Melola Discovery

← Melola Discovery

Akses terbuka Jurnal SINTA 1

Netload-constrained Unit Commitment Considering Increasing Renewable Energy Penetration Levels: Impact of Generation Schedules and Operational Cost

International Journal of Applied Power Engineering (IJAPE) · Vol. 7 No. 1 (2018) · hlm. 87–98

DOI
10.11591/ijape.v7.i1.pp87-98
ISSN
2722-2624, 2252-8792
Terbit
2018-04-01
Penerbit
Institute of Advanced Engineering and Science
Bahasa
eng
Lisensi
creativecommons.org/licenses/by-sa/4.0

Abstrak

In the context of low carbon power systems, the penetration levels of Renewable Energy Sources (RES) are expected to increase dramatically. In this regard, this paper investigates the maximum RES penetration level constrained by net load while considering an inflexible Unit Commitment (UC) model. To solve the UC problem, an enhanced priority list (EPL) based method is developed. In the proposed method, the plants were activated sequentially based on the operational price. The system constraint violations were repeatedly corrected until all system constraints (such as net load and spinning reserves) were satisfied. The proposed EPL method was efficient to achieve a near optimal solution under high shares of RES. Furthermore, the research work investigates three different scenarios representing penetration levels of 10% solar-only, 14.5% wind-only and 27.5% mixture of both solar and wind. The impact of each penetration level on the system scheduling and operational cost were analyzed in detail. The analysis presented shows that a potential operational cost savings of 21.6 $/MW, 20 $/MW and 11.1 $/MW is feasible under each of the represented scenarios, respectively.

Jaringan kolaborasi para penulis

40 penulis · 107 tautan kepenulisan bersama · 54 lintas organisasi · menampilkan 40 yang paling banyak terhubung

Arahkan kursor atau ketuk sebuah nama untuk menyorot rekan penulisnya. Klik dua kali untuk membuka halaman penulis.

  • University of Technology Malaysia
  • Institut Teknologi PLN
  • Riau University
  • Politeknik Negeri Ujung Pandang
  • Ahmadu Bello University
  • Robert Gordon University
  • Jubail Industrial College
  • Organisasi lain
  • Afiliasi tidak diketahui
  • Organisasi berbeda
  • Organisasi sama
  • Afiliasi tidak diketahui
  • Garis lebih tebal = lebih banyak artikel bersama · lingkaran lebih besar = lebih banyak artikel
Tampilkan sebagai tabel
Rekan penulisOrganisasiArtikel bersama
Nurul Aini BaniUniversity of Technology Malaysia2
Z Abdul-MalekUniversity of Technology Malaysia2
Firdaus Muhammad‐SukkiRobert Gordon University2
Abdullahi Abubakar Mas’udJubail Industrial College2
Mohd Nabil MuhtazaruddinUniversity of Technology Malaysia2
Kamilia KamardinUniversity of Technology Malaysia2
Hamza AhmadTun Hussein Onn University of Malaysia2
Olatunji Obalowu MohammedUniversity of Technology Malaysia2
Adri SenenInstitut Teknologi PLN2
Azriyenni Azhari ZakriRiau University2
Zulkarnain Ahmad NoordenUniversity of Technology Malaysia2
Razman AyopUniversity of Technology Malaysia2
Chee Wei TanUniversity of Technology Malaysia2
Shahrin Md AyobUniversity of Technology Malaysia2
Hazlie MokhlisUniversity of Malaya2
Muhammad Ariff BaharudinUniversity of Technology Malaysia2
Makmur SainiPoliteknik Negeri Ujung Pandang1
Abdullah Asuhaimi Mohd ZinUniversity of Technology Malaysia1
A. R. SultanPoliteknik Negeri Ujung Pandang1
Rusdi NurPoliteknik Negeri Ujung Pandang1
Sajid Hussain QaziMehran University of Engineering & Technology Shaheed Zulfiqar Ali Bhutto Campus, Khairpur Mir's1
Sani SalisuAhmadu Bello University1
Mamunu MustaphaAfiliasi tidak diketahui1
Azriyenni AzriyenniAfiliasi tidak diketahui1
Ginas AlvianingsihUniversity of Technology Malaysia1
Haslenda binti HashimUniversity of Technology Malaysia1
Hasna Satya DiniInstitut Teknologi PLN1
Eko Supriyanto‬University of Technology Malaysia1
Dwi AnggainiInstitut Teknologi PLN1
Syukri DarmawanRiau University1
Sandy AhmadRiau University1
Jafaru UsmanUniversity of Maiduguri1
Sani SalisuAhmadu Bello University1
Ahsanullah MemonMehran University of Engineering and Technology1
Saddam HussainUniversity of Technology Malaysia1

Afiliasi berasal dari OpenAlex; metadata OAI-PMH jurnal tidak memuatnya. Penulis tanpa ID OpenAlex dicocokkan berdasarkan nama, sehingga dua orang bisa tergabung atau satu orang bisa terpisah.

Sumber metadata: OAI-PMH (metadata jurnal) http://ijape.iaescore.com/index.php/IJAPE/oai, pertama di-harvest 8 Nov 2026, terakhir terlihat 16 Nov 2026.
Metadata asli (oai_dc)
<oai_dc:dc xmlns="http://www.openarchives.org/OAI/2.0/" xmlns:dc="http://purl.org/dc/elements/1.1/" xmlns:oai_dc="http://www.openarchives.org/OAI/2.0/oai_dc/" xmlns:xsi="http://www.w3.org/2001/XMLSchema-instance" xsi:schemaLocation="http://www.openarchives.org/OAI/2.0/oai_dc/  http://www.openarchives.org/OAI/2.0/oai_dc.xsd">
	<dc:title xml:lang="en-US">Netload-constrained Unit Commitment Considering Increasing Renewable Energy Penetration Levels: Impact of Generation Schedules and Operational Cost</dc:title>
	<dc:creator>Abujarad, Saleh Y.</dc:creator>
	<dc:creator>Mustafa, M. W.</dc:creator>
	<dc:creator>Jamian, J. J.</dc:creator>
	<dc:creator>Abdilahi, Abdirahman M.</dc:creator>
	<dc:creator>Zareen, N.</dc:creator>
	<dc:description xml:lang="en-US">In the context of low carbon power systems, the penetration levels of Renewable Energy Sources (RES) are expected to increase dramatically. In this regard, this paper investigates the maximum RES penetration level constrained by net load while considering an inflexible Unit Commitment (UC) model. To solve the UC problem, an enhanced priority list (EPL) based method is developed. In the proposed method, the plants were activated sequentially based on the operational price. The system constraint violations were repeatedly corrected until all system constraints (such as net load and spinning reserves) were satisfied. The proposed EPL method was efficient to achieve a near optimal solution under high shares of RES. Furthermore, the research work investigates three different scenarios representing penetration levels of 10% solar-only, 14.5% wind-only and 27.5% mixture of both solar and wind. The impact of each penetration level on the system scheduling and operational cost were analyzed in detail. The analysis presented shows that a potential operational cost savings of 21.6 $/MW, 20 $/MW and 11.1 $/MW is feasible under each of the represented scenarios, respectively.</dc:description>
	<dc:publisher xml:lang="en-US">Institute of Advanced Engineering and Science</dc:publisher>
	<dc:contributor xml:lang="en-US"></dc:contributor>
	<dc:date>2018-04-01</dc:date>
	<dc:type>info:eu-repo/semantics/article</dc:type>
	<dc:type>info:eu-repo/semantics/publishedVersion</dc:type>
	<dc:type xml:lang="en-US"></dc:type>
	<dc:format>application/pdf</dc:format>
	<dc:identifier>https://ijape.iaescore.com/index.php/IJAPE/article/view/10856</dc:identifier>
	<dc:identifier>10.11591/ijape.v7.i1.pp87-98</dc:identifier>
	<dc:source xml:lang="en-US">International Journal of Applied Power Engineering (IJAPE); Vol 7, No 1: April 2018; 87-98</dc:source>
	<dc:source>2722-2624</dc:source>
	<dc:source>2252-8792</dc:source>
	<dc:source>10.11591/ijape.v7.i1</dc:source>
	<dc:language>eng</dc:language>
	<dc:relation>https://ijape.iaescore.com/index.php/IJAPE/article/view/10856/12112</dc:relation>
	<dc:rights xml:lang="en-US">Copyright (c) 2021 Institute of Advanced Engineering and Science</dc:rights>
	<dc:rights xml:lang="en-US">http://creativecommons.org/licenses/by-sa/4.0</dc:rights>
</oai_dc:dc>