Melola Discovery

← Melola Discovery

Akses terbuka Jurnal SINTA 1

Review on electrical submersible pump failures detection and monitoring system

International Journal of Advances in Applied Sciences · Vol. 13 No. 4 (2024) · hlm. 936–947

DOI
10.11591/ijaas.v13.i4.pp936-947
ISSN
2722-2594, 2252-8814
Terbit
2024-12-01
Penerbit
Institute of Advanced Engineering and Science
Bahasa
eng
Lisensi
creativecommons.org/licenses/by-sa/4.0

Abstrak

An artificial lift is a technique for pumping fluids in the petroleum industry today. Most artificial lift that is used nowadays is an electrical submersible pump (ESP). ESP is very convenient and reliable for lifting production. It applies under offshore and onshore industries, where it has high displacement capacity and flexibility to handle various sizes and flow rates under different well conditions. Due to severe operating conditions, ESP may experience fatigue failure, an undesirable malfunction resulting in a shortened service life. Early failure detection on ESP is imperative to prevent a major failure in the pump and reduce the cost of the damage. This study provides an in-depth examination of condition monitoring and early failure detection, with a focus on mechanical and electrical failures. This paper begins with a description of the ESP working principle followed by an analysis of ESP fault and numerous ESP performance monitoring techniques, including the application of early detection. Finally, the authors summarize ESP’s failures, including detection methods for each failure. Besides, recommendations for future research to increase ESP’s lifetime are also discussed. This review revealed that the lifetime of existing ESP can be extended if extensive monitoring of ESP conditions and advanced fault detection methods are applied.

Jaringan kolaborasi para penulis

12 penulis · 33 tautan kepenulisan bersama · 14 lintas organisasi

Arahkan kursor atau ketuk sebuah nama untuk menyorot rekan penulisnya. Klik dua kali untuk membuka halaman penulis.

  • Universiti Teknikal Malaysia Melaka
  • Universiti Malaysia Terengganu
  • Universiti Malaysia Perlis
  • Universiti Teknologi MARA
  • Afiliasi tidak diketahui
  • Organisasi berbeda
  • Organisasi sama
  • Afiliasi tidak diketahui
  • Garis lebih tebal = lebih banyak artikel bersama · lingkaran lebih besar = lebih banyak artikel
Tampilkan sebagai tabel
Rekan penulisOrganisasiArtikel bersama
Shakir SaatUniversiti Teknikal Malaysia Melaka4
Yusmarnita binti YusopUniversiti Teknikal Malaysia Melaka4
Siti Huzaimah HusinUniversiti Teknikal Malaysia Melaka2
Ahmad Husni Mohd ShapriUniversiti Malaysia Perlis2
N. X. YinUniversiti Teknikal Malaysia Melaka1
Khairul Kamarudin HasanUniversiti Teknologi MARA1
Huzaimah HusinUniversiti Teknikal Malaysia Melaka1
Ahmed Al-HattamiAfiliasi tidak diketahui1

Afiliasi berasal dari OpenAlex; metadata OAI-PMH jurnal tidak memuatnya. Penulis tanpa ID OpenAlex dicocokkan berdasarkan nama, sehingga dua orang bisa tergabung atau satu orang bisa terpisah.

Sumber metadata: OAI-PMH (metadata jurnal) http://ijaas.iaescore.com/index.php/IJAAS/oai, pertama di-harvest 8 Nov 2026, terakhir terlihat 16 Nov 2026.
Metadata asli (oai_dc)
<oai_dc:dc xmlns="http://www.openarchives.org/OAI/2.0/" xmlns:dc="http://purl.org/dc/elements/1.1/" xmlns:oai_dc="http://www.openarchives.org/OAI/2.0/oai_dc/" xmlns:xsi="http://www.w3.org/2001/XMLSchema-instance" xsi:schemaLocation="http://www.openarchives.org/OAI/2.0/oai_dc/  http://www.openarchives.org/OAI/2.0/oai_dc.xsd">
	<dc:title xml:lang="en-US">Review on electrical submersible pump failures detection and monitoring system</dc:title>
	<dc:creator>Mohamad, Sharifah Nur Fatieha</dc:creator>
	<dc:creator>Afrizal, Nurafnida</dc:creator>
	<dc:creator>Daud, Muhammad Zalani</dc:creator>
	<dc:creator>Awal, Md Rabiul</dc:creator>
	<dc:description xml:lang="en-US">An artificial lift is a technique for pumping fluids in the petroleum industry today. Most artificial lift that is used nowadays is an electrical submersible pump (ESP). ESP is very convenient and reliable for lifting production. It applies under offshore and onshore industries, where it has high displacement capacity and flexibility to handle various sizes and flow rates under different well conditions. Due to severe operating conditions, ESP may experience fatigue failure, an undesirable malfunction resulting in a shortened service life. Early failure detection on ESP is imperative to prevent a major failure in the pump and reduce the cost of the damage. This study provides an in-depth examination of condition monitoring and early failure detection, with a focus on mechanical and electrical failures. This paper begins with a description of the ESP working principle followed by an analysis of ESP fault and numerous ESP performance monitoring techniques, including the application of early detection. Finally, the authors summarize ESP’s failures, including detection methods for each failure. Besides, recommendations for future research to increase ESP’s lifetime are also discussed. This review revealed that the lifetime of existing ESP can be extended if extensive monitoring of ESP conditions and advanced fault detection methods are applied.</dc:description>
	<dc:publisher xml:lang="en-US">Institute of Advanced Engineering and Science</dc:publisher>
	<dc:contributor xml:lang="en-US">Talent and Publication Enhancement Research Grant (TAPE-RG)</dc:contributor>
	<dc:contributor xml:lang="en-US">Vot Number:55329</dc:contributor>
	<dc:contributor xml:lang="en-US">Universiti Malaysia Terengganu.</dc:contributor>
	<dc:date>2024-12-01</dc:date>
	<dc:type>info:eu-repo/semantics/article</dc:type>
	<dc:type>info:eu-repo/semantics/publishedVersion</dc:type>
	<dc:type xml:lang="en-US"></dc:type>
	<dc:format>application/pdf</dc:format>
	<dc:identifier>https://ijaas.iaescore.com/index.php/IJAAS/article/view/21276</dc:identifier>
	<dc:identifier>10.11591/ijaas.v13.i4.pp936-947</dc:identifier>
	<dc:source xml:lang="en-US">International Journal of Advances in Applied Sciences; Vol 13, No 4: December 2024; 936-947</dc:source>
	<dc:source>2722-2594</dc:source>
	<dc:source>2252-8814</dc:source>
	<dc:source>10.11591/ijaas.v13.i4</dc:source>
	<dc:language>eng</dc:language>
	<dc:relation>https://ijaas.iaescore.com/index.php/IJAAS/article/view/21276/13192</dc:relation>
	<dc:rights xml:lang="en-US">Copyright (c) 2024 Institute of Advanced Engineering and Science (IAES)</dc:rights>
	<dc:rights xml:lang="en-US">http://creativecommons.org/licenses/by-sa/4.0</dc:rights>
</oai_dc:dc>