Melola Discovery

← Melola Discovery

Akses terbuka Jurnal SINTA 1

Healthy building phytoarchitecture requires essential criteria for sustainable phylloremediation of contaminated indoor air

International Journal of Advances in Applied Sciences · Vol. 13 No. 3 (2024) · hlm. 662–672

DOI
10.11591/ijaas.v13.i3.pp662-672
ISSN
2722-2594, 2252-8814
Terbit
2024-09-01
Penerbit
Institute of Advanced Engineering and Science
Bahasa
eng
Lisensi
creativecommons.org/licenses/by-sa/4.0

Abstrak

Various ambient air contaminants can spread into the indoor building through air transport. With the additional generation of contaminants from indoor activities, indoor air quality (IAQ) has the potential to be polluted. Indoor air pollution incidents can occur anytime, which is difficult to predict. Therefore, it is necessary to take action to improve IAQ as early as possible and sustainably. The solution to sustainable remediation is using plants to apply phylloremediation, which functions as leaves and leaf-associated microbial communities to reduce air contaminants. This study aims to provide new practical yet essential criteria for the sustainable operation of phylloremediation. This review is based on the latest results of a literature-based study. An analysis of the fundamental processes of plant life forms the basis for obtaining these criteria. The study emphasizes key criteria for phylloremediation encompassing the selecting plants with high transpiration and leaf-microbe synergy, and conducting maintenance by spraying water on leaves. These measures optimize efficiency and sustain the process for indoor air pollutant reduction. The final result summarises the new criteria for sustainable phylloremediation to maintain plant life. These essential criteria can be used for conducting experiments in empirical research, indoor design, and education for the community.

Jaringan kolaborasi para penulis

15 penulis · 36 tautan kepenulisan bersama · 23 lintas organisasi

Arahkan kursor atau ketuk sebuah nama untuk menyorot rekan penulisnya. Klik dua kali untuk membuka halaman penulis.

  • Universitas Islam Negeri Maulana Malik Ibrahim
  • Diponegoro University
  • Institut Teknologi Sepuluh Nopember
  • Universitas Halu Oleo
  • Institut Teknologi PLN
  • Universiti Teknologi MARA
  • National Research and Innovation Agency
  • Organisasi berbeda
  • Organisasi sama
  • Afiliasi tidak diketahui
  • Garis lebih tebal = lebih banyak artikel bersama · lingkaran lebih besar = lebih banyak artikel
Tampilkan sebagai tabel
Rekan penulisOrganisasiArtikel bersama
Dwi Rinnarsuri NoraduolaUniversitas Halu Oleo4
Azzah Nazihah Che Abdul RahimUniversiti Teknologi MARA3
Budi WijayaDiponegoro University1
Sudarno SudarnoDiponegoro University1
Rachmad ArdhiantoInstitut Teknologi PLN1
Aldrin Yusuf FirmansyahUniversitas Islam Negeri Maulana Malik Ibrahim1
Farid NazaruddinUniversitas Islam Negeri Maulana Malik Ibrahim1
Prima KurniawatyUniversitas Islam Negeri Maulana Malik Ibrahim1
Ipung Fitri PurwantiInstitut Teknologi Sepuluh Nopember1
R. Irwan Bagyo SantosoInstitut Teknologi Sepuluh Nopember1
Laode M. Golok JayaUniversitas Halu Oleo1
Rusli CahyadiNational Research and Innovation Agency1

Afiliasi berasal dari OpenAlex; metadata OAI-PMH jurnal tidak memuatnya. Penulis tanpa ID OpenAlex dicocokkan berdasarkan nama, sehingga dua orang bisa tergabung atau satu orang bisa terpisah.

Sumber metadata: OAI-PMH (metadata jurnal) http://ijaas.iaescore.com/index.php/IJAAS/oai, pertama di-harvest 8 Nov 2026, terakhir terlihat 8 Nov 2026.
Metadata asli (oai_dc)
<oai_dc:dc xmlns="http://www.openarchives.org/OAI/2.0/" xmlns:dc="http://purl.org/dc/elements/1.1/" xmlns:oai_dc="http://www.openarchives.org/OAI/2.0/oai_dc/" xmlns:xsi="http://www.w3.org/2001/XMLSchema-instance" xsi:schemaLocation="http://www.openarchives.org/OAI/2.0/oai_dc/  http://www.openarchives.org/OAI/2.0/oai_dc.xsd">
	<dc:title xml:lang="en-US">Healthy building phytoarchitecture requires essential criteria for sustainable phylloremediation of contaminated indoor air</dc:title>
	<dc:creator>Samudro, Ganjar</dc:creator>
	<dc:creator>Samudro, Harida</dc:creator>
	<dc:creator>Mangkoedihardjo, Sarwoko</dc:creator>
	<dc:description xml:lang="en-US">Various ambient air contaminants can spread into the indoor building through air transport. With the additional generation of contaminants from indoor activities, indoor air quality (IAQ) has the potential to be polluted. Indoor air pollution incidents can occur anytime, which is difficult to predict. Therefore, it is necessary to take action to improve IAQ as early as possible and sustainably. The solution to sustainable remediation is using plants to apply phylloremediation, which functions as leaves and leaf-associated microbial communities to reduce air contaminants. This study aims to provide new practical yet essential criteria for the sustainable operation of phylloremediation. This review is based on the latest results of a literature-based study. An analysis of the fundamental processes of plant life forms the basis for obtaining these criteria. The study emphasizes key criteria for phylloremediation encompassing the selecting plants with high transpiration and leaf-microbe synergy, and conducting maintenance by spraying water on leaves. These measures optimize efficiency and sustain the process for indoor air pollutant reduction. The final result summarises the new criteria for sustainable phylloremediation to maintain plant life. These essential criteria can be used for conducting experiments in empirical research, indoor design, and education for the community.</dc:description>
	<dc:publisher xml:lang="en-US">Institute of Advanced Engineering and Science</dc:publisher>
	<dc:contributor xml:lang="en-US"></dc:contributor>
	<dc:date>2024-09-01</dc:date>
	<dc:type>info:eu-repo/semantics/article</dc:type>
	<dc:type>info:eu-repo/semantics/publishedVersion</dc:type>
	<dc:type xml:lang="en-US"></dc:type>
	<dc:format>application/pdf</dc:format>
	<dc:identifier>https://ijaas.iaescore.com/index.php/IJAAS/article/view/21070</dc:identifier>
	<dc:identifier>10.11591/ijaas.v13.i3.pp662-672</dc:identifier>
	<dc:source xml:lang="en-US">International Journal of Advances in Applied Sciences; Vol 13, No 3: September 2024; 662-672</dc:source>
	<dc:source>2722-2594</dc:source>
	<dc:source>2252-8814</dc:source>
	<dc:source>10.11591/ijaas.v13.i3</dc:source>
	<dc:language>eng</dc:language>
	<dc:relation>https://ijaas.iaescore.com/index.php/IJAAS/article/view/21070/13156</dc:relation>
	<dc:rights xml:lang="en-US">Copyright (c) 2024 Institute of Advanced Engineering and Science (IAES)</dc:rights>
	<dc:rights xml:lang="en-US">http://creativecommons.org/licenses/by-sa/4.0</dc:rights>
</oai_dc:dc>