water quality standards, in Government Regulation No.82 of 2001. The analysis showed that all samples were at mild to moderate pollution levels, and did not meet class III water quality standards. Multiple regression analysis produced two equations, namely: Model 1: PI = 3.952 + 91.668 Phenol and Model 2: PI = 3.086 + 80.167 Phenol + 0.152 BOD, with R squared values of 53% and 69.9% with a confidence level of 0.005. Thus the prediction of pollution levels of similar watershed can be made only by using the two most influential parameters namely phenol and/or BOD alone. </dc:description>
<dc:publisher xml:lang="en-US">Faculty of Geography, Universitas Gadjah Mada</dc:publisher>
<dc:contributor xml:lang="en-US">Balai Penelitian dan Pengembangan Teknologi Pengelolaan Daerah Aliran Sungai (Watershed Management Technology Center)</dc:contributor>
<dc:date>2020-09-02</dc:date>
<dc:type>info:eu-repo/semantics/article</dc:type>
<dc:type>info:eu-repo/semantics/publishedVersion</dc:type>
<dc:type xml:lang="en-US">Peer-reviewed Article</dc:type>
<dc:type xml:lang="en-US">Survey and laboratory analysis</dc:type>
<dc:format>application/pdf</dc:format>
<dc:identifier>https://journal.ugm.ac.id/ijg/article/view/47280</dc:identifier>
<dc:identifier>10.22146/ijg.47280</dc:identifier>
<dc:source xml:lang="en-US">Indonesian Journal of Geography; Vol 52, No 2 (2020): Indonesian Journal of Geography; 227-238</dc:source>
<dc:source>2354-9114</dc:source>
<dc:source>0024-9521</dc:source>
<dc:language>eng</dc:language>
<dc:relation>https://journal.ugm.ac.id/ijg/article/view/47280/pdf</dc:relation>
<dc:coverage xml:lang="en-US">Brantas and Bengawan Solo watersheds</dc:coverage>
<dc:coverage xml:lang="en-US"></dc:coverage>
<dc:coverage xml:lang="en-US">Water Sampling of Non Point Source Pollution</dc:coverage>
<dc:rights xml:lang="en-US">Copyright (c) 2020 Authors</dc:rights>
<dc:rights xml:lang="en-US">http://creativecommons.org/licenses/by-nc/4.0</dc:rights>
</oai_dc:dc>
Sitasi dan pengindeksan
Jumlah menurut tiap indeks pada 13 Nov 2026; setiap indeks menghitung sitasi dengan cara berbeda.
OpenAlex juga mencatat karya ini di: crossref.
Sitasi artikel ini
APA 7
Susanti, P. D., & Wahyuningrum, N. (2020). Identification of the Main Water Quality Parameters for Monitoring and Evaluating Watershed Health. Indonesian Journal of Geography, 52(2), 227–238. https://doi.org/10.22146/ijg.47280
Salin
IEEE
P. D. Susanti and N. Wahyuningrum, “Identification of the Main Water Quality Parameters for Monitoring and Evaluating Watershed Health,” Indonesian Journal of Geography, vol. 52, no. 2, pp. 227–238, 2020, doi: 10.22146/ijg.47280.
Salin
Dibuat dari metadata jurnal; periksa nama penulis sebelum dipakai.