Akses terbuka
Jurnal
SINTA 1
High impedance fault discrimination in microgrid power system using stacking ensemble approach
International Journal of Applied Power Engineering (IJAPE) · Vol. 15 No. 1 (2026) · hlm. 98–109
ISSN 2722-2624, 2252-8792
Terbit 2026-03-01
Penerbit Institute of Advanced Engineering and Science
Bahasa eng
Abstrak
High impedance (HI) faults in microgrid (MG) power systems are non-linear, intermittent, and have low fault current magnitudes, making them challenging to detect by typical protective systems. Consequently, it is imperative to implement a sophisticated protection system that is dependent on the precision of fault detection. In this study, a stacking ensemble classifier (SEC) is proposed to discriminate HI fault from other transients within a photovoltaic (PV) generated MG power system. The MG model is simulated with the introduction of faults and transients. The features of data set from event signals are generated using the discrete wavelet transform (DWT) technique. The dataset is used to train the individual classifiers (Naïve Bayes (NB), decision tree J48 (DTJ), and K-nearest neighbors (KNN)) at initial and meta learner in the final stage of SEC. The SEC outperforms other classification methods with respect to accuracy of classification, rate of success in detecting HI fault, and performance measures. The outcomes of the classification study conducted under standard test conditions (STC) of solar PV and the noisy environment of event signals clearly demonstrate that the SEC is more dependable and performs better than the individual base classification approaches.
Jaringan kolaborasi para penulis
11 penulis ·
30 tautan kepenulisan bersama
· 14 lintas organisasi
Arahkan kursor atau ketuk sebuah nama untuk menyorot rekan penulisnya. Klik dua kali untuk membuka halaman penulis.
New Horizon College of Engineering Sri Ramakrishna Engineering College KIIT University PSG INSTITUTE OF TECHNOLOGY AND APPLIED RESEARCH Dr. N.G.P. Institute of Technology SRM Institute of Science and Technology Afiliasi tidak diketahui
Organisasi berbeda
Organisasi sama
Afiliasi tidak diketahui
Garis lebih tebal = lebih banyak artikel bersama · lingkaran lebih besar = lebih banyak artikel
Tampilkan sebagai tabel
Afiliasi berasal dari OpenAlex; metadata OAI-PMH jurnal tidak memuatnya. Penulis tanpa ID OpenAlex dicocokkan berdasarkan nama, sehingga dua orang bisa tergabung atau satu orang bisa terpisah.
Sumber metadata: OAI-PMH (metadata jurnal) http://ijape.iaescore.com/index.php/IJAPE/oai, pertama di-harvest 8 Nov 2026, terakhir terlihat 16 Nov 2026.
Metadata asli (oai_dc)
<oai_dc:dc xmlns="http://www.openarchives.org/OAI/2.0/" xmlns:dc="http://purl.org/dc/elements/1.1/" xmlns:oai_dc="http://www.openarchives.org/OAI/2.0/oai_dc/" xmlns:xsi="http://www.w3.org/2001/XMLSchema-instance" xsi:schemaLocation="http://www.openarchives.org/OAI/2.0/oai_dc/ http://www.openarchives.org/OAI/2.0/oai_dc.xsd">
<dc:title xml:lang="en-US">High impedance fault discrimination in microgrid power system using stacking ensemble approach</dc:title>
<dc:creator>Vinayagam, Arangarajan</dc:creator>
<dc:creator>Mohandas, Raman</dc:creator>
<dc:creator>Chindamani, Meyyappan</dc:creator>
<dc:creator>Sujatha, Bhadravathi Gavirangapa</dc:creator>
<dc:creator>Mishra, Soumya</dc:creator>
<dc:creator>Sundaramurthy, Arivoli</dc:creator>
<dc:subject xml:lang="en-US">decision tree; discrete wavelet transform; high impedance fault; microgrid; photovoltaic; stacking ensemble classifier</dc:subject>
<dc:description xml:lang="en-US">High impedance (HI) faults in microgrid (MG) power systems are non-linear, intermittent, and have low fault current magnitudes, making them challenging to detect by typical protective systems. Consequently, it is imperative to implement a sophisticated protection system that is dependent on the precision of fault detection. In this study, a stacking ensemble classifier (SEC) is proposed to discriminate HI fault from other transients within a photovoltaic (PV) generated MG power system. The MG model is simulated with the introduction of faults and transients. The features of data set from event signals are generated using the discrete wavelet transform (DWT) technique. The dataset is used to train the individual classifiers (Naïve Bayes (NB), decision tree J48 (DTJ), and K-nearest neighbors (KNN)) at initial and meta learner in the final stage of SEC. The SEC outperforms other classification methods with respect to accuracy of classification, rate of success in detecting HI fault, and performance measures. The outcomes of the classification study conducted under standard test conditions (STC) of solar PV and the noisy environment of event signals clearly demonstrate that the SEC is more dependable and performs better than the individual base classification approaches.</dc:description>
<dc:publisher xml:lang="en-US">Institute of Advanced Engineering and Science</dc:publisher>
<dc:contributor xml:lang="en-US"></dc:contributor>
<dc:date>2026-03-01</dc:date>
<dc:type>info:eu-repo/semantics/article</dc:type>
<dc:type>info:eu-repo/semantics/publishedVersion</dc:type>
<dc:type xml:lang="en-US"></dc:type>
<dc:format>application/pdf</dc:format>
<dc:identifier>https://ijape.iaescore.com/index.php/IJAPE/article/view/21855</dc:identifier>
<dc:identifier>10.11591/ijape.v15.i1.pp98-109</dc:identifier>
<dc:source xml:lang="en-US">International Journal of Applied Power Engineering (IJAPE); Vol 15, No 1: March 2026; 98-109</dc:source>
<dc:source>2722-2624</dc:source>
<dc:source>2252-8792</dc:source>
<dc:source>10.11591/ijape.v15.i1</dc:source>
<dc:language>eng</dc:language>
<dc:relation>https://ijape.iaescore.com/index.php/IJAPE/article/view/21855/13401</dc:relation>
<dc:relation>https://ijape.iaescore.com/index.php/IJAPE/article/downloadSuppFile/21855/3155</dc:relation>
<dc:rights xml:lang="en-US">Copyright (c) 2026 Arangarajan Vinayagam, Raman Mohandas, Meyyappan Chindamani, Bhadravathi Gavirangapa Sujatha, Soumya Mishra, Arivoli Sundaramurthy</dc:rights>
<dc:rights xml:lang="en-US">http://creativecommons.org/licenses/by-sa/4.0</dc:rights>
</oai_dc:dc>
Sitasi dan pengindeksan
Jumlah menurut tiap indeks pada 13 Nov 2026; setiap indeks menghitung sitasi dengan cara berbeda.
OpenAlex juga mencatat karya ini di: crossref.
Sitasi artikel ini
APA 7
Vinayagam, A., Mohandas, R., Chindamani, M., Sujatha, B. G., Mishra, S., & Sundaramurthy, A. (2026). High impedance fault discrimination in microgrid power system using stacking ensemble approach. International Journal of Applied Power Engineering (IJAPE), 15(1), 98–109. https://doi.org/10.11591/ijape.v15.i1.pp98-109
Salin
IEEE
A. Vinayagam, R. Mohandas, M. Chindamani, B. G. Sujatha, S. Mishra, and A. Sundaramurthy, “High impedance fault discrimination in microgrid power system using stacking ensemble approach,” International Journal of Applied Power Engineering (IJAPE), vol. 15, no. 1, pp. 98–109, 2026, doi: 10.11591/ijape.v15.i1.pp98-109.
Salin
Dibuat dari metadata jurnal; periksa nama penulis sebelum dipakai.