Melola Discovery

← Melola Discovery

Akses terbuka Jurnal SINTA 1

SAIDI and SAIFI indicators for the control of feeder A4502 of the Concepción transformer electrical substation

International Journal of Advances in Applied Sciences · Vol. 15 No. 1 (2026) · hlm. 396–404

DOI
10.11591/ijaas.v15.i1.pp396-404
ISSN
2722-2594, 2252-8814
Terbit
2026-03-01
Penerbit
Institute of Advanced Engineering and Science
Bahasa
eng
Lisensi
creativecommons.org/licenses/by-sa/4.0

Abstrak

This study evaluated the reliability of feeder A4502 of the Concepción substation (Huancayo, Peru) through the analysis of system average interruption duration index (SAIDI) and system average interruption frequency index (SAIFI) indicators. The 46-year-old infrastructure presented 805 structural deficiencies (59%), with a predominance of corrosion in iron poles. Automatic recloser devices were implemented at strategic points, based on the fact that 67% of the 73 interruptions in 2021 were transient faults. Post-intervention results (2024) showed significant improvements: SAIDI was reduced from 9.87 to 7.39 hours (25%), nearing the regulatory limit of 7 hours; SAIFI decreased from 4.29 to 2.71 events (37%), falling within the limit of 4. Pearson correlation analysis confirmed a statistically significant relationship between structural deficiencies and the indicators (r =0.62 SAIDI, r =0.58 SAIFI, p <0.05). The integrated approach—diagnosis of deficiencies + automation with reclosers—proved to be technically viable and economically justifiable, also allowing for the meeting of new energy demands (240 kVA available). The results constitute a replicable model for other aging Latin American networks, validating the viability of regulatory compliance without prohibitive investments.

Jaringan kolaborasi para penulis

24 penulis · 105 tautan kepenulisan bersama · 74 lintas organisasi

Arahkan kursor atau ketuk sebuah nama untuk menyorot rekan penulisnya. Klik dua kali untuk membuka halaman penulis.

  • Universidad Nacional Tecnológica de Lima Sur
  • National University of Education Enrique Guzmán y Valle
  • Universidad Nacional del Callao
  • National University of Engineering
  • Universidad Tecnológica del Perú
  • Peruvian University of Applied Sciences
  • National University of San Marcos
  • Organisasi lain
  • Organisasi berbeda
  • Organisasi sama
  • Afiliasi tidak diketahui
  • Garis lebih tebal = lebih banyak artikel bersama · lingkaran lebih besar = lebih banyak artikel
Tampilkan sebagai tabel
Rekan penulisOrganisasiArtikel bersama
Javier Sinche CcahuanaUniversidad Nacional Tecnológica de Lima Sur3
Carlos Dávila-IgnacioUniversidad Nacional Tecnológica de Lima Sur2
Orlando Ortega-GalicioUniversidad Nacional Tecnológica de Lima Sur2
Antonio A. Meléndez MurilloNational University of Engineering2
Guillermo Morales-RomeroNational University of Education Enrique Guzmán y Valle1
Nicéforo Trinidad-LoliNational University of Education Enrique Guzmán y Valle1
Beatriz Caycho-SalasNational University of Education Enrique Guzmán y Valle1
Elizabeth Auqui-RamosNational University of Education Enrique Guzmán y Valle1
César León-VelardeUniversidad Tecnológica del Perú1
Renan Edison Auqui RamosPeruvian University of Applied Sciences1
Maribel Cardenas YauriNational University of Engineering1
Jacinto Joaquín Vértiz-OsoresUniversidad Nacional Tecnológica de Lima Sur1
Zanhy Leonor Valencia ReyesNational University of San Marcos1
Florcita Aldana-TrejoFederico Villarreal National University1
Nestor Alvarado-BravoUniversidad Nacional del Callao1
Almintor Torres-QuirozUniversidad Nacional del Callao1
Teodoro Díaz-LeyvaUniversidad Nacional Tecnológica de Lima Sur1
Soledad Olivares-ZegarraUniversidad Nacional Tecnológica de Lima Sur1
Salvador Apolinar Trujillo-PérezUniversidad Nacional del Callao1
José Razo-QuispeUniversidad Privada San Juan Bautista1

Afiliasi berasal dari OpenAlex; metadata OAI-PMH jurnal tidak memuatnya. Penulis tanpa ID OpenAlex dicocokkan berdasarkan nama, sehingga dua orang bisa tergabung atau satu orang bisa terpisah.

Sumber metadata: OAI-PMH (metadata jurnal) http://ijaas.iaescore.com/index.php/IJAAS/oai, pertama di-harvest 8 Nov 2026, terakhir terlihat 22 Nov 2026.
Metadata asli (oai_dc)
<oai_dc:dc xmlns="http://www.openarchives.org/OAI/2.0/" xmlns:dc="http://purl.org/dc/elements/1.1/" xmlns:oai_dc="http://www.openarchives.org/OAI/2.0/oai_dc/" xmlns:xsi="http://www.w3.org/2001/XMLSchema-instance" xsi:schemaLocation="http://www.openarchives.org/OAI/2.0/oai_dc/  http://www.openarchives.org/OAI/2.0/oai_dc.xsd">
	<dc:title xml:lang="en-US">SAIDI and SAIFI indicators for the control of feeder A4502 of  the Concepción transformer electrical substation</dc:title>
	<dc:creator>Murillo Manrique, Margarita F.</dc:creator>
	<dc:creator>Sánchez Ayte, Jorge Augusto</dc:creator>
	<dc:creator>Joel Baygorrea Vega, William</dc:creator>
	<dc:creator>Flores-Caceres, Richard</dc:creator>
	<dc:description xml:lang="en-US">This study evaluated the reliability of feeder A4502 of the Concepción substation (Huancayo, Peru) through the analysis of system average interruption duration index (SAIDI) and system average interruption frequency index (SAIFI) indicators. The 46-year-old infrastructure presented 805 structural deficiencies (59%), with a predominance of corrosion in iron poles. Automatic recloser devices were implemented at strategic points, based on the fact that 67% of the 73 interruptions in 2021 were transient faults. Post-intervention results (2024) showed significant improvements: SAIDI was reduced from 9.87 to 7.39 hours (25%), nearing the regulatory limit of 7 hours; SAIFI decreased from 4.29 to 2.71 events (37%), falling within the limit of 4. Pearson correlation analysis confirmed a statistically significant relationship between structural deficiencies and the indicators (r =0.62 SAIDI, r =0.58 SAIFI, p &amp;lt;0.05). The integrated approach—diagnosis of deficiencies + automation with reclosers—proved to be technically viable and economically justifiable, also allowing for the meeting of new energy demands (240 kVA available). The results constitute a replicable model for other aging Latin American networks, validating the viability of regulatory compliance without prohibitive investments.</dc:description>
	<dc:publisher xml:lang="en-US">Institute of Advanced Engineering and Science</dc:publisher>
	<dc:contributor xml:lang="en-US"></dc:contributor>
	<dc:date>2026-03-01</dc:date>
	<dc:type>info:eu-repo/semantics/article</dc:type>
	<dc:type>info:eu-repo/semantics/publishedVersion</dc:type>
	<dc:type xml:lang="en-US"></dc:type>
	<dc:format>application/pdf</dc:format>
	<dc:identifier>https://ijaas.iaescore.com/index.php/IJAAS/article/view/22118</dc:identifier>
	<dc:identifier>10.11591/ijaas.v15.i1.pp396-404</dc:identifier>
	<dc:source xml:lang="en-US">International Journal of Advances in Applied Sciences; Vol 15, No 1: March 2026; 396-404</dc:source>
	<dc:source>2722-2594</dc:source>
	<dc:source>2252-8814</dc:source>
	<dc:source>10.11591/ijaas.v15.i1</dc:source>
	<dc:language>eng</dc:language>
	<dc:relation>https://ijaas.iaescore.com/index.php/IJAAS/article/view/22118/13423</dc:relation>
	<dc:rights xml:lang="en-US">Copyright (c) 2026 Jorge Augusto Sanchez Ayte, Margarita Fredesvinda Murillo-Manrique</dc:rights>
	<dc:rights xml:lang="en-US">http://creativecommons.org/licenses/by-sa/4.0</dc:rights>
</oai_dc:dc>