Melola Discovery

← Melola Discovery

Akses terbuka Jurnal SINTA 1

Multicarrier SPWM Control Techniques for Three Phase Eleven Level Diode Clamped Multilevel Inverter and Hybrid Inverter with Reduced Number of Components

International Journal of Applied Power Engineering (IJAPE) · Vol. 7 No. 3 (2018) · hlm. 251–263

DOI
10.11591/ijape.v7.i3.pp251-263
ISSN
2722-2624, 2252-8792
Terbit
2018-12-01
Penerbit
Institute of Advanced Engineering and Science
Bahasa
eng
Lisensi
creativecommons.org/licenses/by-sa/4.0

Abstrak

A comparative analysis of three phase eleven level diode clamped multilevel inverter (DCMLI) and hybrid inverter is performed in this paper in which the later requires fewer carrier signals, less number of devices and gate drive circuits. The performance is evaluated using phase disposition (PD), alternate phase opposition disposition (APOD) and carrier overlapping (CO) sinusoidal pulse width modulation (SPWM) methods. The hybrid multilevel inverter has superior features over diode clamped multilevel inverters and is more efficient since the positive levels of the inverter that are generated by high frequency switches (level generation part), are reversed by low frequency switches (polarity generation part) when the voltage polarity is required to be changed for negative polarity. Therefore, the overall cost and complexity of the hybrid inverter are greatly reduced particularly for higher inverter output voltage levels. Simulation is performed for three phase eleven level diode clamped multilevel inverter and hybrid multilevel inverter using MATLAB/Simulink for induction motor load and the total harmonic distortion is evaluated at different load torques.

Jaringan kolaborasi para penulis

9 penulis · 9 tautan kepenulisan bersama · 1 lintas organisasi

Arahkan kursor atau ketuk sebuah nama untuk menyorot rekan penulisnya. Klik dua kali untuk membuka halaman penulis.

  • Osmania University
  • Jawaharlal Nehru Technological University Anantapur
  • Afiliasi tidak diketahui
  • Organisasi berbeda
  • Organisasi sama
  • Afiliasi tidak diketahui
  • Garis lebih tebal = lebih banyak artikel bersama · lingkaran lebih besar = lebih banyak artikel
Tampilkan sebagai tabel
Rekan penulisOrganisasiArtikel bersama
Ravikumar BhukyaOsmania University3
Ravi Kumar BhukyaAfiliasi tidak diketahui1
V. ChandraOsmania University1
Satish KumarAfiliasi tidak diketahui1
M. SushamaJawaharlal Nehru Technological University Anantapur1
Ch. Lokeshwar ReddyAfiliasi tidak diketahui1
Bogimi SirishaOsmania University1

Afiliasi berasal dari OpenAlex; metadata OAI-PMH jurnal tidak memuatnya. Penulis tanpa ID OpenAlex dicocokkan berdasarkan nama, sehingga dua orang bisa tergabung atau satu orang bisa terpisah.

Sumber metadata: OAI-PMH (metadata jurnal) http://ijape.iaescore.com/index.php/IJAPE/oai, pertama di-harvest 8 Nov 2026, terakhir terlihat 22 Nov 2026.
Metadata asli (oai_dc)
<oai_dc:dc xmlns="http://www.openarchives.org/OAI/2.0/" xmlns:dc="http://purl.org/dc/elements/1.1/" xmlns:oai_dc="http://www.openarchives.org/OAI/2.0/oai_dc/" xmlns:xsi="http://www.w3.org/2001/XMLSchema-instance" xsi:schemaLocation="http://www.openarchives.org/OAI/2.0/oai_dc/  http://www.openarchives.org/OAI/2.0/oai_dc.xsd">
	<dc:title xml:lang="en-US">Multicarrier SPWM Control Techniques for Three Phase Eleven Level Diode Clamped Multilevel Inverter and Hybrid Inverter with Reduced Number of Components</dc:title>
	<dc:creator>Susheela, N.</dc:creator>
	<dc:creator>Kumar, P. Satish</dc:creator>
	<dc:description xml:lang="en-US">A comparative analysis of three phase eleven level diode clamped multilevel inverter (DCMLI) and hybrid inverter is performed in this paper in which the later requires fewer carrier signals, less number of devices and gate drive circuits. The performance is evaluated using phase disposition (PD), alternate phase opposition disposition (APOD) and carrier overlapping (CO) sinusoidal pulse width modulation (SPWM) methods. The hybrid multilevel inverter has superior features over diode clamped multilevel inverters and is more efficient since the positive levels of the inverter that are generated  by high frequency switches (level generation part), are reversed by low frequency switches (polarity generation part) when the voltage polarity is required to be changed for negative polarity. Therefore, the overall cost and complexity of the hybrid inverter are greatly reduced particularly for higher inverter output voltage levels. Simulation is performed for three phase eleven level diode clamped multilevel inverter and hybrid multilevel inverter using MATLAB/Simulink for induction motor load and the total harmonic distortion is evaluated at different load torques.</dc:description>
	<dc:publisher xml:lang="en-US">Institute of Advanced Engineering and Science</dc:publisher>
	<dc:contributor xml:lang="en-US"></dc:contributor>
	<dc:date>2018-12-01</dc:date>
	<dc:type>info:eu-repo/semantics/article</dc:type>
	<dc:type>info:eu-repo/semantics/publishedVersion</dc:type>
	<dc:type xml:lang="en-US"></dc:type>
	<dc:format>application/pdf</dc:format>
	<dc:identifier>https://ijape.iaescore.com/index.php/IJAPE/article/view/14924</dc:identifier>
	<dc:identifier>10.11591/ijape.v7.i3.pp251-263</dc:identifier>
	<dc:source xml:lang="en-US">International Journal of Applied Power Engineering (IJAPE); Vol 7, No 3: December 2018; 251-263</dc:source>
	<dc:source>2722-2624</dc:source>
	<dc:source>2252-8792</dc:source>
	<dc:source>10.11591/ijape.v7.i3</dc:source>
	<dc:language>eng</dc:language>
	<dc:relation>https://ijape.iaescore.com/index.php/IJAPE/article/view/14924/12154</dc:relation>
	<dc:rights xml:lang="en-US">Copyright (c) 2021 Institute of Advanced Engineering and Science</dc:rights>
	<dc:rights xml:lang="en-US">http://creativecommons.org/licenses/by-sa/4.0</dc:rights>
</oai_dc:dc>