Akses terbuka
Jurnal
SINTA 1
PD characteristics of polymer insulation for inverted-fed drives under sine and square waveforms
International Journal of Applied Power Engineering (IJAPE) · Vol. 14 No. 4 (2025) · hlm. 893–902
ISSN 2722-2624, 2252-8792
Terbit 2025-12-01
Penerbit Institute of Advanced Engineering and Science
Bahasa eng
Abstrak
In recent years, adjustable speed drives power by power electronic converters have caused insulation failure in the electrical motors with stator windings. The repeating impulse voltages produced by IGBTs created insulation reliability problems in the stator winding. Overvoltage can cause partial discharge (PD), which can rapidly result in insulation system failure. To address this issue, IEC standards and technical specifications (TS) necessitate that a PD test on the motor insulation system is done at sinusoidal and square voltages. The PD characteristics obtained are used to evaluate insulation performance, enhancing insulation design. This work focuses on the PD characterization of twisted pair samples using high frequency sine and square waveforms at room temperature. The PD characteristics were investigated at 50 Hz, 1 kHz, 2.4 kHz, and 5 kHz. The result shows that there are fewer PD events with lower PD magnitudes and shorter delay times at higher frequencies. Further, at different temperatures of 30 °C, 60 °C, and 90 °C, the partial discharge inception voltage (PDIV) of twisted pair insulation was investigated using high-frequency sine and square waveforms. The results show that the corona inception voltage (CIV) (kV) decreases as ambient temperature increases. Furthermore, the conditions for PD occurrence in the insulation system were analyzed at higher switching frequencies. The electric field distribution of twisted pairs with a 0 mm air gap was modeled from 50 Hz to 5 kHz switching frequency using COMSOL software.
Jaringan kolaborasi para penulis
10 penulis ·
31 tautan kepenulisan bersama
· 1 lintas organisasi
Arahkan kursor atau ketuk sebuah nama untuk menyorot rekan penulisnya. Klik dua kali untuk membuka halaman penulis.
Puducherry Technological University Indian Institute of Technology Madras Afiliasi tidak diketahui
Organisasi berbeda
Organisasi sama
Afiliasi tidak diketahui
Garis lebih tebal = lebih banyak artikel bersama · lingkaran lebih besar = lebih banyak artikel
Tampilkan sebagai tabel
Afiliasi berasal dari OpenAlex; metadata OAI-PMH jurnal tidak memuatnya. Penulis tanpa ID OpenAlex dicocokkan berdasarkan nama, sehingga dua orang bisa tergabung atau satu orang bisa terpisah.
Sumber metadata: OAI-PMH (metadata jurnal) http://ijape.iaescore.com/index.php/IJAPE/oai, pertama di-harvest 8 Nov 2026, terakhir terlihat 16 Nov 2026.
Metadata asli (oai_dc)
<oai_dc:dc xmlns="http://www.openarchives.org/OAI/2.0/" xmlns:dc="http://purl.org/dc/elements/1.1/" xmlns:oai_dc="http://www.openarchives.org/OAI/2.0/oai_dc/" xmlns:xsi="http://www.w3.org/2001/XMLSchema-instance" xsi:schemaLocation="http://www.openarchives.org/OAI/2.0/oai_dc/ http://www.openarchives.org/OAI/2.0/oai_dc.xsd">
<dc:title xml:lang="en-US">PD characteristics of polymer insulation for inverted-fed drives under sine and square waveforms</dc:title>
<dc:creator>Rao, S. Narasimha</dc:creator>
<dc:creator>Kasinathan, Elanseralathan</dc:creator>
<dc:creator>Sarathi, Ramanujam</dc:creator>
<dc:subject xml:lang="en-US">electric field distribution; high switching frequency; modeling; PRPD; square wave voltage; twisted pair</dc:subject>
<dc:description xml:lang="en-US">In recent years, adjustable speed drives power by power electronic converters have caused insulation failure in the electrical motors with stator windings. The repeating impulse voltages produced by IGBTs created insulation reliability problems in the stator winding. Overvoltage can cause partial discharge (PD), which can rapidly result in insulation system failure. To address this issue, IEC standards and technical specifications (TS) necessitate that a PD test on the motor insulation system is done at sinusoidal and square voltages. The PD characteristics obtained are used to evaluate insulation performance, enhancing insulation design. This work focuses on the PD characterization of twisted pair samples using high frequency sine and square waveforms at room temperature. The PD characteristics were investigated at 50 Hz, 1 kHz, 2.4 kHz, and 5 kHz. The result shows that there are fewer PD events with lower PD magnitudes and shorter delay times at higher frequencies. Further, at different temperatures of 30 °C, 60 °C, and 90 °C, the partial discharge inception voltage (PDIV) of twisted pair insulation was investigated using high-frequency sine and square waveforms. The results show that the corona inception voltage (CIV) (kV) decreases as ambient temperature increases. Furthermore, the conditions for PD occurrence in the insulation system were analyzed at higher switching frequencies. The electric field distribution of twisted pairs with a 0 mm air gap was modeled from 50 Hz to 5 kHz switching frequency using COMSOL software.</dc:description>
<dc:publisher xml:lang="en-US">Institute of Advanced Engineering and Science</dc:publisher>
<dc:contributor xml:lang="en-US"></dc:contributor>
<dc:date>2025-12-01</dc:date>
<dc:type>info:eu-repo/semantics/article</dc:type>
<dc:type>info:eu-repo/semantics/publishedVersion</dc:type>
<dc:type xml:lang="en-US"></dc:type>
<dc:format>application/pdf</dc:format>
<dc:identifier>https://ijape.iaescore.com/index.php/IJAPE/article/view/21114</dc:identifier>
<dc:identifier>10.11591/ijape.v14.i4.pp893-902</dc:identifier>
<dc:source xml:lang="en-US">International Journal of Applied Power Engineering (IJAPE); Vol 14, No 4: December 2025; 893-902</dc:source>
<dc:source>2722-2624</dc:source>
<dc:source>2252-8792</dc:source>
<dc:source>10.11591/ijape.v14.i4</dc:source>
<dc:language>eng</dc:language>
<dc:relation>https://ijape.iaescore.com/index.php/IJAPE/article/view/21114/13371</dc:relation>
<dc:rights xml:lang="en-US">Copyright (c) 2025 S. Narasimha Rao, Elanseralathan Kasinathan, Ramanujam Sarathi</dc:rights>
<dc:rights xml:lang="en-US">http://creativecommons.org/licenses/by-sa/4.0</dc:rights>
</oai_dc:dc>
Sitasi dan pengindeksan
Jumlah menurut tiap indeks pada 13 Nov 2026; setiap indeks menghitung sitasi dengan cara berbeda.
OpenAlex juga mencatat karya ini di: crossref.
Sitasi artikel ini
APA 7
Rao, S. N., Kasinathan, E., & Sarathi, R. (2025). PD characteristics of polymer insulation for inverted-fed drives under sine and square waveforms. International Journal of Applied Power Engineering (IJAPE), 14(4), 893–902. https://doi.org/10.11591/ijape.v14.i4.pp893-902
Salin
IEEE
S. N. Rao, E. Kasinathan, and R. Sarathi, “PD characteristics of polymer insulation for inverted-fed drives under sine and square waveforms,” International Journal of Applied Power Engineering (IJAPE), vol. 14, no. 4, pp. 893–902, 2025, doi: 10.11591/ijape.v14.i4.pp893-902.
Salin
Dibuat dari metadata jurnal; periksa nama penulis sebelum dipakai.