Melola Discovery

← Melola Discovery

Akses terbuka Jurnal SINTA 1

Optimize the position of the distributed generator and capacitor bank in the distributed grid to minimize the generation cost

International Journal of Applied Power Engineering (IJAPE) · Vol. 14 No. 4 (2025) · hlm. 970–979

DOI
10.11591/ijape.v14.i4.pp970-979
ISSN
2722-2624, 2252-8792
Terbit
2025-12-01
Penerbit
Institute of Advanced Engineering and Science
Bahasa
eng
Lisensi
creativecommons.org/licenses/by-sa/4.0

Abstrak

In this paper, we focus on determining the optimal position and size of multi-distributed generators and capacitor banks to minimize the generation cost of a distributed grid. The optimal position and size of distributed generators and capacitor banks are determined using a hybrid of conventional loss sensitivity factor and an improved one. The proposed algorithm has two stages. For each distributed generator, we prioritize its position and size. After that, we find the optimal position and size of the capacitor banks corresponding to this distributed generator installation to minimize the power loss. After considering all distributed generators, the optimal number, position, and size of the distributed generators and capacitor banks are determined based on the minimum generation cost value. This idea is developed in MATLAB and verified via sample distributed grids, including the IEEE-69 bus and IEEE-85 bus. The verifying results are evaluated and analyzed. By comparing those results to those of other methods, the performance of the newly introduced method is proven.

Kata kunci

Jaringan kolaborasi para penulis

6 penulis · 6 tautan kepenulisan bersama · 2 lintas organisasi

Arahkan kursor atau ketuk sebuah nama untuk menyorot rekan penulisnya. Klik dua kali untuk membuka halaman penulis.

  • University of Science and Technology - The University of Da Nang
  • University of Da Nang
  • Afiliasi tidak diketahui
  • Organisasi berbeda
  • Organisasi sama
  • Afiliasi tidak diketahui
  • Garis lebih tebal = lebih banyak artikel bersama · lingkaran lebih besar = lebih banyak artikel
Tampilkan sebagai tabel
Rekan penulisOrganisasiArtikel bersama
Trung Hieu TrinhUniversity of Science and Technology - The University of Da Nang2
Ngọc An LuuUniversity of Da Nang1
Dinh Chung PhanAfiliasi tidak diketahui1
Dinh Truc HaUniversity of Science and Technology - The University of Da Nang1

Afiliasi berasal dari OpenAlex; metadata OAI-PMH jurnal tidak memuatnya. Penulis tanpa ID OpenAlex dicocokkan berdasarkan nama, sehingga dua orang bisa tergabung atau satu orang bisa terpisah.

Sumber metadata: OAI-PMH (metadata jurnal) http://ijape.iaescore.com/index.php/IJAPE/oai, pertama di-harvest 8 Nov 2026, terakhir terlihat 22 Nov 2026.
Metadata asli (oai_dc)
<oai_dc:dc xmlns="http://www.openarchives.org/OAI/2.0/" xmlns:dc="http://purl.org/dc/elements/1.1/" xmlns:oai_dc="http://www.openarchives.org/OAI/2.0/oai_dc/" xmlns:xsi="http://www.w3.org/2001/XMLSchema-instance" xsi:schemaLocation="http://www.openarchives.org/OAI/2.0/oai_dc/  http://www.openarchives.org/OAI/2.0/oai_dc.xsd">
	<dc:title xml:lang="en-US">Optimize the position of the distributed generator and capacitor bank in the distributed grid to minimize the generation cost</dc:title>
	<dc:creator>Luu, Ngoc An</dc:creator>
	<dc:creator>Phan, Dinh Chung</dc:creator>
	<dc:subject xml:lang="en-US">capacitor bank; distributed generator; distributed grid; generation cost; power loss</dc:subject>
	<dc:description xml:lang="en-US">In this paper, we focus on determining the optimal position and size of multi-distributed generators and capacitor banks to minimize the generation cost of a distributed grid. The optimal position and size of distributed generators and capacitor banks are determined using a hybrid of conventional loss sensitivity factor and an improved one. The proposed algorithm has two stages. For each distributed generator, we prioritize its position and size. After that, we find the optimal position and size of the capacitor banks corresponding to this distributed generator installation to minimize the power loss. After considering all distributed generators, the optimal number, position, and size of the distributed generators and capacitor banks are determined based on the minimum generation cost value. This idea is developed in MATLAB and verified via sample distributed grids, including the IEEE-69 bus and IEEE-85 bus. The verifying results are evaluated and analyzed. By comparing those results to those of other methods, the performance of the newly introduced method is proven.</dc:description>
	<dc:publisher xml:lang="en-US">Institute of Advanced Engineering and Science</dc:publisher>
	<dc:contributor xml:lang="en-US"></dc:contributor>
	<dc:date>2025-12-01</dc:date>
	<dc:type>info:eu-repo/semantics/article</dc:type>
	<dc:type>info:eu-repo/semantics/publishedVersion</dc:type>
	<dc:type xml:lang="en-US"></dc:type>
	<dc:format>application/pdf</dc:format>
	<dc:identifier>https://ijape.iaescore.com/index.php/IJAPE/article/view/21725</dc:identifier>
	<dc:identifier>10.11591/ijape.v14.i4.pp970-979</dc:identifier>
	<dc:source xml:lang="en-US">International Journal of Applied Power Engineering (IJAPE); Vol 14, No 4: December 2025; 970-979</dc:source>
	<dc:source>2722-2624</dc:source>
	<dc:source>2252-8792</dc:source>
	<dc:source>10.11591/ijape.v14.i4</dc:source>
	<dc:language>eng</dc:language>
	<dc:relation>https://ijape.iaescore.com/index.php/IJAPE/article/view/21725/13378</dc:relation>
	<dc:rights xml:lang="en-US">Copyright (c) 2025 Ngoc An Luu, Dinh Chung Phan</dc:rights>
	<dc:rights xml:lang="en-US">http://creativecommons.org/licenses/by-sa/4.0</dc:rights>
</oai_dc:dc>