Harmonic Mitigation for Non-Linear Load using TSH Active Power Filter with PID Controller

International Journal of Applied Power Engineering (IJAPE) · Vol. 7 No. 2 (2018) · hlm. 159–165

DOI
10.11591/ijape.v7.i2.pp159-165
ISSN
2722-2624, 2252-8792
Terbit
2018-06-06
Penerbit
Institute of Advanced Engineering and Science
Bahasa
eng
Lisensi
creativecommons.org/licenses/by-sa/4.0

Abstrak

Electronic equipments, widely used in present living era, required to have improved power quality. When such type of equipments are connected to electric supply distribution system, they introduce non sinusoidal effect in the line current because of their non-linear relationship in voltage and current. Moreover, harmonics in the line current are also produced. With constantly growing imploration of such type of nonlinear equipments at a large scale, harmonic distortions in line current have become a significant crunch. This required some methods involving the reduction of harmonics in the line current as well as Power Factor Improvement/Correction. The primary goal of this proposed work is to reduce the harmonics produced in line current and to improve power quality of non-linear load by designing a converter with parallel processing scheme, named TSH Active power filter (Transformer less shunt active power filter) with PID controller. Here a separate dc source is employed to supply the shunt connected converter, a voltage source inverter, to remove the requirement of bulky transformer at supply end. This paper depicted the process of reduction of total harmonic distortion (THD), generated due to nonlinear characteristics of load and power factor improvement by shunt compensation. The proposed designs are modeled and simukated using Matlab simulation software.

Jaringan kolaborasi para penulis

4 penulis · 5 tautan kepenulisan bersama

Arahkan kursor atau ketuk sebuah nama untuk menyorot rekan penulisnya. Klik dua kali untuk membuka halaman penulis.

  • Jaipur National University
  • Organisasi berbeda
  • Organisasi sama
  • Afiliasi tidak diketahui
  • Garis lebih tebal = lebih banyak artikel bersama · lingkaran lebih besar = lebih banyak artikel
Tampilkan sebagai tabel
Rekan penulisOrganisasiArtikel bersama
Sudhir Kumar SharmaJaipur National University2

Afiliasi berasal dari OpenAlex; metadata OAI-PMH jurnal tidak memuatnya. Penulis tanpa ID OpenAlex dicocokkan berdasarkan nama, sehingga dua orang bisa tergabung atau satu orang bisa terpisah.

Sumber metadata: OAI-PMH (metadata jurnal) http://ijape.iaescore.com/index.php/IJAPE/oai, pertama di-harvest 8 Nov 2026, terakhir terlihat 22 Nov 2026.
Metadata asli (oai_dc)
<oai_dc:dc xmlns="http://www.openarchives.org/OAI/2.0/" xmlns:dc="http://purl.org/dc/elements/1.1/" xmlns:oai_dc="http://www.openarchives.org/OAI/2.0/oai_dc/" xmlns:xsi="http://www.w3.org/2001/XMLSchema-instance" xsi:schemaLocation="http://www.openarchives.org/OAI/2.0/oai_dc/  http://www.openarchives.org/OAI/2.0/oai_dc.xsd">
	<dc:title xml:lang="en-US">Harmonic Mitigation for Non-Linear Load using TSH Active Power Filter with PID Controller</dc:title>
	<dc:creator>Sinha, Garima</dc:creator>
	<dc:creator>Goswami, Pankaj kumar</dc:creator>
	<dc:creator>Sharma, Sudhir kr.</dc:creator>
	<dc:description xml:lang="en-US">Electronic equipments, widely used in present living era, required to have improved power quality. When such type of equipments are connected to electric supply distribution system, they introduce non sinusoidal effect in the line current because of their non-linear relationship in voltage and current. Moreover, harmonics in the line current are also produced. With constantly growing imploration of such type of nonlinear equipments at a large scale, harmonic distortions in line current have become a significant crunch. This required some methods involving the reduction of harmonics in the line current as well as Power Factor Improvement/Correction. The primary goal of this proposed work is to reduce the harmonics produced in line current and to improve power quality of non-linear load by designing a converter with parallel processing scheme, named TSH Active power filter (Transformer less shunt active power filter) with PID controller. Here a separate dc source is employed to supply the shunt connected converter, a voltage source inverter, to remove the requirement of bulky transformer at supply end. This paper depicted the process of reduction of total harmonic distortion (THD), generated due to nonlinear characteristics of load and power factor improvement by shunt compensation. The proposed designs are modeled and simukated using Matlab simulation software.</dc:description>
	<dc:publisher xml:lang="en-US">Institute of Advanced Engineering and Science</dc:publisher>
	<dc:contributor xml:lang="en-US"></dc:contributor>
	<dc:date>2018-06-06</dc:date>
	<dc:type>info:eu-repo/semantics/article</dc:type>
	<dc:type>info:eu-repo/semantics/publishedVersion</dc:type>
	<dc:type xml:lang="en-US"></dc:type>
	<dc:format>application/pdf</dc:format>
	<dc:identifier>https://ijape.iaescore.com/index.php/IJAPE/article/view/12684</dc:identifier>
	<dc:identifier>10.11591/ijape.v7.i2.pp159-165</dc:identifier>
	<dc:source xml:lang="en-US">International Journal of Applied Power Engineering (IJAPE); Vol 7, No 2: August 2018; 159-165</dc:source>
	<dc:source>2722-2624</dc:source>
	<dc:source>2252-8792</dc:source>
	<dc:source>10.11591/ijape.v7.i2</dc:source>
	<dc:language>eng</dc:language>
	<dc:relation>https://ijape.iaescore.com/index.php/IJAPE/article/view/12684/12146</dc:relation>
	<dc:rights xml:lang="en-US">Copyright (c) 2021 Institute of Advanced Engineering and Science</dc:rights>
	<dc:rights xml:lang="en-US">http://creativecommons.org/licenses/by-sa/4.0</dc:rights>
</oai_dc:dc>