Abstrak

This paper studied the reactive power control of the voltage source converters based high-voltage direct current system (VSC-HVDC). PI (proportional & integration) controller was used in this work to enhance the dynamic response of the system. Gravitational search algorithm (GSA) and sine cosine algorithm (SCA) are used to get optimal parameters of the PI controller. GSA algorithm is based on the gravity law for Newton while SCA depends on mathematical model based on cosine and sine functions. These algorithms have an efficient global Search capability. The VSC-HVDC is exposed to different disturbances for checking the controller robustness. First disturbance was applying three phase faults on the system. While the second one was applying a step change in AC voltage. Finally, Applying step change in regulators reference values. Simulation results proved the controller superiority also verified the enhancement of the system dynamic response.

Jaringan kolaborasi para penulis

18 penulis · 33 tautan kepenulisan bersama · 9 lintas organisasi

Arahkan kursor atau ketuk sebuah nama untuk menyorot rekan penulisnya. Klik dua kali untuk membuka halaman penulis.

  • Ain Shams University
  • The Future University
  • Aswan University
  • Kafrelsheikh University
  • Menoufia University
  • Afiliasi tidak diketahui
  • Organisasi berbeda
  • Organisasi sama
  • Afiliasi tidak diketahui
  • Garis lebih tebal = lebih banyak artikel bersama · lingkaran lebih besar = lebih banyak artikel
Tampilkan sebagai tabel
Rekan penulisOrganisasiArtikel bersama
Mahmoud A. SolimanAin Shams University2
Othman A. M. OmarAin Shams University2
Mahmoud M. El-SharkawyAin Shams University2
Said Fouad MekhamerThe Future University1
R. H. ShehataAin Shams University1
Mostafa A. Al-GabalawyThe Future University1
Rabab M. I. El-HassaniAin Shams University1
Mina N. AminAin Shams University1
Hany Mohamed HasanienAin Shams University1
Ragab Abdelaziz El-SehiemyKafrelsheikh University1
Ahmed R. AdlyAfiliasi tidak diketahui1
Mahmoud A. ElsaddMenoufia University1
Ahmad EidAswan University1
Mostafa M. DardeerAswan University1

Afiliasi berasal dari OpenAlex; metadata OAI-PMH jurnal tidak memuatnya. Penulis tanpa ID OpenAlex dicocokkan berdasarkan nama, sehingga dua orang bisa tergabung atau satu orang bisa terpisah.

Sumber metadata: OAI-PMH (metadata jurnal) http://ijape.iaescore.com/index.php/IJAPE/oai, pertama di-harvest 8 Nov 2026, terakhir terlihat 22 Nov 2026.
Metadata asli (oai_dc)
<oai_dc:dc xmlns="http://www.openarchives.org/OAI/2.0/" xmlns:dc="http://purl.org/dc/elements/1.1/" xmlns:oai_dc="http://www.openarchives.org/OAI/2.0/oai_dc/" xmlns:xsi="http://www.w3.org/2001/XMLSchema-instance" xsi:schemaLocation="http://www.openarchives.org/OAI/2.0/oai_dc/  http://www.openarchives.org/OAI/2.0/oai_dc.xsd">
	<dc:title xml:lang="en-US">Reactive power control to enhance the VSC-HVDC system performance under faulty and normal conditions</dc:title>
	<dc:creator>Ghayad, Mohamed S.</dc:creator>
	<dc:creator>Badra, Niveen M.</dc:creator>
	<dc:creator>Abdelaziz, Almoataz Y.</dc:creator>
	<dc:creator>Attia, Mahmoud A.</dc:creator>
	<dc:description xml:lang="en-US">This paper studied the reactive power control of the voltage source converters based high-voltage direct current system (VSC-HVDC). PI (proportional &amp;amp; integration) controller was used in this work to enhance the dynamic response of the system. Gravitational search algorithm (GSA) and sine cosine algorithm (SCA) are used to get optimal parameters of the PI controller. GSA algorithm is based on the gravity law for Newton while SCA depends on mathematical model based on cosine and sine functions. These algorithms have an efficient global Search capability. The VSC-HVDC is exposed to different disturbances for checking the controller robustness. First disturbance was applying three phase faults on the system. While the second one was applying a step change in AC voltage. Finally, Applying step change in regulators reference values. Simulation results proved the controller superiority also verified the enhancement of the system dynamic response.</dc:description>
	<dc:publisher xml:lang="en-US">Institute of Advanced Engineering and Science</dc:publisher>
	<dc:contributor xml:lang="en-US"></dc:contributor>
	<dc:date>2019-08-01</dc:date>
	<dc:type>info:eu-repo/semantics/article</dc:type>
	<dc:type>info:eu-repo/semantics/publishedVersion</dc:type>
	<dc:type xml:lang="en-US"></dc:type>
	<dc:format>application/pdf</dc:format>
	<dc:identifier>https://ijape.iaescore.com/index.php/IJAPE/article/view/15809</dc:identifier>
	<dc:identifier>10.11591/ijape.v8.i2.pp145-158</dc:identifier>
	<dc:source xml:lang="en-US">International Journal of Applied Power Engineering (IJAPE); Vol 8, No 2: August 2019; 145-158</dc:source>
	<dc:source>2722-2624</dc:source>
	<dc:source>2252-8792</dc:source>
	<dc:source>10.11591/ijape.v8.i2</dc:source>
	<dc:language>eng</dc:language>
	<dc:relation>https://ijape.iaescore.com/index.php/IJAPE/article/view/15809/12841</dc:relation>
	<dc:rights xml:lang="en-US">Copyright (c) 2021 Institute of Advanced Engineering and Science</dc:rights>
	<dc:rights xml:lang="en-US">http://creativecommons.org/licenses/by-sa/4.0</dc:rights>
</oai_dc:dc>