Melola Discovery

← Melola Discovery

Akses terbuka Jurnal SINTA 1

Investigation of 22 kV silane cure TR-EPR cable

International Journal of Applied Power Engineering (IJAPE) · Vol. 10 No. 1 (2021) · hlm. 41–47

DOI
10.11591/ijape.v10.i1.pp41-47
ISSN
2722-2624, 2252-8792
Terbit
2021-03-01
Penerbit
Institute of Advanced Engineering and Science
Bahasa
eng
Lisensi
creativecommons.org/licenses/by-sa/4.0

Abstrak

EPR-insulated cables for distribution power network are not commonly used in Australia. This is due to the higher DDF of common EPR cables when compared with XLPE that contributes to the power loss and economics in transmitting electricity. This led to the development of EPR called TR-EPR with significantly lower DDF and uses silane curing process to address concerns about cost-effectiveness. The thermal behavior of low DDF silane cure TR-EPR is investigated for 30 months of exposure to the maximum operating temperature of material. The physical changes in the samples throughout the long-term aging are examined to create an opportunity to model the expected life cycle of TR-EPR cable under thermal stress. The cross-linking characteristics of TR-EPR cable are also examined by ambient curing that simulates the storage condition for unused cable and by cable heating process that simulates the condition when the cable is energized. The results are tabulated for a better understanding of the time for the material to cross-link at various conditions. The improved partial discharge values after cross-linking are also presented.

Jaringan kolaborasi para penulis

6 penulis · 9 tautan kepenulisan bersama · 3 lintas organisasi

Arahkan kursor atau ketuk sebuah nama untuk menyorot rekan penulisnya. Klik dua kali untuk membuka halaman penulis.

  • Victoria University
  • University of Engineering and Technology Lahore
  • University of Georgia
  • Afiliasi tidak diketahui
  • Organisasi berbeda
  • Organisasi sama
  • Afiliasi tidak diketahui
  • Garis lebih tebal = lebih banyak artikel bersama · lingkaran lebih besar = lebih banyak artikel
Tampilkan sebagai tabel
Rekan penulisOrganisasiArtikel bersama
Faizan DastgeerUniversity of Engineering and Technology Lahore1
Ayisha NaeemAfiliasi tidak diketahui1
Faraz AhmadUniversity of Georgia1

Afiliasi berasal dari OpenAlex; metadata OAI-PMH jurnal tidak memuatnya. Penulis tanpa ID OpenAlex dicocokkan berdasarkan nama, sehingga dua orang bisa tergabung atau satu orang bisa terpisah.

Sumber metadata: OAI-PMH (metadata jurnal) http://ijape.iaescore.com/index.php/IJAPE/oai, pertama di-harvest 8 Nov 2026, terakhir terlihat 22 Nov 2026.
Metadata asli (oai_dc)
<oai_dc:dc xmlns="http://www.openarchives.org/OAI/2.0/" xmlns:dc="http://purl.org/dc/elements/1.1/" xmlns:oai_dc="http://www.openarchives.org/OAI/2.0/oai_dc/" xmlns:xsi="http://www.w3.org/2001/XMLSchema-instance" xsi:schemaLocation="http://www.openarchives.org/OAI/2.0/oai_dc/  http://www.openarchives.org/OAI/2.0/oai_dc.xsd">
	<dc:title xml:lang="en-US">Investigation of 22 kV silane cure TR-EPR cable</dc:title>
	<dc:creator>Agustin, Fernando</dc:creator>
	<dc:creator>Kalam, Akhtar</dc:creator>
	<dc:creator>Zayegh, Aladin</dc:creator>
	<dc:description xml:lang="en-US">EPR-insulated cables for distribution power network are not commonly used in Australia. This is due to the higher DDF of common EPR cables when compared with XLPE that contributes to the power loss and economics in transmitting electricity. This led to the development of EPR called TR-EPR with significantly lower DDF and uses silane curing process to address concerns about cost-effectiveness. The thermal behavior of low DDF silane cure TR-EPR is investigated for 30 months of exposure to the maximum operating temperature of material. The physical changes in the samples throughout the long-term aging are examined to create an opportunity to model the expected life cycle of TR-EPR cable under thermal stress. The cross-linking characteristics of TR-EPR cable are also examined by ambient curing that simulates the storage condition for unused cable and by cable heating process that simulates the condition when the cable is energized. The results are tabulated for a better understanding of the time for the material to cross-link at various conditions. The improved partial discharge values after cross-linking are also presented.</dc:description>
	<dc:publisher xml:lang="en-US">Institute of Advanced Engineering and Science</dc:publisher>
	<dc:contributor xml:lang="en-US"></dc:contributor>
	<dc:date>2021-03-01</dc:date>
	<dc:type>info:eu-repo/semantics/article</dc:type>
	<dc:type>info:eu-repo/semantics/publishedVersion</dc:type>
	<dc:type xml:lang="en-US"></dc:type>
	<dc:format>application/pdf</dc:format>
	<dc:identifier>https://ijape.iaescore.com/index.php/IJAPE/article/view/20258</dc:identifier>
	<dc:identifier>10.11591/ijape.v10.i1.pp41-47</dc:identifier>
	<dc:source xml:lang="en-US">International Journal of Applied Power Engineering (IJAPE); Vol 10, No 1: March 2021; 41-47</dc:source>
	<dc:source>2722-2624</dc:source>
	<dc:source>2252-8792</dc:source>
	<dc:source>10.11591/ijape.v10.i1</dc:source>
	<dc:language>eng</dc:language>
	<dc:relation>https://ijape.iaescore.com/index.php/IJAPE/article/view/20258/12920</dc:relation>
	<dc:rights xml:lang="en-US">Copyright (c) 2021 Institute of Advanced Engineering and Science</dc:rights>
	<dc:rights xml:lang="en-US">http://creativecommons.org/licenses/by-sa/4.0</dc:rights>
</oai_dc:dc>