Melola Discovery

← Melola Discovery

Akses terbuka Jurnal SINTA 1

Influences of Hybrid Cooling Mechanism through PV System under Solar Simulator Testing

International Journal of Advances in Applied Sciences · Vol. 6 No. 3 (2017) · hlm. 213–220

DOI
10.11591/ijaas.v6.i3.pp213-220
ISSN
2722-2594, 2252-8814
Terbit
2017-09-01
Penerbit
Institute of Advanced Engineering and Science
Bahasa
eng
Lisensi
creativecommons.org/licenses/by-sa/4.0

Abstrak

An increasing efficiency of the solar system can be improved by using hybrid cooling mechanism. This paper presents the impact of hybrid cooling mechanism on PV panel under indoor testing with varying solar intensity. Thus, the fabrication of a solar simulator for indoor testing reacts as the space solar radiation is described. The performance of PV panel which attached to a hybrid cooling mechanism compared with PV panel without cooling mechanism under variation of average solar radiation. Experimental tests were carried out for various average solar radiations by varying the number of lamps and/or the lamp-to-area distance. Without altering the spectral distribution, the characteristic of current-voltage of PV panel was analysed under average solar radiation which varied from 202 W/m2 to 1003 W/m2. As the result, the PV panel with hybrid cooling system explored to generate more power output with decreasing in PV panel temperature. About 15.79 % increment of power output generated by PV panel with cooling at maximum average solar radiation. Furthermore, the PV panel temperature also can be decreased about 10.28 % respectively. The combination of DC fan and water pump as cooling mechanism plays an important role in generating efficient power output from PV panel.

Jaringan kolaborasi para penulis

26 penulis · 87 tautan kepenulisan bersama · 30 lintas organisasi

Arahkan kursor atau ketuk sebuah nama untuk menyorot rekan penulisnya. Klik dua kali untuk membuka halaman penulis.

  • Universiti Malaysia Perlis
  • Medan Area University
  • Institut Teknologi Medan
  • Tanjungpura University
  • Andalas University
  • Universitas Prima Indonesia
  • Universitas Muhammadiyah Sumatera Utara
  • Afiliasi tidak diketahui
  • Organisasi berbeda
  • Organisasi sama
  • Afiliasi tidak diketahui
  • Garis lebih tebal = lebih banyak artikel bersama · lingkaran lebih besar = lebih banyak artikel
Tampilkan sebagai tabel
Rekan penulisOrganisasiArtikel bersama
Nair GomeshUniversiti Malaysia Perlis10
Muhammad Afizi AnuarUniversiti Malaysia Perlis10
M. IrwantoUniversitas Prima Indonesia2
H. AlamInstitut Teknologi Medan2
Baharuddin IsmailUniversiti Malaysia Perlis2
Mahrizal MasriInstitut Teknologi Medan2
Mohd Irwan YusoffUniversiti Malaysia Perlis1
Muhammad Irwanto MisrunUniversiti Malaysia Perlis1
Mohd Fareq Abd MalekUniversiti Malaysia Perlis1
Amelia Abdul RazakUniversiti Malaysia Perlis1
Gomesh Nair A/L ShasidharanAfiliasi tidak diketahui1
Safwati IbrahimUniversiti Malaysia Perlis1
Habib SatriaMedan Area University1
Syafii SyafiiAndalas University1
Indri DayanaMedan Area University1
Dadan RamdanMedan Area University1
Muhammad Fadlan SiregarMedan Area University1
Ayong HiendroTanjungpura University1
Suwarno SuwarnoUniversitas Muhammadiyah Sumatera Utara1
Ismail YusufTanjungpura University1

Afiliasi berasal dari OpenAlex; metadata OAI-PMH jurnal tidak memuatnya. Penulis tanpa ID OpenAlex dicocokkan berdasarkan nama, sehingga dua orang bisa tergabung atau satu orang bisa terpisah.

Sumber metadata: OAI-PMH (metadata jurnal) http://ijaas.iaescore.com/index.php/IJAAS/oai, pertama di-harvest 8 Nov 2026, terakhir terlihat 8 Nov 2026.
Metadata asli (oai_dc)
<oai_dc:dc xmlns="http://www.openarchives.org/OAI/2.0/" xmlns:dc="http://purl.org/dc/elements/1.1/" xmlns:oai_dc="http://www.openarchives.org/OAI/2.0/oai_dc/" xmlns:xsi="http://www.w3.org/2001/XMLSchema-instance" xsi:schemaLocation="http://www.openarchives.org/OAI/2.0/oai_dc/  http://www.openarchives.org/OAI/2.0/oai_dc.xsd">
	<dc:title xml:lang="en-US">Influences of Hybrid Cooling Mechanism through PV System under Solar Simulator Testing</dc:title>
	<dc:creator>Irwan, Y.M.</dc:creator>
	<dc:creator>Amelia, A.R.</dc:creator>
	<dc:creator>Irwanto, M.</dc:creator>
	<dc:creator>Leow, W.Z.</dc:creator>
	<dc:creator>Syafiqah, Z.</dc:creator>
	<dc:creator>Safwati, I.</dc:creator>
	<dc:description xml:lang="en-US">An increasing efficiency of the solar system can be improved by using hybrid cooling mechanism. This paper presents the impact of hybrid cooling mechanism on PV panel under indoor testing with varying solar intensity. Thus, the fabrication of a solar simulator for indoor testing reacts as the space solar radiation is described. The performance of PV panel which attached to a hybrid cooling mechanism compared with PV panel without cooling mechanism under variation of average solar radiation. Experimental tests were carried out for various average solar radiations by varying the number of lamps and/or the lamp-to-area distance. Without altering the spectral distribution, the characteristic of current-voltage of PV panel was analysed under average solar radiation which varied from 202 W/m2 to 1003 W/m2. As the result, the PV panel with hybrid cooling system explored to generate more power output with decreasing in PV panel temperature. About 15.79 % increment of power output generated by PV panel with cooling at maximum average solar radiation. Furthermore, the PV panel temperature also can be decreased about 10.28 % respectively. The combination of DC fan and water pump as cooling mechanism plays an important role in generating efficient power output from PV panel.</dc:description>
	<dc:publisher xml:lang="en-US">Institute of Advanced Engineering and Science</dc:publisher>
	<dc:date>2017-09-01</dc:date>
	<dc:type>info:eu-repo/semantics/article</dc:type>
	<dc:type>info:eu-repo/semantics/publishedVersion</dc:type>
	<dc:type xml:lang="en-US"></dc:type>
	<dc:format>application/pdf</dc:format>
	<dc:identifier>https://ijaas.iaescore.com/index.php/IJAAS/article/view/8784</dc:identifier>
	<dc:identifier>10.11591/ijaas.v6.i3.pp213-220</dc:identifier>
	<dc:source xml:lang="en-US">International Journal of Advances in Applied Sciences; Vol 6, No 3: September 2017; 213-220</dc:source>
	<dc:source>2722-2594</dc:source>
	<dc:source>2252-8814</dc:source>
	<dc:source>10.11591/ijaas.v6.i3</dc:source>
	<dc:language>eng</dc:language>
	<dc:relation>https://ijaas.iaescore.com/index.php/IJAAS/article/view/8784/7837</dc:relation>
	<dc:rights xml:lang="en-US">Copyright (c) 2017 Y.M. Irwan, A.R. Amelia, M. Irwanto, W.Z. Leow, Z. Syafiqah, I. Safwati</dc:rights>
	<dc:rights xml:lang="en-US">http://creativecommons.org/licenses/by-sa/4.0</dc:rights>
</oai_dc:dc>