Akses terbuka
Jurnal
SINTA 1
Effect of the bus voltage level on the power system design for microsatellites
International Journal of Applied Power Engineering (IJAPE) · Vol. 11 No. 1 (2022) · hlm. 91–97
ISSN 2722-2624, 2252-8792
Terbit 2022-03-01
Penerbit Institute of Advanced Engineering and Science
Bahasa eng
Abstrak
Each time there is a need for a satellite mission analysis, engineers need to coordinate together the choice of one technology with regard to the other (i.e. solar cells technology, transistors, microcontrollers, and batteries). The process of selecting one technology to another or a component to another is called ‘trade off’. This concept is a hard and situational decision that involves diminishing one quality, of a system or a design in return for gains in other aspects such as weight, performance, speed and so on. The present paper will focus essentially on the use of the 28 V unregulated bus voltage because early satellites, all used, a 14 V unregulated bus voltage. The paper will also show trade-offs made when using the 28 V unregulated bus voltage with different topologies.
Jaringan kolaborasi para penulis
6 penulis ·
9 tautan kepenulisan bersama
· 3 lintas organisasi
Arahkan kursor atau ketuk sebuah nama untuk menyorot rekan penulisnya. Klik dua kali untuk membuka halaman penulis.
Agence Spatiale Algérienne Université des Sciences et de la Technologie d'Oran Mohamed Boudiaf
Organisasi berbeda
Organisasi sama
Afiliasi tidak diketahui
Garis lebih tebal = lebih banyak artikel bersama · lingkaran lebih besar = lebih banyak artikel
Tampilkan sebagai tabel
Afiliasi berasal dari OpenAlex; metadata OAI-PMH jurnal tidak memuatnya. Penulis tanpa ID OpenAlex dicocokkan berdasarkan nama, sehingga dua orang bisa tergabung atau satu orang bisa terpisah.
Sumber metadata: OAI-PMH (metadata jurnal) http://ijape.iaescore.com/index.php/IJAPE/oai, pertama di-harvest 8 Nov 2026, terakhir terlihat 22 Nov 2026.
Metadata asli (oai_dc)
<oai_dc:dc xmlns="http://www.openarchives.org/OAI/2.0/" xmlns:dc="http://purl.org/dc/elements/1.1/" xmlns:oai_dc="http://www.openarchives.org/OAI/2.0/oai_dc/" xmlns:xsi="http://www.w3.org/2001/XMLSchema-instance" xsi:schemaLocation="http://www.openarchives.org/OAI/2.0/oai_dc/ http://www.openarchives.org/OAI/2.0/oai_dc.xsd">
<dc:title xml:lang="en-US">Effect of the bus voltage level on the power system design for microsatellites</dc:title>
<dc:creator>Bekhti, Mohammed</dc:creator>
<dc:creator>Beldjehem, Mohammed</dc:creator>
<dc:creator>Faiza, Arezki</dc:creator>
<dc:subject xml:lang="en-US">battery capacity; battery charge regulator; DC/DC converter; power conditioning module; power distribution module; power system; unregulated bus voltage</dc:subject>
<dc:description xml:lang="en-US">Each time there is a need for a satellite mission analysis, engineers need to coordinate together the choice of one technology with regard to the other (i.e. solar cells technology, transistors, microcontrollers, and batteries). The process of selecting one technology to another or a component to another is called ‘trade off’. This concept is a hard and situational decision that involves diminishing one quality, of a system or a design in return for gains in other aspects such as weight, performance, speed and so on. The present paper will focus essentially on the use of the 28 V unregulated bus voltage because early satellites, all used, a 14 V unregulated bus voltage. The paper will also show trade-offs made when using the 28 V unregulated bus voltage with different topologies.</dc:description>
<dc:publisher xml:lang="en-US">Institute of Advanced Engineering and Science</dc:publisher>
<dc:contributor xml:lang="en-US">Algerian Space Agency / Centre for Satellites Development</dc:contributor>
<dc:date>2022-03-01</dc:date>
<dc:type>info:eu-repo/semantics/article</dc:type>
<dc:type>info:eu-repo/semantics/publishedVersion</dc:type>
<dc:type xml:lang="en-US"></dc:type>
<dc:format>application/pdf</dc:format>
<dc:identifier>https://ijape.iaescore.com/index.php/IJAPE/article/view/20405</dc:identifier>
<dc:identifier>10.11591/ijape.v11.i1.pp91-97</dc:identifier>
<dc:source xml:lang="en-US">International Journal of Applied Power Engineering (IJAPE); Vol 11, No 1: March 2022; 91-97</dc:source>
<dc:source>2722-2624</dc:source>
<dc:source>2252-8792</dc:source>
<dc:source>10.11591/ijape.v11.i1</dc:source>
<dc:language>eng</dc:language>
<dc:relation>https://ijape.iaescore.com/index.php/IJAPE/article/view/20405/12992</dc:relation>
<dc:rights xml:lang="en-US">Copyright (c) 2022 Mohammed Mohammed</dc:rights>
<dc:rights xml:lang="en-US">http://creativecommons.org/licenses/by-sa/4.0</dc:rights>
</oai_dc:dc>
Sitasi dan pengindeksan
Jumlah menurut tiap indeks pada 13 Nov 2026; setiap indeks menghitung sitasi dengan cara berbeda.
OpenAlex juga mencatat karya ini di: crossref.
Sitasi artikel ini
APA 7
Bekhti, M., Beldjehem, M., & Faiza, A. (2022). Effect of the bus voltage level on the power system design for microsatellites. International Journal of Applied Power Engineering (IJAPE), 11(1), 91–97. https://doi.org/10.11591/ijape.v11.i1.pp91-97
Salin
IEEE
M. Bekhti, M. Beldjehem, and A. Faiza, “Effect of the bus voltage level on the power system design for microsatellites,” International Journal of Applied Power Engineering (IJAPE), vol. 11, no. 1, pp. 91–97, 2022, doi: 10.11591/ijape.v11.i1.pp91-97.
Salin
Dibuat dari metadata jurnal; periksa nama penulis sebelum dipakai.