Melola Discovery

← Melola Discovery

Akses terbuka Jurnal SINTA 1

Impact of FACTS Devices in Optimal Generation in Deregulated Power System

International Journal of Applied Power Engineering (IJAPE) · Vol. 4 No. 3 (2015) · hlm. 118–125

DOI
10.11591/ijape.v4.i3.pp118-125
ISSN
2722-2624, 2252-8792
Terbit
2015-12-01
Penerbit
Institute of Advanced Engineering and Science
Bahasa
eng
Lisensi
creativecommons.org/licenses/by-sa/4.0

Abstrak

Since Gencos and Discos compete primarily based on the price in a deregulated market, minimizing the losses or regulating the voltage or controlling the power flow within the rating of power system components such as cables, transformers, transmission lines become extremely difficult. Recent developments in FACTS devices increases the number of constraints and nonlinearity, and henceachieving the optimal solution becomes further complicated. The Optimal Power Flow Problem, determines the best way to operate a power system at any given instant. It solves the power system load flow with an aim to optimize system operating conditions while automatically adjusting control variable settings without violating the system operating constraints. In this paper such constraints based OPF scheme is developed and presented which also incorporates various Flexible AC Transmission Devices. In this work three different types of FACTS devices namely SVC, TCSC, UPFC are separately included into the OPF problem in addition to the conventional constraints that govern an OPF solution. An IEEE 30 bus system is considered and the results obtained for three different loading conditions with three different FACTS devices and their performance are evaluated.

Jaringan kolaborasi para penulis

8 penulis · 9 tautan kepenulisan bersama · 5 lintas organisasi

Arahkan kursor atau ketuk sebuah nama untuk menyorot rekan penulisnya. Klik dua kali untuk membuka halaman penulis.

  • KIIT University
  • Sambalpur University
  • Veer Surendra Sai University of Technology
  • Siksha O Anusandhan University
  • Afiliasi tidak diketahui
  • Organisasi berbeda
  • Organisasi sama
  • Afiliasi tidak diketahui
  • Garis lebih tebal = lebih banyak artikel bersama · lingkaran lebih besar = lebih banyak artikel
Tampilkan sebagai tabel
Rekan penulisOrganisasiArtikel bersama
Sujit Kumar BhuyanKIIT University3
Bhagabat PandaKIIT University2
Atulya Prasad NaikAfiliasi tidak diketahui1
Nakul Charan SahuSiksha O Anusandhan University1
Bhagabata PandaAfiliasi tidak diketahui1
Sarita SamalKIIT University1

Afiliasi berasal dari OpenAlex; metadata OAI-PMH jurnal tidak memuatnya. Penulis tanpa ID OpenAlex dicocokkan berdasarkan nama, sehingga dua orang bisa tergabung atau satu orang bisa terpisah.

Sumber metadata: OAI-PMH (metadata jurnal) http://ijape.iaescore.com/index.php/IJAPE/oai, pertama di-harvest 8 Nov 2026, terakhir terlihat 16 Nov 2026.
Metadata asli (oai_dc)
<oai_dc:dc xmlns="http://www.openarchives.org/OAI/2.0/" xmlns:dc="http://purl.org/dc/elements/1.1/" xmlns:oai_dc="http://www.openarchives.org/OAI/2.0/oai_dc/" xmlns:xsi="http://www.w3.org/2001/XMLSchema-instance" xsi:schemaLocation="http://www.openarchives.org/OAI/2.0/oai_dc/  http://www.openarchives.org/OAI/2.0/oai_dc.xsd">
	<dc:title xml:lang="en-US">Impact of FACTS Devices in Optimal Generation in Deregulated  Power System</dc:title>
	<dc:creator>Gouda, Pramod Kumar</dc:creator>
	<dc:creator>Hota, Prakash Kumar</dc:creator>
	<dc:description xml:lang="en-US">Since Gencos and Discos compete primarily based on the price in a deregulated market, minimizing the losses or regulating the voltage or controlling the power flow within the rating of power system components such as cables, transformers, transmission lines become extremely difficult. Recent developments in FACTS devices increases the number of constraints and nonlinearity, and henceachieving the optimal solution becomes further complicated. The Optimal Power Flow Problem, determines the best way to operate a power system at any given instant. It solves the power system load flow with an aim to optimize system operating conditions while automatically adjusting control variable settings without violating the system operating constraints. In this paper such constraints based OPF scheme is developed and presented which also incorporates various Flexible AC Transmission Devices. In this work three different types of FACTS devices namely SVC, TCSC, UPFC are separately included into the OPF problem in addition to the conventional constraints that govern an OPF solution. An IEEE 30 bus system is considered and the results obtained for three different loading conditions with three different FACTS devices and their performance are evaluated.</dc:description>
	<dc:publisher xml:lang="en-US">Institute of Advanced Engineering and Science</dc:publisher>
	<dc:contributor xml:lang="en-US"></dc:contributor>
	<dc:date>2015-12-01</dc:date>
	<dc:type>info:eu-repo/semantics/article</dc:type>
	<dc:type>info:eu-repo/semantics/publishedVersion</dc:type>
	<dc:type xml:lang="en-US"></dc:type>
	<dc:format>application/pdf</dc:format>
	<dc:identifier>https://ijape.iaescore.com/index.php/IJAPE/article/view/4837</dc:identifier>
	<dc:identifier>10.11591/ijape.v4.i3.pp118-125</dc:identifier>
	<dc:source xml:lang="en-US">International Journal of Applied Power Engineering (IJAPE); Vol 4, No 3: December 2015; 118-125</dc:source>
	<dc:source>2722-2624</dc:source>
	<dc:source>2252-8792</dc:source>
	<dc:source>10.11591/ijape.v4.i3</dc:source>
	<dc:language>eng</dc:language>
	<dc:relation>https://ijape.iaescore.com/index.php/IJAPE/article/view/4837/4143</dc:relation>
	<dc:rights xml:lang="en-US">Copyright (c) 2021 Institute of Advanced Engineering and Science</dc:rights>
	<dc:rights xml:lang="en-US">http://creativecommons.org/licenses/by-sa/4.0</dc:rights>
</oai_dc:dc>