Melola Discovery

← Melola Discovery

Akses terbuka Jurnal SINTA 1

Power quality improvement and analysis of interconnected bus system with PMU using VSM-STATCOM

International Journal of Applied Power Engineering (IJAPE) · Vol. 11 No. 1 (2022) · hlm. 52–61

DOI
10.11591/ijape.v11.i1.pp52-61
ISSN
2722-2624, 2252-8792
Terbit
2022-03-01
Penerbit
Institute of Advanced Engineering and Science
Bahasa
eng
Lisensi
creativecommons.org/licenses/by-sa/4.0

Abstrak

The traditional static synchronous compensator (STATCOM) present in the power grid to compensate instability problem will not be not able to maintain stability of the system due to fluctuations in point of common coupling (PCC) voltage and frequency variation that may result in poor synchronization of the grid. The solution for this is the improvement in conventional STATCOM to virtual synchronous machine–static synchronous compensator (VSM-STATCOM). In this paper an interconnected IEEE-14 bus system is considered for analysis with VSM-STATCOM for improvement in voltage profile on weakest bus of the system. In order to find the weakest bus, load flow analysis is carried out on the bus system using Newton Rapson method. A VSM-STATCOM is connected at that weakest bus in synchronization to the grid injecting reactive power. For the analysis a fault is introduced on any of the line and voltage profile of the weakest bus is observed with and without VSM-STATCOM. The VSM-STATCOM is also compared to a conventional control STATCOM which has no inertia module. A comparative analysis is carrier out with parameters of voltage magnitude and frequency of the weak bus taken into consideration. The magnitude and frequency parameters of conventional STATCOM and VSM-STATCOM are measured using phasor measurement units. The model is designed using MATLAB Simulink power systems library block sets with graphical user interface (GUI) environment.

Kata kunci

Jaringan kolaborasi para penulis

5 penulis · 6 tautan kepenulisan bersama · 1 lintas organisasi

Arahkan kursor atau ketuk sebuah nama untuk menyorot rekan penulisnya. Klik dua kali untuk membuka halaman penulis.

  • Koneru Lakshmaiah Education Foundation
  • Deccan College Post Graduate and Research Institute
  • Afiliasi tidak diketahui
  • Organisasi berbeda
  • Organisasi sama
  • Afiliasi tidak diketahui
  • Garis lebih tebal = lebih banyak artikel bersama · lingkaran lebih besar = lebih banyak artikel
Tampilkan sebagai tabel
Rekan penulisOrganisasiArtikel bersama
S. V. N. L. LalithaKoneru Lakshmaiah Education Foundation2
Swathi KarikeKoneru Lakshmaiah Education Foundation1
Kuthuri Narasimha RajuKoneru Lakshmaiah Education Foundation1

Afiliasi berasal dari OpenAlex; metadata OAI-PMH jurnal tidak memuatnya. Penulis tanpa ID OpenAlex dicocokkan berdasarkan nama, sehingga dua orang bisa tergabung atau satu orang bisa terpisah.

Sumber metadata: OAI-PMH (metadata jurnal) http://ijape.iaescore.com/index.php/IJAPE/oai, pertama di-harvest 8 Nov 2026, terakhir terlihat 16 Nov 2026.
Metadata asli (oai_dc)
<oai_dc:dc xmlns="http://www.openarchives.org/OAI/2.0/" xmlns:dc="http://purl.org/dc/elements/1.1/" xmlns:oai_dc="http://www.openarchives.org/OAI/2.0/oai_dc/" xmlns:xsi="http://www.w3.org/2001/XMLSchema-instance" xsi:schemaLocation="http://www.openarchives.org/OAI/2.0/oai_dc/  http://www.openarchives.org/OAI/2.0/oai_dc.xsd">
	<dc:title xml:lang="en-US">Power quality improvement and analysis of interconnected bus system with PMU using VSM-STATCOM</dc:title>
	<dc:creator>Kabra, Preeti Nitin</dc:creator>
	<dc:creator>Donepudi, Sudha Rani</dc:creator>
	<dc:subject xml:lang="en-US">graphical user interface; non-conventional energy sources; phasor measurement unit; synchrophasors; virtual synchronous machine–static synchronous compensator</dc:subject>
	<dc:description xml:lang="en-US">The traditional static synchronous compensator (STATCOM) present in the power grid to compensate instability problem will not be not able to maintain stability of the system due to fluctuations in point of common coupling (PCC) voltage and frequency variation that may result in poor synchronization of the grid. The solution for this is the improvement in conventional STATCOM to virtual synchronous machine–static synchronous compensator (VSM-STATCOM). In this paper an interconnected IEEE-14 bus system is considered for analysis with VSM-STATCOM for improvement in voltage profile on weakest bus of the system. In order to find the weakest bus, load flow analysis is carried out on the bus system using Newton Rapson method. A VSM-STATCOM is connected at that weakest bus in synchronization to the grid injecting reactive power. For the analysis a fault is introduced on any of the line and voltage profile of the weakest bus is observed with and without VSM-STATCOM. The VSM-STATCOM is also compared to a conventional control STATCOM which has no inertia module. A comparative analysis is carrier out with parameters of voltage magnitude and frequency of the weak bus taken into consideration. The magnitude and frequency parameters of conventional STATCOM and VSM-STATCOM are measured using phasor measurement units. The model is designed using MATLAB Simulink power systems library block sets with graphical user interface (GUI) environment.</dc:description>
	<dc:publisher xml:lang="en-US">Institute of Advanced Engineering and Science</dc:publisher>
	<dc:contributor xml:lang="en-US"></dc:contributor>
	<dc:date>2022-03-01</dc:date>
	<dc:type>info:eu-repo/semantics/article</dc:type>
	<dc:type>info:eu-repo/semantics/publishedVersion</dc:type>
	<dc:type xml:lang="en-US"></dc:type>
	<dc:format>application/pdf</dc:format>
	<dc:identifier>https://ijape.iaescore.com/index.php/IJAPE/article/view/20456</dc:identifier>
	<dc:identifier>10.11591/ijape.v11.i1.pp52-61</dc:identifier>
	<dc:source xml:lang="en-US">International Journal of Applied Power Engineering (IJAPE); Vol 11, No 1: March 2022; 52-61</dc:source>
	<dc:source>2722-2624</dc:source>
	<dc:source>2252-8792</dc:source>
	<dc:source>10.11591/ijape.v11.i1</dc:source>
	<dc:language>eng</dc:language>
	<dc:relation>https://ijape.iaescore.com/index.php/IJAPE/article/view/20456/12990</dc:relation>
	<dc:rights xml:lang="en-US">Copyright (c) 2022 Preeti Nitin Kabra</dc:rights>
	<dc:rights xml:lang="en-US">http://creativecommons.org/licenses/by-sa/4.0</dc:rights>
</oai_dc:dc>