Melola Discovery

← Melola Discovery

Akses terbuka Jurnal SINTA 1

Design of Robust Load Frequency Controller for Multi-Area Interconnected Power System Using SDO Software

International Journal of Advances in Applied Sciences · Vol. 6 No. 1 (2017) · hlm. 12–22

DOI
10.11591/ijaas.v6.i1.pp12-22
ISSN
2722-2594, 2252-8814
Terbit
2017-03-01
Penerbit
Institute of Advanced Engineering and Science
Bahasa
eng
Lisensi
creativecommons.org/licenses/by-sa/4.0

Abstrak

The response of the load frequency control problem in multi-area interconnected electrical power system is much more complex with increasing size, changing structure and increasing load. This paper deals with Load Frequency Control of three area interconnected Power system incorporating Reheat, Non-reheat and Reheat turbines in all areas respectively. The response of the load frequency control problem in a multi-area interconnected power system is improved by designing PID controller using different tuning techniques and proved that the PID controller which was designed by Simulink Design Optimization (SDO) Software gives the superior performance than other controllers for step perturbations. Finally the robustness of controller was checked against system parameter variations..

Jaringan kolaborasi para penulis

9 penulis · 15 tautan kepenulisan bersama · 7 lintas organisasi

Arahkan kursor atau ketuk sebuah nama untuk menyorot rekan penulisnya. Klik dua kali untuk membuka halaman penulis.

  • Koneru Lakshmaiah Education Foundation
  • Sri Venkateswara University
  • Electrical Research and Development Association
  • Sri Venkateswara College of Engineering Tirupati
  • Afiliasi tidak diketahui
  • Organisasi berbeda
  • Organisasi sama
  • Afiliasi tidak diketahui
  • Garis lebih tebal = lebih banyak artikel bersama · lingkaran lebih besar = lebih banyak artikel
Tampilkan sebagai tabel
Rekan penulisOrganisasiArtikel bersama
N. Ramesh RajuAfiliasi tidak diketahui2
Abbineni Sai SubhadraKoneru Lakshmaiah Education Foundation1
Shailesh B. ModiElectrical Research and Development Association1
Manubolu Damodar ReddySri Venkateswara University1
Suresh Babu PalepuSri Venkateswara University1
D. SarikaAfiliasi tidak diketahui1
Suresh Babu PotladurtySri Venkateswara College of Engineering Tirupati1

Afiliasi berasal dari OpenAlex; metadata OAI-PMH jurnal tidak memuatnya. Penulis tanpa ID OpenAlex dicocokkan berdasarkan nama, sehingga dua orang bisa tergabung atau satu orang bisa terpisah.

Sumber metadata: OAI-PMH (metadata jurnal) http://ijaas.iaescore.com/index.php/IJAAS/oai, pertama di-harvest 8 Nov 2026, terakhir terlihat 16 Nov 2026.
Metadata asli (oai_dc)
<oai_dc:dc xmlns="http://www.openarchives.org/OAI/2.0/" xmlns:dc="http://purl.org/dc/elements/1.1/" xmlns:oai_dc="http://www.openarchives.org/OAI/2.0/oai_dc/" xmlns:xsi="http://www.w3.org/2001/XMLSchema-instance" xsi:schemaLocation="http://www.openarchives.org/OAI/2.0/oai_dc/  http://www.openarchives.org/OAI/2.0/oai_dc.xsd">
	<dc:title xml:lang="en-US">Design of Robust Load Frequency Controller for Multi-Area Interconnected Power System Using SDO Software</dc:title>
	<dc:creator>Gopi, Pasala</dc:creator>
	<dc:creator>Reddy, P. Linga</dc:creator>
	<dc:description xml:lang="en-US">The response of the load frequency control problem in multi-area interconnected electrical power system is much more complex with increasing size, changing structure and increasing load.  This paper deals with Load Frequency Control of three area interconnected Power system incorporating Reheat, Non-reheat and Reheat turbines in all areas respectively.  The response of the load frequency control problem in a multi-area interconnected power system is improved by designing PID controller using different tuning techniques and proved that the PID controller which was designed by Simulink Design Optimization (SDO) Software gives the superior performance than other controllers for step perturbations. Finally the robustness of controller was checked against system parameter variations..</dc:description>
	<dc:publisher xml:lang="en-US">Institute of Advanced Engineering and Science</dc:publisher>
	<dc:date>2017-03-01</dc:date>
	<dc:type>info:eu-repo/semantics/article</dc:type>
	<dc:type>info:eu-repo/semantics/publishedVersion</dc:type>
	<dc:type xml:lang="en-US"></dc:type>
	<dc:format>application/pdf</dc:format>
	<dc:identifier>https://ijaas.iaescore.com/index.php/IJAAS/article/view/8575</dc:identifier>
	<dc:identifier>10.11591/ijaas.v6.i1.pp12-22</dc:identifier>
	<dc:source xml:lang="en-US">International Journal of Advances in Applied Sciences; Vol 6, No 1: March 2017; 12-22</dc:source>
	<dc:source>2722-2594</dc:source>
	<dc:source>2252-8814</dc:source>
	<dc:source>10.11591/ijaas.v6.i1</dc:source>
	<dc:language>eng</dc:language>
	<dc:relation>https://ijaas.iaescore.com/index.php/IJAAS/article/view/8575/7760</dc:relation>
	<dc:rights xml:lang="en-US">Copyright (c) 2017 Pasala Gopi, P. Linga Reddy</dc:rights>
	<dc:rights xml:lang="en-US">http://creativecommons.org/licenses/by-sa/4.0</dc:rights>
</oai_dc:dc>