Melola Discovery

← Melola Discovery

Akses terbuka Jurnal SINTA 1

Voltage Stability Based Formation of Voltage Control Areas Considering Impact of Contingencies

International Journal of Applied Power Engineering (IJAPE) · Vol. 1 No. 3 (2012) · hlm. 115–122

DOI
10.11591/ijape.v1.i3.pp115-122
ISSN
2722-2624, 2252-8792
Terbit
2012-12-01
Penerbit
Institute of Advanced Engineering and Science
Bahasa
eng
Lisensi
creativecommons.org/licenses/by-sa/4.0

Abstrak

Voltage instability has been considered as a major threat to power system networks since last three decades. Frequent incidences of grid failures caused by voltage instability have been observed in different parts of the world. Fast voltage stability assessment of power system may be done by formation of voltage control areas, clubbing group of buses in geographically compact region having similar voltage instability problem. This paper presents a new approach for formation of voltage control areas (VCAs) based on sensitivity of reactive power generations with respect to reactive power demands, together with bus voltage variations under voltage stability based critical contingencies. The load buses in geographically compact region showing similar sensitivity of reactive power demand to reactive generations have been clubbed together to form voltage control areas. Since, voltage control areas formed should remain valid under change in operating conditions and network topology, the areas formed based on reactive power sensitivitieshave been modified considering voltage variations at different loadings points under voltage stability based critical contingencies. Voltage stability based Critical contingencies have been selected based on maximum loadability criterion. Case studies have been performed on IEEE 14-bus system. Simulation results performed on IEEE 14-bus system validate VCAs formed even under change in network topology caused by line outages and change in operating conditions caused by variations in real and reactive power demands. The VCAs formed by proposed method have been compared with VCAs formed by few existing approaches. The superiority of proposed approach of voltage control areas formation over few existing approaches has been established on the test system considered.

Kata kunci

Jaringan kolaborasi para penulis

5 penulis · 7 tautan kepenulisan bersama

Arahkan kursor atau ketuk sebuah nama untuk menyorot rekan penulisnya. Klik dua kali untuk membuka halaman penulis.

  • Afiliasi tidak diketahui
  • Organisasi berbeda
  • Organisasi sama
  • Afiliasi tidak diketahui
  • Garis lebih tebal = lebih banyak artikel bersama · lingkaran lebih besar = lebih banyak artikel
Tampilkan sebagai tabel
Rekan penulisOrganisasiArtikel bersama
Brijesh SinghAfiliasi tidak diketahui1
D.K. TantiAfiliasi tidak diketahui1
O.N. MehrotraAfiliasi tidak diketahui1

Afiliasi berasal dari OpenAlex; metadata OAI-PMH jurnal tidak memuatnya. Penulis tanpa ID OpenAlex dicocokkan berdasarkan nama, sehingga dua orang bisa tergabung atau satu orang bisa terpisah.

Sumber metadata: OAI-PMH (metadata jurnal) http://ijape.iaescore.com/index.php/IJAPE/oai, pertama di-harvest 8 Nov 2026, terakhir terlihat 22 Nov 2026.
Metadata asli (oai_dc)
<oai_dc:dc xmlns="http://www.openarchives.org/OAI/2.0/" xmlns:dc="http://purl.org/dc/elements/1.1/" xmlns:oai_dc="http://www.openarchives.org/OAI/2.0/oai_dc/" xmlns:xsi="http://www.w3.org/2001/XMLSchema-instance" xsi:schemaLocation="http://www.openarchives.org/OAI/2.0/oai_dc/  http://www.openarchives.org/OAI/2.0/oai_dc.xsd">
	<dc:title xml:lang="en-US">Voltage Stability Based Formation of Voltage Control Areas Considering Impact of Contingencies</dc:title>
	<dc:creator>Martolia, Tarun</dc:creator>
	<dc:creator>Verma, M.K.</dc:creator>
	<dc:subject xml:lang="en-US">Voltage control area,  reactive power sensitivity, contingencies, maximum loadability, voltage stability</dc:subject>
	<dc:description xml:lang="en-US">Voltage instability has been considered as a major threat to power system networks since last three decades. Frequent incidences of grid failures caused by voltage instability have been observed in different parts of the world. Fast voltage stability assessment of power system may be done by formation of voltage control areas, clubbing group of buses in geographically compact region having similar voltage instability problem. This paper presents a new approach for formation of voltage control areas (VCAs) based on sensitivity of reactive power generations with respect to reactive power demands, together with bus voltage variations under voltage stability based critical contingencies. The load buses in geographically compact region showing similar sensitivity of reactive power demand to reactive generations have been clubbed together to form voltage control areas. Since, voltage control areas formed should remain valid under change in operating conditions and network topology, the areas formed based on reactive power sensitivitieshave been modified considering voltage variations at different loadings points under voltage stability based critical contingencies. Voltage stability based Critical contingencies have been selected based on maximum loadability criterion. Case studies have been performed on IEEE 14-bus system. Simulation results performed on IEEE 14-bus system validate VCAs formed even under change in network topology caused by line outages and change in operating conditions caused by variations in real and reactive power demands. The VCAs formed by proposed method have been compared with VCAs formed by few existing approaches. The superiority of proposed approach of voltage control areas formation over few existing approaches has been established on the test system considered.</dc:description>
	<dc:publisher xml:lang="en-US">Institute of Advanced Engineering and Science</dc:publisher>
	<dc:contributor xml:lang="en-US"></dc:contributor>
	<dc:date>2012-12-01</dc:date>
	<dc:type>info:eu-repo/semantics/article</dc:type>
	<dc:type>info:eu-repo/semantics/publishedVersion</dc:type>
	<dc:type xml:lang="en-US"></dc:type>
	<dc:format>application/pdf</dc:format>
	<dc:identifier>https://ijape.iaescore.com/index.php/IJAPE/article/view/1291</dc:identifier>
	<dc:identifier>10.11591/ijape.v1.i3.pp115-122</dc:identifier>
	<dc:source xml:lang="en-US">International Journal of Applied Power Engineering (IJAPE); Vol 1, No 3: December 2012; 115-122</dc:source>
	<dc:source>2722-2624</dc:source>
	<dc:source>2252-8792</dc:source>
	<dc:source>10.11591/ijape.v1.i3</dc:source>
	<dc:language>eng</dc:language>
	<dc:relation>https://ijape.iaescore.com/index.php/IJAPE/article/view/1291/735</dc:relation>
	<dc:rights xml:lang="en-US">Copyright (c) 2021 Institute of Advanced Engineering and Science</dc:rights>
	<dc:rights xml:lang="en-US">http://creativecommons.org/licenses/by-sa/4.0</dc:rights>