Melola Discovery

← Melola Discovery

Akses terbuka Jurnal SINTA 1

Automatic slice thickness measurement on computed tomography images of American College of Radiology phantom

International Journal of Advances in Applied Sciences · Vol. 13 No. 2 (2024) · hlm. 371–379

DOI
10.11591/ijaas.v13.i2.pp371-379
ISSN
2722-2594, 2252-8814
Terbit
2024-06-01
Penerbit
Institute of Advanced Engineering and Science
Bahasa
eng
Lisensi
creativecommons.org/licenses/by-sa/4.0

Abstrak

This study aims to develop an automatic method for calculating slice thickness on an American College of Radiology (ACR) phantom and evaluate its accuracy at variations of orientation angle and slice thickness. The phantom was scanned using Siemens SOMATOM perspective, with variations of the slice thickness (i.e. 1.5, 3, 5, 6, 7, and 10 mm) and rotation angles (i.e. 0.0, 22.5, 45.0, and 67.5°). The phantom rotation was based on the bone object as a reference. After determining the rotation angle, the phantom image was rotated by the angle. Next, profiles of pixel values across the wire objects for measuring slice thickness were developed from rotated phantom images. The slice thickness was measured automatically from the obtained profiles. The results of the automated method are 2.5, 4.1, 5.4, 5.8, 7.8, and 9.8 mm for all varied slice thicknesses. The differences between the automatic and manual methods are within 0.3 mm. The automatic method is capable of detecting slice thickness for various angles. The differences in slice thickness for various angles are within 0.1 mm for a slice thickness of 3 mm. These results are similar when compared to manual measurements. An algorithm for automated slice thickness measurement on ACR phantom has been successfully developed.

Jaringan kolaborasi para penulis

40 penulis · 115 tautan kepenulisan bersama · 62 lintas organisasi · menampilkan 40 yang paling banyak terhubung

Arahkan kursor atau ketuk sebuah nama untuk menyorot rekan penulisnya. Klik dua kali untuk membuka halaman penulis.

  • Diponegoro University
  • Universiti Sains Malaysia
  • Bandung Institute of Technology
  • University of Indonesia
  • Pertamina (Indonesia)
  • Ministry of Health
  • Rumah Sakit Umum Pusat Nasional Dr. Cipto Mangunkusumo
  • Organisasi lain
  • Afiliasi tidak diketahui
  • Organisasi berbeda
  • Organisasi sama
  • Afiliasi tidak diketahui
  • Garis lebih tebal = lebih banyak artikel bersama · lingkaran lebih besar = lebih banyak artikel
Tampilkan sebagai tabel
Rekan penulisOrganisasiArtikel bersama
Geoff DoughertyCalifornia State University, Channel Islands6
Fajar AriantoDiponegoro University2
Freddy HaryantoBandung Institute of Technology2
Annisa Lidia WatiDiponegoro University2
Arrum NitasariDiponegoro University2
S SyarifudinDr. Kariadi Hospital2
Wahyu SetiabudiDiponegoro University2
Wahyu Setia BudiDiponegoro University2
N.P. ViantriDiponegoro University1
F. NadzirPertamina (Indonesia)1
Chavied VarunaPertamina (Indonesia)1
F. M. SalimDiponegoro University1
Rena WiditaBandung Institute of Technology1
Idam ArifBandung Institute of Technology1
Imam KambaliNational Nuclear Energy Agency of Indonesia1
Muhammad RezkiDiponegoro University1
Mohamad Fahdillah RhaniTan Tock Seng Hospital1
S. YaniIPB University1
S. SofiyatunDiponegoro University1
Ummu Mar'atu ZahroDiponegoro University1
Dito Andi RukmanaAfiliasi tidak diketahui1
M. T. SaidinMinistry of Health1
Azhar Abdul RahmanUniversiti Sains Malaysia1
Hanif Haspi HarunMinistry of Health1
Yasmin Md RadziUniversiti Sains Malaysia1
Zunaide KayunGovernment of Malaysia1
Titi AmaliaUniversity of Indonesia1
Benny ZulkarnaienUniversity of Indonesia1
K. NurcahyoUniversity of Indonesia1
H. TussyadiahRumah Sakit Umum Pusat Nasional Dr. Cipto Mangunkusumo1
D. E. PradanaRumah Sakit Umum Pusat Nasional Dr. Cipto Mangunkusumo1
Hamza ArjahUniversiti Sains Malaysia1
Noor Diyana OsmanUniversiti Sains Malaysia1

Afiliasi berasal dari OpenAlex; metadata OAI-PMH jurnal tidak memuatnya. Penulis tanpa ID OpenAlex dicocokkan berdasarkan nama, sehingga dua orang bisa tergabung atau satu orang bisa terpisah.

Sumber metadata: OAI-PMH (metadata jurnal) http://ijaas.iaescore.com/index.php/IJAAS/oai, pertama di-harvest 8 Nov 2026, terakhir terlihat 22 Nov 2026.
Metadata asli (oai_dc)
<oai_dc:dc xmlns="http://www.openarchives.org/OAI/2.0/" xmlns:dc="http://purl.org/dc/elements/1.1/" xmlns:oai_dc="http://www.openarchives.org/OAI/2.0/oai_dc/" xmlns:xsi="http://www.w3.org/2001/XMLSchema-instance" xsi:schemaLocation="http://www.openarchives.org/OAI/2.0/oai_dc/  http://www.openarchives.org/OAI/2.0/oai_dc.xsd">
	<dc:title xml:lang="en-US">Automatic slice thickness measurement on computed tomography images of American College of Radiology phantom</dc:title>
	<dc:creator>Anam, Choirul</dc:creator>
	<dc:creator>Insiano, Dewi A.</dc:creator>
	<dc:creator>Hidayanto, Eko</dc:creator>
	<dc:creator>Naufal, Ariij</dc:creator>
	<dc:creator>Maya, Annisa Tenri</dc:creator>
	<dc:creator>Mulatomo, Tunggul Drajat</dc:creator>
	<dc:creator>Ali, Mohd Hanafi</dc:creator>
	<dc:description xml:lang="en-US">This study aims to develop an automatic method for calculating slice thickness on an American College of Radiology (ACR) phantom and evaluate its accuracy at variations of orientation angle and slice thickness. The phantom was scanned using Siemens SOMATOM perspective, with variations of the slice thickness (i.e. 1.5, 3, 5, 6, 7, and 10 mm) and rotation angles (i.e. 0.0, 22.5, 45.0, and 67.5°). The phantom rotation was based on the bone object as a reference. After determining the rotation angle, the phantom image was rotated by the angle. Next, profiles of pixel values across the wire objects for measuring slice thickness were developed from rotated phantom images. The slice thickness was measured automatically from the obtained profiles. The results of the automated method are 2.5, 4.1, 5.4, 5.8, 7.8, and 9.8 mm for all varied slice thicknesses. The differences between the automatic and manual methods are within 0.3 mm. The automatic method is capable of detecting slice thickness for various angles. The differences in slice thickness for various angles are within 0.1 mm for a slice thickness of 3 mm. These results are similar when compared to manual measurements. An algorithm for automated slice thickness measurement on ACR phantom has been successfully developed.</dc:description>
	<dc:publisher xml:lang="en-US">Institute of Advanced Engineering and Science</dc:publisher>
	<dc:contributor xml:lang="en-US"></dc:contributor>
	<dc:date>2024-06-01</dc:date>
	<dc:type>info:eu-repo/semantics/article</dc:type>
	<dc:type>info:eu-repo/semantics/publishedVersion</dc:type>
	<dc:type xml:lang="en-US"></dc:type>
	<dc:format>application/pdf</dc:format>
	<dc:identifier>https://ijaas.iaescore.com/index.php/IJAAS/article/view/21173</dc:identifier>
	<dc:identifier>10.11591/ijaas.v13.i2.pp371-379</dc:identifier>
	<dc:source xml:lang="en-US">International Journal of Advances in Applied Sciences; Vol 13, No 2: June 2024; 371-379</dc:source>
	<dc:source>2722-2594</dc:source>
	<dc:source>2252-8814</dc:source>
	<dc:source>10.11591/ijaas.v13.i2</dc:source>
	<dc:language>eng</dc:language>
	<dc:relation>https://ijaas.iaescore.com/index.php/IJAAS/article/view/21173/13115</dc:relation>
	<dc:rights xml:lang="en-US">Copyright (c) 2024 Institute of Advanced Engineering and Science (IAES)</dc:rights>
	<dc:rights xml:lang="en-US">http://creativecommons.org/licenses/by-sa/4.0</dc:rights>
</oai_dc:dc>